Product Name
Fast Glue Filler
Product Code
15120

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Vulmiddel en plamuur
Uses Advised Against
Geen verdere relevante informatie verkrijgbaar.

Overview

Fast Glue Filler commonly used vulmiddel en plamuur.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

PROMANTE sa

manufacturer

Gruuss-Strooss 53/A17 L-9991 Weiswampach

LU

MCS Belgium bv

distributor

Langerode 16 B-3460 Bekkevoort

BE

+32 (0)16 47 37 00

Ex & Tric bv

distributor

Spoorwegstraat 1 B-8854 Sint-Denijs

BE

+32 (0)56 20 69 50

Promant LUX s.a.r.l.

distributor

11, route de Mondorf L-5441 Remerschen

LU

00352 / 26 38 37 31

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

(+32) 070 245 245

BE

24h/d, 7d/wk

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Silicon dioxide N/A 10-75% Hazardous
sodium monoxide
EC: 215-208-9
1313-59-3 5-15% Hazardous
Calcium Oxide
EC: 215-138-9
1305-78-8 10-12% Hazardous
magnesium oxide
EC: 215-171-9
1309-48-4 5% Hazardous
Fumed Alumina
EC: 215-691-6
1344-28-1 2.5% Hazardous
dikaliumoxide
EC: 235-227-6
12136-45-7 1-1.5% Hazardous
Iron (III) oxide (impurity)
EC: 215-168-2
1309-37-1 0.2% Non-hazardous

Additional Information

Raadpleeg hoofdstuk 16 voor de formulering van de genoemde risicozinnen.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden.

Eye Contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen

Ingestion/Swallowing

Als de klachten niet minderen, een arts raadplegen

Immediate Medical Attention Required

Geen verdere relevante informatie verkrijgbaar.

Medical Treatment

Geen verdere relevante informatie verkrijgbaar.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Vast
Critical Property
Physical State Data
solid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Kleurloos
Colour Intensity
Not available
Form
Vast
Odor
Reukloos
Odor Threshold
Niet bepaald.
Ph
Niet bruikbaar.
Melting Point
~730 C
Critical Property
Boiling Point
Niet bepaald.
Critical Property
Flash Point
Niet bruikbaar.
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Niet bruikbaar.
Vapor Pressure
Niet bruikbaar.
Vapor Density
Niet bruikbaar.
Relative Density
Niet bepaald.
Bulk Density
1.500 kg/m
Density
2,45 g/cm
Critical Property
Flammability
Niet bepaald.
Upper Explosive Limit
Niet bepaald.
Lower Explosive Limit
Niet bepaald.
Explosive Limits
Not available
Auto Ignition Temperature
Het produkt ontbrandt niet uit zichzelf.
Decomposition Temperature
Niet bepaald.
Solubility
Not available
Partition Coefficient
Niet bepaald.
Solubility In Water
Niet oplosbaar.
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Niet van toepassing
Dynamic Viscosity
Niet bruikbaar.
Kinematic Viscosity
Niet bruikbaar.
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Op grond van falende testen kan geen aanbeveling voor handschoenmateriaal voor het product / de bereiding / het chemicalinmengsel afgegeven worden. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vr het gebruik worden getest. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Fast Glue Filler?

The signal word for this substance is "no signal word".

What is the physical form of Fast Glue Filler?

Fast Glue Filler is a vast with kleurloos color. It has reukloos odor.

What is Fast Glue Filler used for?

Vulmiddel en plamuur

What is the melting point of Fast Glue Filler?

The melting point is ~730 C and the boiling point is Niet bepaald..