NextSDS Logo
EP

EPISOL RM C-COMPONENT

NO SIGNAL WORD vast SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
EPISOL RM C-COMPONENT

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Component van epoxy mortel systeem voor industriel gebruik.

Overview

EPISOL RM C-COMPONENT is a vast substance commonly used component van epoxy mortel systeem voor industriel gebruik..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

N.V. RESIPLAST S.A.

manufacturer

Gulkenrodestraat 3 B-2160 Wommelgem - BELGIE

BE

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Alpha quartz.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Kwartszanden/granulaten
EC: 238-878-4
14808-60-7 80% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

geen bijzondere eerstehulpmaatregelen; eventueel in open lucht brengen en een arts raadplegen.

Symptoms:

hoestbuien en / of ademnood

Skin Contact

geen bijzondere eerstehulpmaatregelen nodig.

Eye Contact

overvloedig met water spoelen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
vast
Critical Property
Physical State Data
solid
State Under Standard Conditions
Not available
Appearance
vast
Colour
wit-grijs-geel
Colour Intensity
Not available
Form
Not available
Odor
geen
Odor Threshold
Not available
Ph
n.v.t.
Melting Point
ca 1.580 C BS 523
Critical Property
Boiling Point
ca 2.200 C DIN 51751
Critical Property
Flash Point
niet van toepassing
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
n.v.t.
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
ca 2,6 g/cm bij 20 C ISO 2811-2
Critical Property
Flammability
Not available
Upper Explosive Limit
n.v.t.
Lower Explosive Limit
n.v.t.
Explosive Limits
Not available
Auto Ignition Temperature
n.v.t.
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
onoplosbaar
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
n.v.t.
Kinematic Viscosity
n.v.t.
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Voorzie aangepaste stofafzuiging en luchtfiltering op de plaats waar stof kan ontwikkeld worden.

Eye Protection

Het dragen van een stofbril met zijbescherming wordt aanbevolen in geval van blootstelling boven de reglementaire norm.

Skin/Body Protection

Draag geschikte beschermende arbeidskleding. Verwijder en was bevuilde

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for EPISOL RM C-COMPONENT?

The signal word for this substance is "no signal word".

What is the physical form of EPISOL RM C-COMPONENT?

EPISOL RM C-COMPONENT is a vast appearing as vast with wit-grijs-geel color. It has geen odor.

What is EPISOL RM C-COMPONENT used for?

Component van epoxy mortel systeem voor industriel gebruik.

What is the melting point of EPISOL RM C-COMPONENT?

The melting point is ca 1.580 C BS 523 and the boiling point is ca 2.200 C DIN 51751.