NextSDS Logo
Safety Data Sheet NL

SIGMA VERDUNNING 90-53

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SIGMA VERDUNNING 90-53
Product Form
Vloeistof

Regulatory Identifiers

CAS Number
N/A
02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Xyleen 001330-20-7 60 - 100% Yes
1-Methoxy-2-propanol 000107-98-2 30 - 60% Yes
Propyleen-1-glycol-2-methylether 001589-47-5 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Onmiddellijk in de frisse lucht brengen. Patient warm en rustig houden. Bij ademhalingsmoeilijkheden of niet ademen, kunstmatige ademhaling toepassen en/of onmiddellijk arts waarschuwen. Bij bewusteloosheid de patiënt in stabiele zijligging leggen.

Skin contact

Verontreinigde kleding uittrekken. Wassen met water en zeep.

Eye contact

Spoelen met veel schoon water gedurende 15 minuten. Ogen open houden. Bij aanhoudende irritatie arts raadplegen.

Ingestion

Mond spoelen en water laten drinken. Geen braken opwekken. Onmiddellijk arts waarschuwen of naar ziekenhuis vervoeren.

Immediate Medical Attention

Onmiddellijk arts waarschuwen of naar ziekenhuis vervoeren.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Waterstraal, kooldioxyde, poeder of alcoholbestendig schuim.

Specific hazards

Bij brand kunnen koolstofoxiden ontstaan.

Firefighter Protection

In besloten ruimten persluchtmasker dragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Verwijderen van alle personen die geen geschikte beschermingsmiddelen dragen

Environmental

Mag niet geloosd worden in rioleringssystemen en op oppervlaktewateren.

Cleanup methods

opnemen met inert, absorberend materiaal

Materials: inert, absorberend materiaal

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Contact met de huid, ogen en ademhalingswegen vermijden. Verwijderd houden van ontstekingsbronnen.

Storage

Goed gesloten verpakkingen bewaren in een koele en goed geventileerde ruimte. Verwijderd houden van ontstekingsbronnen.

Fire prevention

Verwijderd houden van ontstekingsbronnen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Minimale hoeveelheid te ventileren lucht die nodig is voor 1 liter produkt: om MAC te bereiken: 2197 m3/l, om 10% OEG te bereiken: 159 m3/l. Advies per werkomgeving: Verfverwerkingsruimten: geforceerde ventilatie; Buitenlucht: beperkte natuurlijke ventilatie; Besloten ruimten: beperkte ventilatie.

Hands

Handschoenen

Eyes

Veiligheidsbril

Respiratory

Halfmasker filter A voor verfverwerkingsruimten; Verse lucht halfmasker voor buitenlucht en besloten ruimten.

Skin/Body

Beschermende kleding

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
---
Physical State Data
---
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
120 - 143 °C
Flash Point
30 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
> 1
Evaporation Rate
> 1
Vapor Pressure
0,67 - 1,30 kPa
Vapor Density
> 1
Relative Density
---
Bulk Density
---
Density
0,88 g/ml
Flammability
---
Upper Explosive Limit
11,5 vol. %
Lower Explosive Limit
1,0 vol. %
Explosive Limits
---
Auto Ignition Temperature
> 270 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Fractioneel
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Incompatible

Veroorzaakt exotherme reacties in contact met oxidatiemiddelen en sterke zuren.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

verbranden in een geschikte en goedgekeurde verbrandingsoven

Disposal

Afval verwerken volgens wettelijke voorschriften van locale-, provinciale-, en centrale overheid

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

15.1 EEG, 15.2 BESLUIT OPSLAG GOEDEREN HINDERWET, 15.3 BESLUIT AANWIJZING CHEMISCHE AFVALSTOFFEN

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SIGMA VERDUNNING 90-53?

The signal word is no signal word.