NextSDS Logo
SI

SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER

NA: R-PHRASES viskeus SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER
Product Code
7465 / 7466

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

na: r-phrases

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • Spuitnevel niet inademen.
  • Bij aanraking met de ogen ommiddellijk met overvloedig water afspoelen en deskundig medisch advies inwinnen.
  • Drug geschikte beschermende kleding, handschoenen en een beschermingsmiddel voor de ogen/het gezicht.
  • Bij ontoereikende ventilatie een geschikte adembescherming dragen.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma Coatings BV

manufacturer

๐Ÿ“

Amsterdamseweg 14 1422 AD Uithoorn

๐ŸŒ

NL

๐Ÿ“ž

+31297541911

๐Ÿ“ 

+31297541050

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+31204075210

๐ŸŒ

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
POLYAMIDE EPOXY ADDUCT N/A 10-25% โœ“ Non-hazardous
xylcen
EC: 215-535-7
1330-20-7 10-25% โš ๏ธ Hazardous
2-methylpropaun-1-ol
EC: 201-148-0
78-83-1 10-25% โš ๏ธ Hazardous
ethylbenzne
EC: 202-849-4
100-41-4 2.5-10% โš ๏ธ Hazardous
2,4.6-TRI(DIMETHYLAMINOMETHYL) FENOL
EC: 202-013-9
90-72-2 2.5-10% โš ๏ธ Hazardous

Composition Notes

Zle voor componenten met een wettelijke grenswaarde (MAC) hoofdstuk 8.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige bedeming toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medische advices inwinnen.

๐Ÿ–๏ธ Skin Contact

Verontreinigde kleding onmiddellijk uitbrekken. De huid grondig wassen met water en zcep of een erkende huidreiniger.

๐Ÿ‘๏ธ Eye Contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlensen uitdoen. Medisch advices inwinnen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Bij inslikken direkt arts raadplegen. Het slachtoffter laten rusten.

๐Ÿšจ Immediate Medical Attention Required

Als de zickteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingroepen. Bij inslikken direkt arts raadplegen. Bij bewusteloosheid medisch advies inwinnen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Lower Explosive Limit
1.08 % (V)
๐Ÿ’จ Boiling Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Solubility In Water
te verwaarlozen
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿงช Ph
Not available
๐Ÿ“Š Auto Ignition Temperature
> 430 C
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Physical State Data
liquid
๐Ÿงช Physical State
viskeus
Critical Property
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Explosive Limits
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ“Š Colour Intensity
Not available
โš–๏ธ Density
0.91 g/cm3
Critical Property
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ“Š Dynamic Viscosity
400 mPa.s bij 23 C
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ”ฅ Flash Point
29.0 C
Critical Property
๐Ÿ“Š Form
viskeus
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ“Š Properties Status
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ‘ƒ Odor
weinig zoals amines

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation systems must be present in spray booths to control spray particles and solvent vapors. Minimum ventilation air required for 1 liter product to reach MAC: 2,653 m/l. To reach 10% OEG: 116 m/l.

๐Ÿงค Hand Protection

For longer or repeated contact, safety gloves must be used.

๐Ÿ‘๏ธ Eye Protection

Wearing chemical-resistant safety glasses or sealed glasses is mandatory.

๐Ÿ˜ท Respiratory Protection

If workers are in a spray booth, ventilation must be present for spray particles and solvent vapors. In these circumstances, they must wear a fresh-air hood during the spraying process until the concentration has dropped below the MAC value. A P2A2 half-face combination mask is also specified.

๐Ÿฆบ Skin/Body Protection

Personnel must wear protective clothing. Work clothing should not consist of textiles that exhibit dangerous melting behavior in case of fire. Wearing antistatic shoes is mandatory.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1263

๐Ÿ“ฆ Proper Shipping Name

PAINT RELATED MATERIAL

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER?

The signal word for this substance is "na: r-phrases".

What is the physical form of SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER?

SIGMACOVER 256/435/456/522 (SIGMACOVER CM MIO/COATING/PRIMER / SIGMA CM MIO/COATING / SIGMARITE SEALER) HARDENER is a viskeus . It has weinig zoals amines odor.