NextSDS Logo
SI

SIGMA TIGRON AQUA PRIMER

NO SIGNAL WORD SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMA TIGRON AQUA PRIMER

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Verf

Overview

SIGMA TIGRON AQUA PRIMER commonly used verf.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

PPG Coatings Deco Belux N.V./S.A.

manufacturer

Genkersteenweg 311 B-3500 Hasselt

BE

+32 (0)11 278 701

+32 (0)11 278 700

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 (0)70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Het benzeengehalte van dit product is minder dan 0,1%. Nota P en H zijn van toepassing.

Additional Information

Indien meerdere ingredienten met gelijke namen of nummers verschijnen hebben deze verschillende gevaren eigenschappen, bijvoorbeeld vlampunt.

Composition Notes

De producent verklaart dat voor de in hoofdstuk 3 niet vermelde R-zinnen, de totale hoeveelheid gevaarlijke componenten beneden de grens liggen. Geen gevaarlijke bestanddelen volgens EG richtlijn 67/548/EC.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen.

Skin Contact

Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger.

Eye Contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen.

Ingestion/Swallowing

Het slachtoffer laten rusten.

Immediate Medical Attention Required

Als de ziekteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingeroepen. Medisch advies inwinnen (bij oogcontact en bewusteloosheid na inademing). Bij inslikken direkt arts raadplegen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Not available
Physical State Data
Not available
State Under Standard Conditions
Not available
Appearance
Not available
Colour
verscheidene
Colour Intensity
Not available
Form
viskeus
Odor
licht amine-achtig
Odor Threshold
Not available
Ph
8.0 - 8.5
Melting Point
Not available
Boiling Point
Not available
Flash Point
niet van toepassing
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
Not available
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
1.26 g/cm3 bij 20 C
Critical Property
Flammability
Not available
Upper Explosive Limit
niet van toepassing
Lower Explosive Limit
niet van toepassing
Explosive Limits
Not available
Auto Ignition Temperature
niet van toepassing
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
dispergeerbaar
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
2,000 - 2,500 mPa.s bij 23 C
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Indien werknemers - ook als ze niet zelf bezig zijn met de verwerking van het product - zich in een spuitcabine bevinden, dient ventilatie aanwezig te zijn voor eventuele spuitdeeltjes en oplosmiddeldampen.

Hand Protection

Bij langer of herhaaldelijk kontakt handschoenen gebruiken. Gerbuik chemicalienbestendige handschoenen, zoals aangegeven in standaard EN 374: Beschermende handschoenen tegen chemicalien en microorganismen. Aanbevolen handschoenen: Nitrilrubber. Indien langdurig en regelmatig contact voorkomt, is een handschoen met een beschermingsklasse 6 (doorbreektijd meer dan 480 minuten volgens EN 374) aanbevolen. Als slechts een kort contact verwacht wordt, is een handschoen met een beschermingsklasse 2 of hoger (doorbreektijd groter dan 30 minuten volgens EN 374) aanbevolen. ATTENTIE: De keuze van een specifieke handschoen voor bepaalde applicaties en de duur van gebruik zou mede gebaseerd moeten zijn op alle relevante factoren op de werkplaats zoals, maar niet gelimiteerd tot: andere chemicalien die gebruikt worden, fysieke vereisten (snij/doorboor bescherming, gebruiksgemak, thermische bescherming), mogelijke lichaamsreacties op het materiaal van de handschoenen, maar ook de instructies/specificaties geleverd door de handschoenleverancier.

Eye Protection

Het dragen van een chemicalienbestendige beschermingsbril is verplicht.

Respiratory Protection

Indien werknemers - ook als ze niet zelf bezig zijn met de verwerking van het product - zich in een spuitcabine bevinden, dient ventilatie aanwezig te zijn voor eventuele spuitdeeltjes en oplosmiddeldampen. In deze omstandigheden dienen zij een verse-lucht kap te dragen tijdens het spuitproces tot het moment dat de concentratie is gedaald tot beneden de MAC-waarde.

Skin/Body Protection

Het personeel dient beschermende kleding te dragen. Na kontakt met de huid grondig wassen.

Environmental Exposure Controls

Zie de nationale wetgeving in hoofdstuk 15 voor wetgeving met betrekking op mileubescherming.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMA TIGRON AQUA PRIMER?

The signal word for this substance is "no signal word".

What is SIGMA TIGRON AQUA PRIMER used for?

Verf