NextSDS Logo
ZE

ZEP 2000 NEW

DANGER Aerosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ZEP 2000 NEW
Product Code
41640001

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
4TW1-N0VG-EV3K-SHE8

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Smeermiddel

Overview

ZEP 2000 NEW commonly used smeermiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Skin Irr. Category 2 H315
Eye Dam. Category 1 H318
STOT SE Category 3 H336
Asp. Tox. Category 1 H304
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol.
  • H229: Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H318: Veroorzaakt ernstig oogletsel.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P261: Inademing van stof/rook/gas/nevel/damp/spuitnevel vermijden.
  • P305+P351+P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P310: Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 C/122 F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

ZEP ITALIA SRL company logo - Safety Data Sheet supplier organization

ZEP ITALIA SRL

manufacturer

๐Ÿ“

Piazzale Luigi Cadorna, 2 - Milano - (MI) 20123 Milano (MI) - Italy; Via Nettunense Km. 25.000 04011 Aprilia (LT) - Italy

๐ŸŒ

IT

๐Ÿ“ž

+39.06.926691

๐Ÿ“ 

+39.06.92747061

๐ŸŒ www.zep.it

ZEP Industries BV

manufacturer

๐Ÿ“

Vierlinghweg 30 4612 PN Bergen op Zoom The Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+ 31 164 250 100

๐Ÿ“ 

+ 31 164 266 710

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Nationaal Vergiften Informatie Centrum

๐Ÿ“ž

030 - 2748888

๐ŸŒ

NL

๐Ÿ’ก

(Uitsluitend bestemd voor behandelend arts bij accidentele vergiftiging)

Antigifcentrum

๐Ÿ“ž

070245245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Koolwaterstoffen, C6-C7, n-alkanen, iso-alkanen, cyclische verbindingen, <5% n-hexaan N/A Not specified โš ๏ธ Hazardous
propaan
EC: 200-827-9
74-98-6 Not specified โš ๏ธ Hazardous
butaan
EC: 203-448-7
106-97-8 Not specified โš ๏ธ Hazardous
isobutaan
EC: 200-857-2
75-28-5 Not specified โš ๏ธ Hazardous
calciumdihydroxide
EC: 215-137-3
1305-62-0 Not specified โš ๏ธ Hazardous
Amines, C12-18-(even numbered) and C18-(unsaturated) alkyl
EC: 701-068-0
2156592-58-2 Not specified โš ๏ธ Hazardous

Additional Information

Aanvullende indicaties: VERORDENING (EG) Nr. 648/2004 betreffende detergentia. De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Bij bewusteloosheid ligging en vervoer in stabiele zijligging.

๐Ÿ–๏ธ Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen. Onmiddellijk met water afwassen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Onmiddellijk deskundig medisch advies inwinnen.

๐Ÿšจ Immediate Medical Attention Required

Geen verdere relevante informatie verkrijgbaar.

Medical Treatment

Geen verdere relevante informatie verkrijgbaar.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Aerosol
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Doorschijnend
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Aerosol
๐Ÿ‘ƒ Odor
Karakteristiek
๐Ÿ“Š Odor Threshold
Niet bepaald.
๐Ÿงช Ph
Niet bepaald.
๐ŸงŠ Melting Point
Niet bepaald.
Critical Property
๐Ÿ’จ Boiling Point
-44 C
Critical Property
๐Ÿ”ฅ Flash Point
-97 C
Critical Property
๐Ÿ“Š Freezing Point
Niet bepaald.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Niet bruikbaar.
๐Ÿ’จ Vapor Pressure
3500 hPa
๐Ÿ“Š Vapor Density
Niet bepaald.
๐Ÿ“Š Relative Density
Niet bepaald.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,704 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Niet bruikbaar.
๐Ÿ“Š Upper Explosive Limit
10,9 Vol %
๐Ÿ“Š Lower Explosive Limit
1,5 Vol %
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Het produkt ontbrandt niet uit zichzelf.
๐Ÿ“Š Decomposition Temperature
Niet bepaald.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Niet bepaald.
๐Ÿ“Š Solubility In Water
Niet oplosbaar.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
452,7 g/l
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Niet bepaald.
๐Ÿ“Š Kinematic Viscosity
Niet bepaald.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Geen aanvullende gegevens. Zie 7.

๐Ÿงค Hand Protection

Veiligheidshandschoenen De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vr het gebruik worden getest. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee. De vastgestelde penetratietijden volgens EN 16523-1:2015 werden niet onder de praktijkvoorwaarden bepaald. Er wordt bijgevolg een maximale draagtijd aanbevolen die overeenkomt met 50 % van de opgegeven penetratietijd. Niet geschikt zijn handschoenen uit de volgende materialen: Handschoenen uit dikke stof

๐Ÿ˜ท Respiratory Protection

Adembescherming enkel bij arosol- of nevelvorming. Filter AX Filter A

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1950

๐Ÿ“ฆ Proper Shipping Name

SPUITBUSSEN, MILIEUGEVAARLIJK

โš ๏ธ Transport Hazard Class

2.1

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ZEP 2000 NEW?

The signal word for this substance is "danger".

What is the physical form of ZEP 2000 NEW?

ZEP 2000 NEW is a aerosol with doorschijnend color. It has karakteristiek odor.

What is ZEP 2000 NEW used for?

Smeermiddel

What are the hazard statements for ZEP 2000 NEW?

This substance has 7 hazard statements: H222: Zeer licht ontvlambare aerosol. H229: Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H318: Veroorzaakt ernstig oogletsel. H336: Kan slaperigheid of duizeligheid veroorzaken. H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt. H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of ZEP 2000 NEW?

The melting point is Niet bepaald. and the boiling point is -44 C.