NextSDS Logo
EC

ECO Sanitary Forte

DANGER vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ECO Sanitary Forte

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Sanitairreiniger voor professioneel gebruik (AISE_SUMI_PW_8a_1_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_13_1_G // AISE_SUMI_PW_19_1)

Overview

ECO Sanitary Forte commonly used sanitairreiniger voor professioneel gebruik (aise_sumi_pw_8a_1_g // aise_sumi_pw_10_1 // aise_sumi_pw_13_1_g // aise_sumi_pw_19_1).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Skin Corr. Category 1A H314

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H314: Veroorzaakt emstige brandwonden en oogletsel.

Precautionary Statements

  • P280: Beschernende handschoenen, beschernende kleding, oogbescherming, gelaatsbescherming dragen.
  • P301 + P330 + P331: NA INSLIKKEN: de mond spoelen GEEN braken opwecken.
  • P303 + P361 + P353: BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/afdouchen.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P310: Onmiddellijk een ANTIGIFCENTRUM of een arts raadplegen.
  • P501: Inhoud/verpakking afvoeren volgens de plaatselijke / regionale / nationale / internationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Greenspeed company logo - Safety Data Sheet supplier organization

Greenspeed

distributor

P.O.Box 1250 2280 CG Rijswijk (ZH), NL

NL

+31703458737

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 70 245 245

BE

Emergency Contact

+31 30 274 88 88

NL

Uitsluitend voor professionele hulpverleners

Emergency Contact

+33 (0)1 45 42 59 59

FR

Emergency Contact

(+352) 8002-5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Melkzuur
EC: 200-018-0
50-21-5 7% Non-hazardous
Citroenzuur
EC: 201-069-1
77-92-9 7% Non-hazardous
D-Glucopyranose, oligomeren, 2-ethylhexyl glycosiden
EC: 500-529-1
161074-93-7 5% Non-hazardous

Additional Information

Voor de volledige tekst van de H-zinnen die worden genoemd in deze rubriek, zie rubriek 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Rechtop laten zitten, frisse lucht, rust en naar ziekenhuis vervoeren.

Symptoms:

hoofdpijn, duizeligheid, misselijkheid, sufheid, bewusteloosheid

Skin Contact

Verontreinigde kleding uittrekken, huid spoelen met voor water en onmiddellijk naar ziekenhuis vervoeren.

Symptoms:

bijtend, roodheid, pijn, ernstige brandwonden

Eye Contact

Eerst langdurig spoelen met water (contactlenzen verwijderen mit makkelijk mogelijk), dan naar arts brengen.

Symptoms:

bijtend, roodheid, slecht zien, pijn

Ingestion/Swallowing

Mond laten spoelen, GEEN braken opwekken en onmiddellijk naar ziekenhuis vervoeren.

Symptoms:

bijtend, además, braken, blaren op lippen en tong, brandende pijn in mond en keel, slokdarm en maag

Immediate Medical Attention Required

Steeds zo spoedig mogelijk medisch advies inwinnen in geval van ernstige of aanhoudende stoornissen. Onmiddellijk naar ziekenhuis vervoeren bij huidcontact, inslikken en inademing. Na oogcontact naar arts brengen.

Medical Treatment

geen

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Colour Intensity
Not available
Boiling Point
78 °C — 100 °C
Critical Property
Ph
2,0
Density
Not available
Auto Ignition Temperature
370 °C
Lower Explosive Limit
3,000 %
Freezing Point
Not available
Evaporation Rate
2,000
Metal Corrosion
Not available
Solubility In Water
volledig oplosbaar
Upper Explosive Limit
19,000 %
Colour
Not available
Odor
kenmerkend
Bulk Density
Not available
Physical State
vloeibaar
Critical Property
Solubility
Not available
Melting Point
0 °C
Critical Property
Appearance
Not available
Dynamic Viscosity
400 mPa.s
Vapor Pressure
5 850 Pa
Kinematic Viscosity
381 mm²/s
Cloud Point
Not available
Form
Not available
State Under Standard Conditions
vloeibaar
Solidification Point
Not available
Voc Content
1,00 %
Softening Point
Not available
Flammability
Technisch onmogelijk
Molecular Weight
Not available
Vapor Density
Technisch onmogelijk
Odor Threshold
Technisch onmogelijk
Relative Evaporation Rate
Not available
Partition Coefficient
Technisch onmogelijk
Relative Density
1,0500 kg/l
Properties Status
Not available
Explosive Limits
Not available
Flash Point
I
Critical Property
Physical State Data
liquid
Crystallisation Point
Not available
Decomposition Temperature
I
Solubility In Fat
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Gebruiken met voldoende afzuigventilatie.

Hand Protection

Met Viton-handschoenen (EN 374) hanteren. Minimale doorbraaktijd van > 480 minuten, dikte 0,70mm. Handschoenen voor gebruik goed controleren. Handschoenen netjes uittrekken zonder de buitenkant aan te raken met de blote hand. De geschiktheid voor een specifieke werkplek moet worden overlegd met de fabrikant van de beschemhandschoenen.

Eye Protection

Gebruik een nauw aansluitende veiligheidsbril (EN 166). Een volgelaatsschem en beschermend pak dragen bij uitzonderlijke verwerkingsproblemen.

Respiratory Protection

Waar ademáshaling risico's zich voordoen, gebruik indien nodig een luchtzuiverend volgelaatsmasker. Als bescherming tegen deze belastende niveau, gebruik type ABEK.

Skin/Body Protection

Gebruik niet doorlaatbare beschernende kleding die bestand is tegen dit product. De keuze van specifieke onderdelen zoals gelaatsmasker, handschoenen, laarzen, schort of volledig pak hangt af van de werkzaamheden.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Extrem hoge of lage temperaturen vermijden.

Reactivity

Stabiel oder normale omstandigheden.

Hazardous Reactions

geen

Conditions to Avoid

Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50°C

Incompatible Materials

zuren, basen, oxidatiemiddelen, reductiemiddelen

Hazardous Decomposition Products

Onder de aanbevolen gebruiksomstandigheden worden een gevaarlijke ontledingsproducten verwacht.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

3265

Proper Shipping Name

Bijtende zure organische vloeistof, n.e.g. (mengsel met Melkzuur)

Transport Hazard Class

8

Packing Group

ADR Transport Precautions

Risico op brandwonden. Risico voor het aquatisch milieu en de afvoerstelsels voor afvalwater. Verhinderen dat weglekkende stoffen bij een ongeval in het aquatisch milieu of in het rioolstelsel terechtkomen. Het gemorste product zoveel mogelijk indijken met inert materiaal.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ECO Sanitary Forte?

The signal word for this substance is "danger".

What is the physical form of ECO Sanitary Forte?

ECO Sanitary Forte is a vloeibaar . It has kenmerkend odor.

What is ECO Sanitary Forte used for?

Sanitairreiniger voor professioneel gebruik (AISE_SUMI_PW_8a_1_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_13_1_G // AISE_SUMI_PW_19_1)

What are the hazard statements for ECO Sanitary Forte?

This substance has 1 hazard statements: H314: Veroorzaakt emstige brandwonden en oogletsel.

What is the melting point of ECO Sanitary Forte?

The melting point is 0 °C and the boiling point is 78 °C — 100 °C.