NO SIGNAL WORD Vast. Diepgekoeld vast gas. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Droogijs blok 300 x 147 x 155mm
Chemical Name
CARBON DIOXIDE AEROSOL PROPELLANT substance with national workplace exposure limit(s) (GB); substance with a Community workplace exposure limit
Synonyms
Gasart 370 BIOGON C, E290, Gasart 374 Kohlendioxid, Gasart 375 Kohlendioxid med., Gasart 471 Kltemittel R 744, Gasart 471 Kohlendioxid 4.5, Gasart 472 Kohlendioxid 4.8, Gasart 473 Kohlendioxid 2.0, Kohlendioxid 3.0, Kohlendioxid 5.3, R744

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Voedingsindustrie
Uses Advised Against
In drank voor het mist effect, vanwege het risico van inslikken.

Overview

Droogijs blok 300 x 147 x 155mm (CAS: 124-38-9 ) is a diepgekoeld vast gas. substance commonly used voedingsindustrie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Niet van toepassing.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Air Products N.V.

manufacturer

Leonardo Da Vincilaan 19C - Bus 4 1831 Diegem Belgi

BE

+32 (0)78 15 52 02

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

32-28083237

BE

Cilinder, Bulk, Medisch

Anti Gif Centrum

07 0245245 / +32 70245245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Concentratie is nominaal. Raadpleeg de technische specificaties voor de exacte samenstelling van het product.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
CARBON DIOXIDE AEROSOL PROPELLANT substance with national workplace exposure limit(s) (GB); substance with a Community workplace exposure limit
EC: 204-696-9
124-38-9 100% Non-hazardous

Composition Notes

Concentratie is nominaal. Raadpleeg de technische specificaties voor de exacte samenstelling van het product.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

In de frisse lucht brengen.

Symptoms:

Ademnood. Versnelde ademhaling.

Skin Contact

In geval van bevriezing met water sproeien gedurende minstens 15 minuten. Breng een steriel verband aan. Behandel als brandwonden. Medisch advies inwinnen.

Symptoms:

Bevriezing.

Eye Contact

Bij aanraking met de ogen onmiddellijk met veel water spoelen en deskundig medisch advies inwinnen.

Symptoms:

Troebel zicht.

Ingestion/Swallowing

Onmiddellijk een arts waarschuwen. Voorkom inademing van braaksel. Draai het hoofd van het slachtoffer opzij.

Medical Treatment

Pas geassisteerde ademhaling toe als de ademhaling tot stilstand is gekomen of bij zware ademhaling. Ook moet mogelijk extra zuurstof worden toegediend. Als het hart tot stilstand is gekomen, moet getraind personeel onmiddellijk overgaan tot cardiopulmonaire resuscitatie.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Vast. Diepgekoeld vast gas.
Critical Property
Physical State Data
solid
State Under Standard Conditions
Not available
Appearance
Diepgekoeld vast gas.
Colour
Wit.
Colour Intensity
Not available
Form
Not available
Odor
Geen geur waarschuwingskenmerken.
Odor Threshold
Geurwaarnemingsdrempel is subjectief en niet geschikt als waarschuwing voor overmatige blootstelling.
Ph
Niet van toepassing voor gassen en gasmengsels.
Melting Point
-70 F (-56.6 C)
Critical Property
Boiling Point
Geen gegevens beschikbaar.
Critical Property
Flash Point
Niet van toepassing voor gassen en gasmengsels.
Critical Property
Freezing Point
-70 F (-56.6 C)
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Niet van toepassing voor gassen en gasmengsels.
Vapor Pressure
831.04 psia (57.30 bara) bij 68 F (20 C)
Vapor Density
0.0018 g/cm3 (0.112 lb/ft3) bij 21 C ( 70 F)
Relative Density
1.5 (water = 1)
Bulk Density
Not available
Density
0.0018 g/cm3 (0.112 lb/ft3) bij 21 C ( 70 F)
Critical Property
Flammability
Raadpleeg de classificatie van het product in sectie 2
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
Not available
Auto Ignition Temperature
Niet brandbaar.
Decomposition Temperature
Niet van toepassing.
Solubility
Not available
Partition Coefficient
0.83
Solubility In Water
2.000 g/l
Solubility In Fat
Not available
Molecular Weight
44.01 g/mol
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Zorg voor een goede ventilatie en/of een lokale afzuiging om een accumulatie van concentraties te voorkomen die de blootstellinglimieten overschrijden. Er moeten makkelijk toegankelijke stations voor het uitwassen van de ogen en veiligheidsdouches beschikbaar zijn. Zorg voor een natuurlijke of een explosievrije ventilatie om de concentraties onder de limieten te houden.

Hand Protection

Ondoorlatende handschoenen die bestand zijn tegen chemicalin en voldoen aan een goedgekeurde norm, dienen te allen tijde te worden gedragen bij het hanteren van chemicalin, indien de noodzaak hiertoe blijkt uit een risicoanalyse. Gepaste, thermisch gesoleerde of leren handschoenen . Standaard EN 511- koude isolerende handschoenen.

Eye Protection

veiligheidsbril

Environmental Exposure Controls

Raadpleeg de uitgebreide sectie van het VIB voor meer informatie over de CSA, indien van toepassing.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Proper Shipping Name

Carbon dioxide, solid

Packing Group

Niet van toepassing.

ADR Transport Precautions

Niet-gevaarlijke goederen

IMDG Maritime Transport Precautions

Transport verboden

IATA Air Transport Precautions

Passagier - en vrachtvliegtuig : Transport toegestaan Enkel vrachtvliegtuig : Transport toegestaan

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is Droogijs blok 300 x 147 x 155mm known by?

Droogijs blok 300 x 147 x 155mm is also known as: Gasart 370 BIOGON C, E290, Gasart 374 Kohlendioxid, Gasart 375 Kohlendioxid med., Gasart 471 Kltemittel R 744, Gasart 471 Kohlendioxid 4.5, Gasart 472 Kohlendioxid 4.8, Gasart 473 Kohlendioxid 2.0, Kohlendioxid 3.0, Kohlendioxid 5.3, R744

What is the hazard signal word for Droogijs blok 300 x 147 x 155mm?

The signal word for this substance is "no signal word".

What is the physical form of Droogijs blok 300 x 147 x 155mm?

Droogijs blok 300 x 147 x 155mm is a vast. diepgekoeld vast gas. appearing as diepgekoeld vast gas. with wit. color. It has geen geur waarschuwingskenmerken. odor.

What is Droogijs blok 300 x 147 x 155mm used for?

Voedingsindustrie

What is the melting point of Droogijs blok 300 x 147 x 155mm?

The melting point is -70 F (-56.6 C) and the boiling point is Geen gegevens beschikbaar..