NextSDS Logo
Safety Data Sheet NL

SOLIPUR MATCOAT A+B Component

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SOLIPUR MATCOAT A+B Component

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

R

RPU

national supplier

Grensstraat 9, B-2270 Herenthout

Emergency Contacts

Emergency Contact

32-(0)14-84.94.10

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Vorm: Viskeuze vloeistof, Kleur: Transparant, Geur: Karakteristiek

Chemical Name CAS Number Concentration Hazardous
Xyleen 001330-20-7 5 - 10% Yes
Isobutylacetaat 000110-19-0 10 - 30% Yes
Hexamethyleen-1-methylethylacetaat 000822-06-0 1% Yes
2-methoxy-1-methylethylacetaat 000108-65-6 30 - 60% Yes
Dimethylbenzylamine 000103-83-3 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In de frisse lucht brengen. Bij ademhalingsmoeilijkheden of niet ademen, kunstmatige ademhaling toepassen en/of arts waarschuwen.

Skin contact

Verontreinigde kleding uittrekken en laten reinigen. Overtollig materiaal met doek verwijderen, reinigen met een geschikt reinigingsmiddel en/of wassen met water en zeep.

Eye contact

Spoelen met veel schoon water gedurende 15 minuten. Ogen open houden. Bij aanhoudende irritatie arts raadplegen.

Ingestion

Mond spoelen en water laten drinken. Geen braken opwekken. Onmiddellijk arts waarschuwen of naar ziekenhuis vervoeren.

Immediate Medical Attention

Onmiddellijk arts waarschuwen of naar ziekenhuis vervoeren.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Kooldioxyde, poeder of alcoholbestendig schuim.

Unsuitable media

Geen water gebruiken.

Specific hazards

Bij brand kunnen cyanide, koolstof- en stikstofoxiden ontstaan.

Firefighter Protection

Persluchtmasker dragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Mag niet geloosd worden in rioleringssystemen en op oppervlaktewateren.

Cleanup methods

opnemen met inert, absorberend materiaal

Materials: inert, absorberend materiaal

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Contact met de huid, ogen en ademhalingswegen vermijden. Verwijderd houden van ontstekingsbronnen.

Storage

Niet relevant voor het gemengde product.

Fire prevention

Verwijderd houden van ontstekingsbronnen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Minimale hoeveelheid te ventileren lucht: 3358 m³/l voor MAC waarden, 63 m³/l voor 10% OEG. Ventilatievormen: Geforceerd ventilatie, beperkte natuurlijke ventilatie, beperkte ventilatie.

Hands

Handschoenen

Eyes

Veiligheidsbril

Respiratory

Verse lucht halfmasker, Halfmasker filter A, Verse lucht volgelaatsmasker, Verse lucht kap

Skin/Body

Beschermende kleding

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
---
Physical State Data
---
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
115-146 °C
Flash Point
31 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
>1
Evaporation Rate
>1
Vapor Pressure
0,49-1,80 kPa
Vapor Density
>1
Relative Density
---
Bulk Density
---
Density
1,05 g/ml
Flammability
---
Upper Explosive Limit
10,8 VOL%
Lower Explosive Limit
1,0 VOL%
Explosive Limits
---
Auto Ignition Temperature
>350 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Veroorzaakt exotherme reacties met aminen en alcoholen.

Incompatible

aminen en alcoholen

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

verbranden in een geschikte en goedgekeurde verbrandingsoven

Disposal

Afval verwerken volgens wettelijke voorschriften van locale-, provinciale-, en centrale overheid

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

EEG gevarencodering: Schadelijk (Xn), ontvlambaar (R10), schadelijk bij inademing, opname door de mond en aanraking met de huid (R20/21/22), kan overgevoeligheid veroorzaken bij inademing en contact met de huid (R42/43), bevat isocyanaten (P53).

Chemical Safety Assessment Not performed

R-zinnen: Ontvlambaar. S-zinnen: Spuitnevel niet inademen. Bij ontoereikende ventilatie een geschikte ademhalingsbescherming dragen. Uitsluitend op goed geventileerde plaatsen gebruiken. S 20/21: niet eten, drinken of roken tijdens gebruik.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SOLIPUR MATCOAT A+B Component?

The signal word is no signal word.