NextSDS Logo
L(

L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur

NO SIGNAL WORD vast SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur
Product Code
100804

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagens voor analyse, Chemische productie, Farmaceutische productie en analyse

Overview

L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur commonly used reagens voor analyse, chemische productie, farmaceutische productie en analyse.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Eye Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • Irriterend voor de ogen.

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA

undefined

64271 Darmstadt, Germany

DE

+49 6151 72-2440

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Merck KGaA

+49 6151 72112

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2,3-Dihydroxybernsteinsure
EC: 201-766-0
87-69-4 Not specified Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

frisse lucht.

Skin Contact

met ruim water afwassen. Verontreinigde kleding verwijderen.

Eye Contact

open oogleden met ruim water uitspoelen.

Ingestion/Swallowing

slachtoffer veel water laten drinken, laten braken.

Immediate Medical Attention Required

Oogarts waarschuwen. Arts waarschuwen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Upper Explosive Limit
niet beschikbaar
Evaporation Rate
Not available
Auto Ignition Temperature
425 C
Solubility In Water
(20 C) 1390 g/l, (100 C) 3430 g/l
Partition Coefficient
-0.76
Density
(20 C) 1.76 g/cm
Critical Property
Appearance
Not available
Relative Evaporation Rate
Not available
Solubility In Fat
Not available
Melting Point
168-170 C
Critical Property
Vapor Pressure
laag
Flash Point
210 C
Critical Property
Voc Content
Not available
Vapor Density
Not available
State Under Standard Conditions
Not available
Decomposition Temperature
> 170 C
Odor
geurloos
Odor Threshold
Not available
Kinematic Viscosity
Not available
Solidification Point
Not available
Flammability
Not available
Crystallisation Point
Not available
Lower Explosive Limit
niet beschikbaar
Colour Intensity
Not available
Explosive Limits
Not available
Bulk Density
~ 800-1000 kg/m
Molecular Weight
Not available
Solubility
ethanol (20 C) oplosbaar
Physical State Data
solid
Physical State
vast
Critical Property
Ph
bij 100 g/l HO (25 C) ~ 1.6
Cloud Point
Not available
Softening Point
Not available
Metal Corrosion
Not available
Colour
wit
Freezing Point
Not available
Relative Density
Not available
Form
Not available
Properties Status
Not available
Boiling Point
niet van toepassing
Critical Property
Dynamic Viscosity
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Bij vol contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 480 Min. Bij sproei contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 480 Min. De te gebruiken beschermende handschoenen moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 740 Dermatril (volledig contact), 740 Dermatril (spat contact).

Eye Protection

Benodigd

Respiratory Protection

Nodig indien stofvorming plaatsvindt.

Skin/Body Protection

Het soort lichaamsbescherming moet al naargelang van de concentratie en de hoeveelheid gevaarlijke stoffen op de werkplek gekozen worden. De chemische weerstand van de bescherming moet met de leverancier geregeld worden.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

The signal word for this substance is "no signal word".

What is the physical form of L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur is a vast with wit color. It has geurloos odor.

What is the solubility of L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

ethanol (20 C) oplosbaar

What is L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur used for?

Reagens voor analyse, Chemische productie, Farmaceutische productie en analyse

What are the hazard statements for L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

This substance has 1 hazard statements: Irriterend voor de ogen.

What is the melting point of L(+)-Wijnsteenzuur pro analyse ACS,ISO,Reag. Ph Eur?

The melting point is 168-170 C and the boiling point is niet van toepassing.