NextSDS Logo
Safety Data Sheet NL

SIGMETAL NEOFER DECOR

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SIGMETAL NEOFER DECOR
Product Code
10100DN3172

Regulatory Identifiers

CAS Number
N/A

Identified Uses

verf

Manufacturers & Suppliers

P

PPG Coatings Deco Belux N.V./S.A.

manufacturer

Genkersteenweg 311 B-3500 Hasselt

+32 (0)11 278 701

Emergency Contacts

Emergency Contact

+32 (0)70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

De producent verklaart dat voor de in hoofdstuk 3 niet vermelde R-zinnen, de totale hoeveelheid gevaarlijke componenten beneden de grens liggen.Het benzeengehalte van dit product is minder dan 0,1%. Nota P en H zijn van toepassing.

Chemical Name CAS Number Concentration Hazardous
Solvent naphtha (petroleum), heavy aromatic EC: 265-198-5 64742-94-5 10 - 20% Yes
ETHYL METHYL KETOXIME EC: 202-496-6 96-29-7 0.1 - 1% Yes
Naphta lourd (ptrole), hydrotrait EC: 265-150-3 64742-48-9 10 - 20% Yes
Naphta lourd (ptrole), hydrotrait EC: 265-150-3 64742-48-9 10 - 20% Yes
Vetzuren, C6-19 vertakt, Kobalt zout EC: 270-066-5 68409-81-4 0.1 - 1% Yes

- Kandidaat-lijst van zeer zorgwekkende stoffen voor autorisatie

Notes

Indien meerdere ingredienten met gelijke namen of nummers verschijnen hebben deze verschillende gevaren eigenschappen, bijvoorbeeld vlampunt.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medische advies inwinnen.

Skin contact

Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger.

Eye contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen. Medisch advies inwinnen.

Ingestion

Bij inslikken direkt arts raadplegen. Het slachtoffer laten rusten.

Immediate Medical Attention

Als de ziekteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingeroepen. Bij bewusteloosheid (na inademing) medisch advies inwinnen. Na oogcontact medisch advies inwinnen. Bij inslikken direct arts raadplegen. Bij verbranding medische hulp inroepen. Bij een ongeval of indien men zich onwel voelt onmiddellijk een arts raadplegen (indien mogelijk het etiket tonen). Dit veiligheidsinformatieblad aan de dienstdoende arts tonen.

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If workers, even if not directly involved in product processing, are in a spray booth, ventilation must be present for spray particles and solvent vapors.

Hands

Use gloves for prolonged or repeated contact. Protective creams can help protect exposed skin. Wash thoroughly after skin contact. Use chemical-resistant gloves as indicated in standard EN 374: Protective gloves against chemicals and microorganisms. Recommended gloves: Nitrile rubber. Minimum breakthrough time: 480 min. For prolonged and regular contact, a glove with protection class 6 (breakthrough time > 480 minutes according to EN 374) is recommended. For short contact, a glove with protection class 2 or higher (breakthrough time > 30 minutes according to EN 374) is recommended. NOTE: The choice of a specific glove for certain applications and duration of use should also be based on all relevant workplace factors such as, but not limited to: other chemicals used, physical requirements (cut/puncture protection, ease of use, thermal protection), possible bodily reactions to the glove material, and instructions/specifications provided by the glove supplier.

Eyes

Wearing chemical-resistant safety glasses is mandatory.

Respiratory

If workers, even if not directly involved in product processing, are in a spray booth, ventilation must be present for spray particles and solvent vapors. Under these circumstances, they must wear a fresh-air hood during the spraying process until the concentration has dropped below the MAC value.

Skin/Body

Personnel must wear protective clothing. Wash thoroughly after skin contact. Workwear should not consist of textiles that exhibit dangerous melting behavior in case of fire. Wearing anti-static footwear is mandatory.

Environmental

Refer to national legislation in chapter 15 for environmental protection regulations.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
---
Physical State Data
---
State Under Standard Conditions
---
Appearance
---
Colour
verscheidene
Colour Intensity
---
Form
viskeus
Odor
licht koolwaterstofachtig
Odor Threshold
---
Ph
niet van toepassing
Melting Point
---
Boiling Point
---
Flash Point
47.0 C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.23 g/cm3 bij 20 C
Flammability
---
Upper Explosive Limit
6.51 %(V) 401.8 g/m3
Lower Explosive Limit
0.61 %(V) 38.21 g/m3
Explosive Limits
---
Auto Ignition Temperature
Opmerking: geen gegevens beschikbaar
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
bijna onoplosbaar
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
3,000 mPa.s bij 23 C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
PAINT
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SIGMETAL NEOFER DECOR?

The signal word is na: r-phrases.

What is SIGMETAL NEOFER DECOR used for?

verf

Compliance Scanner

Scan your compliance