NextSDS Logo
UR

UREUM 40%

NO SIGNAL WORD vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
UREUM 40%

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrieel gebruik, Beroepsmatig gebruik
Uses Advised Against
Op dit ogenblik worden geen ontraden gebruiken gedentificeerd.

Overview

UREUM 40% commonly used industrieel gebruik, beroepsmatig gebruik.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Brenntag N.V.

distributor

๐Ÿ“

Nijverheidslaan 38 BE 8540 Deerlijk

๐ŸŒ

BE

๐Ÿ“ž

+32 (0)56 77 6944

๐Ÿ“ 

+32 (0)56 77 5711

Brenntag Nederland B.V.

distributor

๐Ÿ“

Donker Duyvisweg 44 NL 3316 BM Dordrecht

๐ŸŒ

NL

๐Ÿ“ž

+31 (0)78 65 44 944

๐Ÿ“ 

+31 (0)78 65 44 919

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum - Brussel

๐Ÿ“ž

+32(0)70/245.245

๐ŸŒ

BE

National Poisoning Information Center - Bilthoven

๐Ÿ“ž

+31(0)88 755 8000

๐ŸŒ

NL

๐Ÿ’ก

Only for the purpose of informing medical personnel in cases of acute intoxications

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Waterige oplossing

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
ureum
EC: 200-315-5
57-13-6 10-50% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Overbrengen naar de frisse lucht. Indien symptomen aanhouden, een arts raadplegen.

๐Ÿ–๏ธ Skin Contact

Met zeep en water wassen. Indien symptomen aanhouden, een arts raadplegen.

๐Ÿ‘๏ธ Eye Contact

Grondig spoelen met veel water, ook onder de oogleden. Indien symptomen aanhouden, een arts raadplegen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Mond reinigen met water en daarna veel water drinken. Nooit een bewusteloos persoon laten drinken (of eten). Indien symptomen aanhouden, een arts raadplegen.

Medical Treatment

Symptomatisch behandelen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
vloeibaar
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
kleurloos
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
vloeibaar
๐Ÿ‘ƒ Odor
zwak, ammoniakaal
๐Ÿ“Š Odor Threshold
Geen gegevens beschikbaar
๐Ÿงช Ph
circa 8,9 (20 C) 10% oplossing circa 10 (20 C) 50% oplossing
๐ŸงŠ Melting Point
circa 0 C 10% oplossing circa -11,5 C 50% oplossing
Critical Property
๐Ÿ’จ Boiling Point
circa 100 C 10% oplossing 106 - 110 C 50% oplossing
Critical Property
๐Ÿ”ฅ Flash Point
Niet van toepassing
Critical Property
๐Ÿ“Š Freezing Point
circa 0 C 10% oplossing circa -11,5 C 50% oplossing
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Geen gegevens beschikbaar
๐Ÿ’จ Vapor Pressure
circa 23 hPa (20 C) 25% oplossing circa 64 hPa (40 C) 25% oplossing
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Geen gegevens beschikbaar
๐Ÿ“Š Bulk Density
Geen gegevens beschikbaar
โš–๏ธ Density
circa 1,023 g/cm3 (20 C) 10% oplossing circa 1,14 g/cm3 (20 C) 50% oplossing 1,09 g/cm3 (20 C) 30% 1,11 g/cm3 (20 C) 40%
Critical Property
๐Ÿ”ฅ Flammability
Niet van toepassing
๐Ÿ“Š Upper Explosive Limit
Geen gegevens beschikbaar
๐Ÿ“Š Lower Explosive Limit
Geen gegevens beschikbaar
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Niet van toepassing
๐Ÿ“Š Decomposition Temperature
Geen gegevens beschikbaar
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
log Pow: -1,59
๐Ÿ“Š Solubility In Water
volledig mengbaar
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Geen gegevens beschikbaar
๐Ÿ“Š Kinematic Viscosity
Geen gegevens beschikbaar
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Beschermhandschoenen volgens EN 374. Neem de voorschriften in acht over doorlaatbaarheid en doordrenkingstijd, zoals aangeleverd door de leverancier van de handschoenen. Houd ook rekening met specifieke plaatselijke gebruiksomstandigheden, zoals gevaar voor insnijdingen, slijtage en aanrakingstijd. Veiligheidshandschoenen moeten bij slijtage vervangen worden. Aanbevolen materialen: Natuurrubber (doorbraaktijd >= 8 h, dikte 0,5 mm), Polychloropreen (doorbraaktijd >= 8 h, dikte 0,5 mm), Nitrilrubber (doorbraaktijd >= 8 h, dikte 0,35 mm), Butylrubber (doorbraaktijd >= 8 h, dikte 0,5 mm), Gefluorideerd rubber (doorbraaktijd >= 8 h, dikte 0,4 mm), Polyvinylchloride (doorbraaktijd >= 8 h, dikte 0,5 mm).

๐Ÿ‘๏ธ Eye Protection

Veiligheidsbril met zijschermen volgens EN 166

๐Ÿ˜ท Respiratory Protection

Vereist in geval de blootstellinggrenswaarde wordt overschreden (bijvoorbeeld OEL) of in geval dampen of aerosol vrijkomt. Adembescherming volgens EN 141. Aanbevolen filtertype: Combinatiefilter A-P2.

๐Ÿฆบ Skin/Body Protection

Draag geschikte beschermende arbeidskleding.

๐ŸŒ Environmental Exposure Controls

Niet naar het oppervlaktewater of de riolering laten afvloeien. Vermijd indringen in de bodem.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for UREUM 40%?

The signal word for this substance is "no signal word".

What is the physical form of UREUM 40%?

UREUM 40% is a vloeibaar with kleurloos color. It has zwak, ammoniakaal odor.

What is UREUM 40% used for?

Industrieel gebruik, Beroepsmatig gebruik

What is the melting point of UREUM 40%?

The melting point is circa 0 C 10% oplossing circa -11,5 C 50% oplossing and the boiling point is circa 100 C 10% oplossing 106 - 110 C 50% oplossing.