NextSDS Logo
Safety Data Sheet NL

ANTIFROGEN L

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ANTIFROGEN L
Product Code
107600
Chemical Name
1,2-propandiol en inhibitoren

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industriele sector : Functionele vloeistoffen. Gebruikstype : Zoutwater voor afkoeling

Manufacturers & Suppliers

C

Clariant Produkte (Deutschland) GmbH

manufacturer

65926 Frankfurt am Main

+49 69 305 18000

Emergency Contacts

Emergency Contact

00800-5121 5121

24 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
methyl-1H-benzotriazole EC: 249-596-6 29385-43-1 0.1 - 0.25% Yes

Notes

For explanation of abbreviations, see section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bij inademing overbrengen in de frisse lucht. Een arts raadplegen.

Skin contact

Bij aanraking met de huid onmiddellijk grondig spoelen met veel water.

Eye contact

Bij aanraking met de ogen onmiddellijk met veel water spoelen en medisch advies inwinnen.

Ingestion

Onmiddellijk medische hulp inroepen.

Immediate Medical Attention

Onmiddellijk medische hulp inroepen (bij inslikken). Een arts raadplegen (bij inademing). Medisch advies inwinnen (bij aanraking met de ogen).

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Uitsluitend op goed geventileerde plaatsen gebruiken.

Hands

For long-term exposure: Impermeable butyl rubber gloves with a breakthrough time of 480 min and a thickness of 0.7 mm. For short-term exposure (splash protection): Nitrile rubber gloves with a breakthrough time of 30 min and a thickness of 0.4 mm. Always consider data from the glove producer, especially regarding minimum thickness, breakthrough time, and special working conditions.

Eyes

beschermbril

Respiratory

Bij dampvorming een respirator gebruiken met een goedgekeurd filtertype. De uitrusting moet in overeenstemming zijn met EN 14387. Als niet voldaan kan worden aan de MAC-waarden, kan in uitzonderlijke gevallen en slechts gedurende korte perioden geschikte ademhalingsapparatuur gedragen worden. Filter type: Type organische damp (A).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flash Point
ca. 105 C
Voc Content
---
Softening Point
---
Kinematic Viscosity
ca. 59 mm2/s (20 C)
Form
---
Auto Ignition Temperature
- 450 C
Evaporation Rate
Niet uitgevoerd
Upper Explosive Limit
12,6 %(V)
Physical State
Vloeistof
Lower Explosive Limit
2,6 %(V)
Vapor Pressure
< 0,01 kPa (20 C)
Dynamic Viscosity
ca. 62 mPa.s
Decomposition Temperature
> 250 C
Melting Point
ca. -58 C
Appearance
---
Density
ca. 1,043 g/cm3 (20 C)
Explosive Limits
---
Physical State Data
liquid
Solidification Point
---
Colour Intensity
---
Odor
waarneembaar
Vapor Density
---
Solubility
(20 C) mengbaar
Bulk Density
---
Ph
ca. 9 (20 C)
Properties Status
---
Boiling Point
ca. 155 C (1.013 hPa)
State Under Standard Conditions
---
Solubility In Water
(20 C) mengbaar
Relative Density
---
Metal Corrosion
< 6,25 mm/a
Freezing Point
---
Solubility In Fat
---
Partition Coefficient
Niet van toepassing
Odor Threshold
Niet uitgevoerd
Relative Evaporation Rate
---
Cloud Point
---
Molecular Weight
---
Flammability
---
Colour
blauw
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ANTIFROGEN L?

The signal word is no signal word.

What is the physical form of ANTIFROGEN L?

ANTIFROGEN L is a vloeistof with blauw color. It has waarneembaar odor.

What is the solubility of ANTIFROGEN L?

(20 C) mengbaar

What is ANTIFROGEN L used for?

Industriele sector : Functionele vloeistoffen. Gebruikstype : Zoutwater voor afkoeling

What is the melting point of ANTIFROGEN L?

The melting point is ca. -58 C and the boiling point is ca. 155 C (1.013 hPa).