Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER
- Product Code
- 7465 / 7466
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Sigma Coatings BV
manufacturer
Amsterdamseweg 14 1422 AD Uithoorn
+31297541911
Emergency Contacts
Emergency Contact
+31204075210
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| POLYAMIDE EPOXY ADDUCT | --- | 10 - 25% | No |
| xylcen EC: 215-535-7 | 1330-20-7 | 10 - 25% | Yes |
| 2-methylpropaun-1-ol EC: 201-148-0 | 78-83-1 | 10 - 25% | Yes |
| ethylbenzne EC: 202-849-4 | 100-41-4 | 2.5 - 10% | Yes |
| 2,4.6-TRI(DIMETHYLAMINOMETHYL) FENOL EC: 202-013-9 | 90-72-2 | 2.5 - 10% | Yes |
Notes
Zle voor componenten met een wettelijke grenswaarde (MAC) hoofdstuk 8.
First Aid Measures
Emergency procedures for chemical exposure incidents
Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige bedeming toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medische advices inwinnen.
Verontreinigde kleding onmiddellijk uitbrekken. De huid grondig wassen met water en zcep of een erkende huidreiniger.
Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlensen uitdoen. Medisch advices inwinnen.
Bij inslikken direkt arts raadplegen. Het slachtoffter laten rusten.
Immediate Medical Attention
Als de zickteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingroepen. Bij inslikken direkt arts raadplegen. Bij bewusteloosheid medisch advies inwinnen.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
SIGMACOVER 256/435/456/522 HARDENER
---
SIGMACOVER 256/435/456/522 HARDENER
---
SIGMACOVER 256/435/456/522 HARDENER
---
SIGMACOVER 256/435/456/522 HARDENER
---
SIGMACOVER 256/435/456/522 HARDENER
---
SIGMACOVER CM COATING/MIO/PRIMER HARDENER
---
SIGMACOVER CM COATING/MIO/PRIMER HARDENER
---
SIGMACOVER CM COATING/MIO/PRIMER HARDENER
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation systems must be present in spray booths to control spray particles and solvent vapors. Minimum ventilation air required for 1 liter product to reach MAC: 2,653 m/l. To reach 10% OEG: 116 m/l.
For longer or repeated contact, safety gloves must be used.
Wearing chemical-resistant safety glasses or sealed glasses is mandatory.
If workers are in a spray booth, ventilation must be present for spray particles and solvent vapors. In these circumstances, they must wear a fresh-air hood during the spraying process until the concentration has dropped below the MAC value. A P2A2 half-face combination mask is also specified.
Personnel must wear protective clothing. Work clothing should not consist of textiles that exhibit dangerous melting behavior in case of fire. Wearing antistatic shoes is mandatory.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT RELATED MATERIAL
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER?
The signal word is na: r-phrases.
What is the physical form of SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER?
SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER is a viskeus . It has weinig zoals amines odor.