Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tangit KS Reiniger
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
reiniger
Manufacturers & Suppliers
Henkel Nederland B.V.
national supplier
Brugwal 11, 3432 NZ Nieuwegein, Nederland
+31 (30) 60 73 911
https://mysds.henkel.com/index.html#/appSelection
Emergency Contacts
Emergency Contact
+32 70 222 076
24 h
NVIC Nederland, Nationaal Vergiftigingen Informatie Centrum
088 755 8000
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Vermelding van ingredinten conform CLP (EC) nr 1272/2008
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethanol EC: 200-578-6 | 64-17-5 | 80 - 100% | Yes |
Notes
Als er geen ATE-waarden worden weergegeven, raadpleeg dan de LD/LC50-waarden in Rubriek 11. Volledige text van de H-verklaring en andere afkortingen zie hoofdstuk 16 "Overige informatie".
First Aid Measures
Emergency procedures for chemical exposure incidents
Frisse lucht, bij aanhoudende klachten arts consulteren.
spoelen onder stromend water met zeep. huidverzorging: verontreinigde kleding verwisselen
Onmiddellijk de ogen spoelen met een zachte waterstraal of een oogspoelmiddel voor minstens 5 minuten. Indien de pijn aanhoudt (intensieve pijn, gevoelig voor licht, visuele storing), blijven spoelen en een dokter consulteren of naar het hospitaal gaan.
Symptoms: pijn, intensieve pijn, gevoelig voor licht, visuele storing
Mondholte spoelen, geen braken opwekken, arts consulteren.
Immediate Medical Attention
Bij klachten arts consulteren. Indien de pijn aan de ogen aanhoudt (intensieve pijn, gevoelig voor licht, visuele storing), een dokter consulteren of naar het hospitaal gaan.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation.
In case of prolonged contact, protective rubber nitrile gloves are recommended according to EN 374. Breakthrough time > 120 min, material thickness > 0.6 mm. For longer and repeated contact, it should be noted that the aforementioned penetration time in practice can be considerably shorter than described in EN 374. The protective gloves must in any case be resistant to the work-specific use (mechanical and thermal durability, product-adapted, antistatic, etc.). At the first signs of wear, they should be replaced immediately. The manufacturer's instructions and safety guidelines must always be followed. We recommend drawing up an application-specific hand protection plan in cooperation with the glove supplier and the professional federation.
Fully enclosed safety glasses. Eye protection must comply with EN 166.
If ventilation is insufficient, wear a suitable mask. The filter of the combination: ABEKP (EN 14387). This recommendation should be checked with local conditions.
Suitable safety clothing. Protective clothing must comply with EN 14605 for liquid splashes and with EN 13982 for dust.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1170
- Shipping Name
- ETHANOL, OPLOSSING
- Transport Class
- 3
- Packing Group
- II
Tunnelcode: (D/E)
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tangit KS Reiniger?
The signal word is danger.
What is the physical form of Tangit KS Reiniger?
Tangit KS Reiniger is a vloeistof appearing as kleurloos, zuiver with kleurloos color. It has intensief, alcoholachtig odor.
What is the solubility of Tangit KS Reiniger?
oplosbaar
What is Tangit KS Reiniger used for?
reiniger
What are the hazard statements for Tangit KS Reiniger?
This substance has 2 hazard statements:
- H225: Licht ontvlambare vloeistof en damp.
- H319: Veroorzaakt ernstige oogirritatie.
What is the melting point of Tangit KS Reiniger?
The melting point is Niet van toepassing, Product is een vloeistof and the boiling point is 79 C (174.2 F)geen methode / methode onbekend (1.013 hPa).