NextSDS Logo
EP

EPISOL FLOORLINE 1/2 C-COMPONENT

NO SIGNAL WORD vast SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
EPISOL FLOORLINE 1/2 C-COMPONENT

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Component van epoxy gietmortel systeem voor industriel gebruik.

Overview

EPISOL FLOORLINE 1/2 C-COMPONENT is a vast substance commonly used component van epoxy gietmortel systeem voor industriel gebruik..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

N.V. RESIPLAST S.A. company logo - Safety Data Sheet supplier organization

N.V. RESIPLAST S.A.

manufacturer

๐Ÿ“

Gulkenrodestraat 3 B-2160 Wommelgem - BELGIE

๐ŸŒ

BE

๐Ÿ“ 

+ 32-(0)3-322.63.80

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+ 32-(0)3-320.02.11

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Alpha quartz.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Alpha quartz
EC: 238-878-4
14808-60-7 80% โš ๏ธ Hazardous

Composition Notes

Relevante R-zinnen : zie rubriek nr. 16

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

geen bijzondere eerstehulpmaatregelen; eventueel in open lucht brengen en een arts raadplegen.

Symptoms:

hoestbuien en / of ademnood.

๐Ÿ–๏ธ Skin Contact

geen bijzondere eerstehulpmaatregelen nodig.

๐Ÿ‘๏ธ Eye Contact

overvloedig met water spoelen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
vast
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
vast
๐ŸŽจ Colour
wit-grijs-geel
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
geen
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
n.v.t.
๐ŸงŠ Melting Point
ca 1.580 C BS 523
Critical Property
๐Ÿ’จ Boiling Point
ca 2.200 C DIN 51751
Critical Property
๐Ÿ”ฅ Flash Point
niet van toepassing
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
n.v.t.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
ca 2,6 g/cm bij 20 C ISO 2811-2
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
n.v.t.
๐Ÿ“Š Lower Explosive Limit
n.v.t.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
n.v.t.
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
onoplosbaar
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
n.v.t.
๐Ÿ“Š Kinematic Viscosity
n.v.t.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Voorzie aangepaste stofafzuiging en luchtfiltering op de plaats waar stof kan ontwikkeld worden.

๐Ÿ‘๏ธ Eye Protection

Het dragen van een stofbril met zijbescherming wordt aanbevolen in geval van blootstelling boven de reglementaire norm.

๐Ÿฆบ Skin/Body Protection

Draag geschikte beschermende arbeidskleding. Verwijder en was bevuilde

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for EPISOL FLOORLINE 1/2 C-COMPONENT?

The signal word for this substance is "no signal word".

What is the physical form of EPISOL FLOORLINE 1/2 C-COMPONENT?

EPISOL FLOORLINE 1/2 C-COMPONENT is a vast appearing as vast with wit-grijs-geel color. It has geen odor.

What is EPISOL FLOORLINE 1/2 C-COMPONENT used for?

Component van epoxy gietmortel systeem voor industriel gebruik.

What is the melting point of EPISOL FLOORLINE 1/2 C-COMPONENT?

The melting point is ca 1.580 C BS 523 and the boiling point is ca 2.200 C DIN 51751.