NextSDS Logo
BI

BICAR TEC

NO SIGNAL WORD kristallijn, poeder SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
BICAR TEC

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Glasindustrie, Detergent, Milieubescherming, Chemische industrie, Rookgasreiniging, Waterbehandeling, Schuimiddelen

Overview

BICAR TEC is a kristallijn, poeder substance commonly used glasindustrie, detergent, milieubescherming, chemische industrie, rookgasreiniging, waterbehandeling, schuimiddelen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

SOLVAY CHEMICALS INTERNATIONAL SA

manufacturer

๐Ÿ“

RUE DU PRINCE ALBERT, 44 B- 1050 BRUXELLES

๐ŸŒ

BE

๐Ÿ“ž

+3225096111

๐Ÿ“ 

+3225096624

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CareChem 24

๐Ÿ“ž

+44(0)208 762 8322

๐ŸŒ

GB

๐Ÿ’ก

Europe

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Natriumbicarbonaat
EC: 205-633-8
144-55-8 98% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

De betreffende persoon uit de omgeving waarin de stof is vrijgekomen verwijderen, hem de neus laten snuiten.

๐Ÿ–๏ธ Skin Contact

Langdurig met veel water afwassen.

๐Ÿ‘๏ธ Eye Contact

Grondig spoelen met veel water, ook onder de oogleden.

Symptoms:

Oogirritatie (indien deze blijft)

๐Ÿฝ๏ธ Ingestion/Swallowing

Bij inslikken van grote hoeveelheid een arts bijroepen. Bij inslikken, mond met water spoelen (alleen als de persoon bij bewustzijn is).

๐Ÿšจ Immediate Medical Attention Required

Bij inslikken van grote hoeveelheid een arts bijroepen. Indien de oogirritatie blijft een specialist raadplegen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
kristallijn, poeder
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
kristallijn, poeder
๐ŸŽจ Colour
wit
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
kristallijn, poeder
๐Ÿ‘ƒ Odor
reukloos
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
8,6
๐ŸงŠ Melting Point
niet van toepassing, Ontleding
Critical Property
๐Ÿ’จ Boiling Point
niet van toepassing, Thermische ontleding
Critical Property
๐Ÿ”ฅ Flash Point
niet van toepassing
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
niet van toepassing
๐Ÿ“Š Vapor Density
niet van toepassing
๐Ÿ“Š Relative Density
2,22
๐Ÿ“Š Bulk Density
tussen 0,5 - 1,2 kg/dm3
โš–๏ธ Density
2,22
Critical Property
๐Ÿ”ฅ Flammability
Het product is niet brandbaar.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Het product is niet brandbaar.
๐Ÿ“Š Decomposition Temperature
- 60 C
๐Ÿ’ง Solubility
Water 96 g/l; Andere: weinig oplosbaar; Alcohol
๐Ÿ“Š Partition Coefficient
niet van toepassing
๐Ÿ“Š Solubility In Water
96 g/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
1,2 mPa.s
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Voor voldoende ventilatie zorgen. Op plaatsen waar stof vrijkomt voor voldoende ventilatie zorgen. Om te voldoen aan de Grenswaarden voor blootstelling dienen technische voorzieningen te worden getroffen.

๐Ÿงค Hand Protection

Draag geschikte handschoenen.

๐Ÿ‘๏ธ Eye Protection

Panoramische en sluitende veiligheidsbril bij stofvorming.

๐Ÿ˜ท Respiratory Protection

Gebruik alleen ademhalingsbescherming conform internationale/nationale normen. Bij stof-, mist-, of rookvorming, stofmasker type P1.

๐ŸŒ Environmental Exposure Controls

Spoelwater afvoeren overeenkomstig de plaatselijke en nationale regel- en wetgeving.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for BICAR TEC?

The signal word for this substance is "no signal word".

What is the physical form of BICAR TEC?

BICAR TEC is a kristallijn, poeder appearing as kristallijn, poeder with wit color. It has reukloos odor.

What is the solubility of BICAR TEC?

Water 96 g/l; Andere: weinig oplosbaar; Alcohol

What is BICAR TEC used for?

Glasindustrie, Detergent, Milieubescherming, Chemische industrie, Rookgasreiniging, Waterbehandeling, Schuimiddelen

What is the melting point of BICAR TEC?

The melting point is niet van toepassing, Ontleding and the boiling point is niet van toepassing, Thermische ontleding.