NextSDS Logo
Safety Data Sheet NL

L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur
Product Code
100804

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagens voor analyse, Chemische productie, Farmaceutische productie en analyse

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-2440

Emergency Contacts

Merck KGaA

+49 6151 72112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Irriterend voor de ogen.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
2,3-Dihydroxybernsteinsäure EC: 201-766-0 87-69-4 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht.

Skin contact

Met ruim water afwassen. Verontreinigde kleding verwijderen.

Eye contact

Open oogleden met ruim water uitspoelen. Oogarts waarschuwen.

Ingestion

Slachtoffer veel water laten drinken, laten braken, arts waarschuwen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

poeder, schuim, sproei water.

Specific hazards

Brandbaar. In geval van brand kunnen er gevaarlijke brandgassen en dampen ontstaan.

Firefighter Protection

Niet in de gevaarlijke zone verblijven zonder onafhankelijke ademhalingsapparatuur.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet in riolering laten geraken.

Cleanup methods

Droog opnemen. Ter verwerking aanbieden. Vervuild gebied schoonmaken.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geen nadere eisen.

Storage

Goed afgesloten. Droog. Opslagtemperatuur: zonder beperking

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Bij vol contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 480 Min. Bij sproei contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 480 Min. De te gebruiken beschermende handschoenen, moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 740 Dermatril®.

Eyes

Bescherming van de ogen: benodigd

Respiratory

Bescherming van de ademhalingswegen: nodig indien stofvorming plaatsvindt.

Skin/Body

Het soort lichaamsbescherming moet al naargelang van de concentratie en de hoeveelheid gevaarlijke stoffen op de werkplek gekozen worden. De chemische weerstand van de bescherming moet met de leverancier geregeld worden.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
---
Density
1.76 g/cm³ (20 °C)
Cloud Point
---
Molecular Weight
---
Solubility In Fat
---
Solidification Point
---
Solubility
ethanol (20 C) oplosbaar
Appearance
---
Explosive Limits
---
State Under Standard Conditions
---
Odor
geurloos
Physical State
vast
Dynamic Viscosity
---
Properties Status
---
Crystallisation Point
---
Softening Point
---
Bulk Density
~ 800-1000 kg/m³
Upper Explosive Limit
niet beschikbaar
Auto Ignition Temperature
425 °C
Colour Intensity
---
Vapor Density
---
Voc Content
---
Freezing Point
---
Form
---
Decomposition Temperature
> 170 °C
Vapor Pressure
laag
Partition Coefficient
-0.76 (berekend)
Metal Corrosion
---
Melting Point
168-170 °C
Colour
wit
Boiling Point
niet van toepassing
Evaporation Rate
---
Odor Threshold
---
Kinematic Viscosity
---
Flash Point
210 °C
Relative Evaporation Rate
---
Physical State Data
solid
Ph
~ 1.6 (25 °C)
Solubility In Water
1390 g/l (20 °C), 3430 g/l (100 °C)
Relative Density
---
Lower Explosive Limit
niet beschikbaar
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

geen informatie beschikbaar

Incompatible

fluor, zilver, metalen.

Decomposition

geen informatie beschikbaar

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Chemicaliën moeten met inachtneming van de desbetreffende nationale voorschriften afgevoerd worden. Onder www.retrologistik.de vindt u zowel de landen- en stofspecifieke informatie als de contact partners.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Etikettering volgens EG richtlijnen. R-zinnen: 36 (Irriterend voor de ogen). S-zinnen: 24/25 (Aanraking met de ogen en de huid vermijden).

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

The signal word is no signal word.

What is the physical form of L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur is a vast with wit color. It has geurloos odor.

What is the solubility of L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

ethanol (20 C) oplosbaar

What is L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur used for?

Reagens voor analyse, Chemische productie, Farmaceutische productie en analyse

What are the hazard statements for L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

This substance has 1 hazard statement:

  • Irriterend voor de ogen.

What is the melting point of L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

The melting point is 168-170 °C and the boiling point is niet van toepassing.