NextSDS Logo
Du

DuPont ISCEON MO59 (R-417A) Refrigerant

WARNING Vloeibaar gemaakt gas SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DuPont ISCEON MO59 (R-417A) Refrigerant
Product Code
R-417A

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Koelmiddel, Uitsluitend bestemd voor professionele gebruikers.

Overview

DuPont ISCEON MO59 (R-417A) Refrigerant commonly used koelmiddel, uitsluitend bestemd voor professionele gebruikers..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Waarschuwing)

Hazard Classifications

Gassen onder druk H280

GHS Hazard Pictograms & Safety Symbols

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H280: Bevat gas onder druk; kan ontploffen bij verwarming.

Precautionary Statements

  • P410+P403: Tegen zonlicht beschermen. Op een goed geventileerde plaats bewaren.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Du Pont de Nemours (Nederland) B.V.

manufacturer

πŸ“

Baanhoekweg 22 NL-3313 LA Dordrecht Nederland

🌍

NL

πŸ“ž

+31-(0)-78-630-1011

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+(32)-28083237

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

De hierboven vermelde producten voldoen aan de REACH-registratieverplichtingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Tetrafluoroethaan
EC: 212-377-0
811-97-2 50% ⚠️ Hazardous
Pentafluorethaan
EC: 206-557-8
354-33-6 46.6% ⚠️ Hazardous
Butaan (<0.1% butadieen)
EC: 203-448-7
106-97-8 3.4% ⚠️ Hazardous

Composition Notes

het is mogelijk dat registratienummers niet worden vermeld omdat de stoffen zijn vrijgesteld, nog niet onder REACH zijn geregistreerd of zijn geregistreerd onder een ander regulerend proces (gebruik van biocides, gewasbeschermingsmiddelen), enz. Voor de volledige tekst van de R-zinnen die worden genoemd in deze paragraaf, zie Paragraaf 16. Voor de volledige text van H-zinnen zoals vermeld in deze paragraaf, zie paragraaf 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Verwijderen van blootstelling, neerleggen. In de frisse lucht brengen. Slachtoffer warm en rustig houden. Kunstmatige beademing en/of zuurstof kan noodzakelijk zijn. Een arts raadplegen.

Symptoms:

Misbruik of opzettelijke inademing kan zonder waarschuwingsverschijnselen fataal worden tengevolge van harteffecten. Andere verschijnselen die mogelijk kunnen wijzen met misbruik of overtreding van het inademingverbod zijn: Verdovende effecten, Licht in het hoofd, duizeligheid, verwardheid, gebrek aan coΓΆrdinatie, slaperigheid of bewusteloosheid, onregelmatige hartslag met een vreemd gevoel op de borst, hartkloppingen, gevoel van ongerustheid, gevoel van flauwte, duizeligheid of zwakte, Slaperigheid, narcose.

πŸ–οΈ Skin Contact

Verontreinigde kleding en schoenen onmiddellijk uittrekken. De getroffen plek spoelen met handwarm water. Geen heet water gebruiken. In geval van bevriezingsverschijnselen een arts waarschuwen.

Symptoms:

Bevriezing, Irritatie, Ongemak, Jeuk, Roodheid, Opzwellen van het weefsel.

πŸ‘οΈ Eye Contact

Oogleden open houden en de ogen spoelen met veel water gedurende tenminste 15 minuten. Medische hulp inroepen.

Symptoms:

Bevriezing, Irritatie, Tranen, roodheid of ongemak.

🚨 Immediate Medical Attention Required

Medische hulp inroepen bij bewusteloosheid, onregelmatige ademhaling of ademstilstand. Een arts raadplegen indien symptomen aanhouden, na inademing, bij oogcontact, en in geval van bevriezingsverschijnselen na huidcontact.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Bulk Density
Not available
πŸ’¨ Boiling Point
- 39,1
Critical Property
πŸ“Š Voc Content
Not available
πŸ“Š Crystallisation Point
Not available
🎨 Colour
kleurloos
πŸ“Š Explosive Limits
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Solubility In Water
Not available
πŸ“Š Partition Coefficient
Not available
πŸ“Š Form
Vloeibaar gemaakt gas
πŸ“Š Properties Status
Not available
πŸ‘ƒ Odor
licht, etherachtig
πŸ“Š Dynamic Viscosity
Not available
πŸ’¨ Evaporation Rate
Not available
πŸ‘οΈ Appearance
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Upper Explosive Limit
Type: bovenste ontvlambaarheidsgrenswaarde, Methode: ASTM E681, Geen.
πŸ“Š Solubility In Fat
Not available
πŸ“Š Colour Intensity
Not available
πŸ’§ Solubility
Not available
πŸ“Š Molecular Weight
Not available
πŸ§ͺ Ph
neutraal
πŸ“Š Vapor Density
Not available
πŸ“Š Lower Explosive Limit
Type: onderste ontvlambaarheidsgrenswaarde, Methode: ASTM E681, Geen.
πŸ“Š Freezing Point
Not available
βš–οΈ Density
1,2 g cm3 bij 20 , (als vloeistof); 0,0044 g cm3 bij 25 (1 013 hPa)
Critical Property
πŸ”₯ Flammability
Niet van toepassing
πŸ“Š Solidification Point
Not available
πŸ§ͺ Physical State
Vloeibaar gemaakt gas
Critical Property
πŸ“Š Odor Threshold
Not available
πŸ“Š Relative Density
1,15 bij 25
πŸ“Š State Under Standard Conditions
Not available
🧊 Melting Point
Niet beschikbaar voor dit mengsel
Critical Property
πŸ“Š Auto Ignition Temperature
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Physical State Data
gas
πŸ’¨ Vapor Pressure
9 835 hPa bij 25
πŸ”₯ Flash Point
Niet van toepassing
Critical Property
πŸ“Š Decomposition Temperature
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Voor geschikte ventilatie zorgen, vooral in gesloten ruimten. Als grote hoeveelheden vrijkomen moet plaatselijke afzuiging worden gebruikt.

🧀 Hand Protection

Materiaal: Lederen handschoenen

πŸ‘οΈ Eye Protection

Draag een veiligheidsbril of chemicalienpak met spatwaterdichte beschermbril. Oogbescherming volgens EN166. of ANSI Z87.1 Tevens een gelaatscherm dragen als er een mogelijkheid lijkt te zijn dat er aanraking met het gelaat kan plaatsvinden als gevolg van spatten, spuiten of middels luchtgedragen overdracht.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1078

πŸ“¦ Proper Shipping Name

KOELGAS, N.E.G. (1,1,1,2-Tetrafluoroethane, Pentafluoroethane)

⚠️ Transport Hazard Class

2

πŸ“‹ Packing Group

Niet van toepassing

πŸš› ADR Transport Precautions

geen gegevens beschikbaar

🚒 IMDG Maritime Transport Precautions

geen gegevens beschikbaar

✈️ IATA Air Transport Precautions

geen gegevens beschikbaar

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DuPont ISCEON MO59 (R-417A) Refrigerant?

The signal word for this substance is "warning".

What is the physical form of DuPont ISCEON MO59 (R-417A) Refrigerant?

DuPont ISCEON MO59 (R-417A) Refrigerant is a vloeibaar gemaakt gas with kleurloos color. It has licht, etherachtig odor.

What is DuPont ISCEON MO59 (R-417A) Refrigerant used for?

Koelmiddel, Uitsluitend bestemd voor professionele gebruikers.

What are the hazard statements for DuPont ISCEON MO59 (R-417A) Refrigerant?

This substance has 1 hazard statements: H280: Bevat gas onder druk; kan ontploffen bij verwarming.

What is the melting point of DuPont ISCEON MO59 (R-417A) Refrigerant?

The melting point is Niet beschikbaar voor dit mengsel and the boiling point is - 39,1.