NextSDS Logo
Ro

Roam Floc

NO SIGNAL WORD Vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Roam Floc
Product Form
Oplossing

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Vlokmiddel Waterbehandeling

Overview

Roam Floc is a vloeistof. substance commonly used vlokmiddel waterbehandeling.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Roam Chemie bvba company logo - Safety Data Sheet supplier organization

Roam Chemie bvba

manufacturer

Industrieterrein Centrum-Zuid 2053 3530 Houthalen - Belgium

BE

+32 (0)11 60 29 78

32 (0)11 60 29 79

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Anti-Poisons/Antigifcentrum

+32 70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
dialuminiumchloridepentahydroxide 12042-91-0 7.12-7.43% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Breng het slachtoffer in de frisse lucht. Bij ademhalingsproblemen: arts/medische dienst raadplegen.

Symptoms:

BIJ BLOOTSTELLING AAN HOGE CONCENTRATIES: Hoesten. Irritatie luchtwegen. Neusslijmvliesirritatie.

Skin Contact

Onmiddellijk met veel water spoelen. Gebruik van zeep toegestaan. Slachtoffer naar arts brengen als irritatie aanhoudt.

Symptoms:

NA LANGDURIGE BLOOTSTELLING/CONTACT: Prikkeling/irritatie van de huid.

Eye Contact

Onmiddellijk met veel water spoelen. Slachtoffer naar oogarts brengen als irritatie aanhoudt.

Symptoms:

NA LANGDURIGE BLOOTSTELLING/CONTACT: Irritatie van het oogweefsel.

Ingestion/Swallowing

Mond spoelen met water. Zo vlug mogelijk na inname: veel water laten drinken. Niet laten braken. Indien men zich onwel voelt: medische dienst/arts raadplegen. Bij inname van grote hoeveelheden: snel naar ziekenhuis.

Symptoms:

Mondslijmvliesirritatie. Droge keel/keelpijn. Maag-/darmklachten.

Immediate Medical Attention Required

Afhankelijk van de toestand: arts/ziekenhuis. Bij ademhalingsproblemen: arts/medische dienst raadplegen. Slachtoffer naar arts brengen als irritatie aanhoudt (huid). Slachtoffer naar oogarts brengen als irritatie aanhoudt (ogen). Indien men zich onwel voelt: medische dienst/arts raadplegen. Bij inname van grote hoeveelheden: snel naar ziekenhuis.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Blusmiddelen aanpassen aan omgeving.

Unsuitable Extinguishing Media

Geen te mijden blusmiddelen gekend.

Specific Fire Hazards

Brandgevaar: DIRECT BRANDGEVAAR. Niet brandbaar. Explosiegevaar: DIRECT EXPLOSIEGEVAAR. Geen gegevens beschikbaar i.v.m. direct explosiegevaar. INDIRECT EXPLOSIEGEVAAR. Geen gegevens beschikbaar i.v.m. indirect explosiegevaar.

Fire Fighting Instructions

Toxische gassen verdunnen met verneveld water.

Firefighter Protection Equipment

Bij verhitting/verbranding: ademluchttoestel.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Gevarenzone afbakenen. Geen open vuur. Verontreinigde kleding reinigen.

Cleanup Methods

Morsvloeistof absorberen in absorptiemiddel. Geabsorbeerd product opscheppen in afsluitbare vaten. Bevuilde oppervlakten reinigen met een overmaat water. Na werkzaamheden kleding en materiaal reinigen.

Cleanup Materials:

absorptiemiddel

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solubility In Fat
Not available
Flash Point
Niet van toepassing
Critical Property
Density
Not available
Solubility In Water
Not available
Cloud Point
Not available
State Under Standard Conditions
Not available
Properties Status
Not available
Softening Point
Not available
Physical State
Vloeibaar
Critical Property
Vapor Pressure
Geen gegevens beschikbaar
Crystallisation Point
Not available
Boiling Point
110 - 115 °C
Critical Property
Form
Not available
Relative Evaporation Rate
Geen gegevens beschikbaar
Explosive Limits
Not available
Dynamic Viscosity
Geen gegevens beschikbaar
Lower Explosive Limit
Not available
Bulk Density
Not available
Auto Ignition Temperature
Niet van toepassing
Colour
Kleurloos.
Metal Corrosion
Not available
Voc Content
Niet van toepassing
Relative Density
1,3 (25 °C)
Odor Threshold
Geen gegevens beschikbaar
Flammability
Geen gegevens beschikbaar
Kinematic Viscosity
Geen gegevens beschikbaar
Decomposition Temperature
Geen gegevens beschikbaar
Ph
4,0 - 4,4 (30 %)
Solidification Point
Geen gegevens beschikbaar
Colour Intensity
Not available
Melting Point
Geen gegevens beschikbaar
Critical Property
Freezing Point
Geen gegevens beschikbaar
Molecular Weight
174,46 g/mol
Solubility
Geen gegevens beschikbaar
Appearance
Vloeistof.
Vapor Density
Not available
Partition Coefficient
Geen gegevens beschikbaar
Physical State Data
liquid
Upper Explosive Limit
Not available
Odor
Reukloos.
Evaporation Rate
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

In orde met de wettelijke normen.

Verontreinigde kleding onmiddellijk uittrekken.

Verontreinigde kleding reinigen.

Verwijderd houden van open vuur/warmte.

Strenge hygiëne.

Regelmatig concentratie in de lucht meten.

Werken in open lucht/onder plaatselijke afzuiging/met ventilatie of met ademhalingsbescherming.

Storage Conditions

In orde met de wettelijke normen.

PRODUCT VERWIJDERD HOUDEN VAN: warmtebronnen.

General Hygiene Measures

Verontreinigde kleding onmiddellijk uittrekken. Verontreinigde kleding reinigen. Strenge hygiëne.

Fire Prevention Measures

Verwijderd houden van open vuur/warmte.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Handschoenen

Eye Protection

Veiligheidsbril

Respiratory Protection

Bij ontoereikende ventilatie: adembescherming dragen

Skin/Body Protection

Beschermkleding

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stabiel onder normale omstandigheden.

Reactivity

Bij verhitting/verbranding: vorming van giftige en bijtende gassen/dampen (waterstofchloride).

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Product Disposal Recommendations

Afvoeren naar erkende afvalverwerker.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Proper Shipping Name

Niet van toepassing

Transport Hazard Class

Niet van toepassing

Packing Group

Niet van toepassing

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Roam Floc?

The signal word for this substance is "no signal word".

What is the physical form of Roam Floc?

Roam Floc is a vloeibaar appearing as vloeistof. with kleurloos. color. It has reukloos. odor.

What is the solubility of Roam Floc?

Geen gegevens beschikbaar

What is Roam Floc used for?

Vlokmiddel Waterbehandeling

What is the melting point of Roam Floc?

The melting point is Geen gegevens beschikbaar and the boiling point is 110 - 115 °C.