NextSDS Logo
Safety Data Sheet NL

PLURIOL E 4000 E

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PLURIOL E 4000 E

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

B

BASF BELGIUM N.V./S.A.

manufacturer

HAMOIRLAAN 14/14, AVENUE HAMOIR, 1180 BRUSSEL/BRUXELLES

02/373.25.83

Emergency Contacts

Emergency Contact

02/373.27.77

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Polyethyleenglycol

Chemical Name CAS Number Concentration Hazardous
Polyethyleenglycol --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Met water en zeep wassen. Gesmolten massa: Na contact met gesmolten product snel met koud water afkoelen. Gestold product niet van de huid trekken. Verbrandingen door gesmolten materiaal moeten klinisch behandeld worden. Arts bezoeken.

Eye contact

15 minuten met opengesperde oogleden d.m.v. stromend water grondig spoelen.

Ingestion

Mond spoelen en daarna rijkelijk water drinken.

Immediate Medical Attention

Verbrandingen door gesmolten materiaal moeten klinisch behandeld worden. Arts bezoeken.

Medical Treatment

Behandeling van de symptomen (verwijderen van de verontreinigende stof, controle van vitale functies)

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

verneveld water, droge blusmiddelen, schuim, kooldioxide (CO2)

Specific hazards

Bij brand kan (kunnen) vrijkomen: gassen/dampen. Gevaar hangt van de brandende stoffen en de brandomstandigheden af.

Firefighter Protection

Draag bij brand een onafhankelijk ademhalingsapparaat met persluchtcylinder.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Het product mag niet zonder voorbehandeling (biologische waterzuiveringsinstallatie) in waterlopen terechtkomen.

Cleanup methods

Droog opnemen en als afval verwerken.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geen bijzondere maatregelen vereist.

Storage

In goed gesloten verpakking op een droge en koele plaats bewaren. Gesmolten massa tegen temperaturen boven 70 °C beschermen.

Fire prevention

Maatregelen treffen tegen electrostatische opladingen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Aanvullende aanwijzingen voor inrichting technische installaties (zie paragraaf 7)

Hands

beschermende handschoenen

Eyes

beschermbril

Skin/Body

gesloten werkkleding

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
gestolde massa
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
wit
Colour Intensity
---
Form
gestolde massa
Odor
producteigen
Odor Threshold
---
Ph
ca. 7
Melting Point
ca. 55 °C
Boiling Point
---
Flash Point
>100 °C
Freezing Point
ca. 43 C
Softening Point
---
Solidification Point
ca. 43 °C
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 1.1 g/cm³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
>200 °C
Decomposition Temperature
---
Solubility
oplosbaar in: alcoholen, aromatische koolwaterstoffen
Partition Coefficient
---
Solubility In Water
onbegrensd
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
80-130 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Geen bij normale verwerking.

Avoid

Tegen vocht beschermen.

Decomposition

Geen bij normale verwerking.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Moet met inachtneming van de plaatselijke voorschriften b.v. naar een geschikte deponie of een geschikte verbrandingsinstallatie worden afgevoerd.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Classificering volgens EG-richtlijnen: niet aanduidingsplichtig

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PLURIOL E 4000 E?

The signal word is no signal word.

What is the physical form of PLURIOL E 4000 E?

PLURIOL E 4000 E is a gestolde massa with wit color. It has producteigen odor.

What is the solubility of PLURIOL E 4000 E?

oplosbaar in: alcoholen, aromatische koolwaterstoffen

What is the melting point of PLURIOL E 4000 E?

The melting point is ca. 55 °C .