NextSDS Logo
Co

Copagro Cellulose thinner

DANGER Vloeibare vloeistof. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Copagro Cellulose thinner
Product Code
CHCT

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

Copagro Cellulose thinner .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (GEVAAR)

Hazard Classifications

Flam. Liq. Category 2 H225
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
Repr. Category 2 H361
STOT SE Category 3 H336
STOT RE Category 2 H373
Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Licht ontvlambare vloeistof en damp.
  • H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt.
  • H315: Veroorzaakt huidirritatie.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H361: Wordt ervan verdacht het ongeboren kind te schaden.
  • H373: Kan schade aan organen veroorzaken bij langdurige of herhaalde blootstelling (door inademing).

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte/vonken/open vuur/hete oppervlakken. — Niet roken.
  • P271: Alleen buiten of in een goed geventileerde ruimte gebruiken.
  • P280: Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
  • P301 + P310: NA INSLIKKEN: onmiddellijk een ANTIGIFCENTRUM of een arts raadplegen.
  • P302 + P352: BIJ CONTACT MET DE HUID: met veel water en zeep wassen.
  • P304 + P340: NA INADEMING: het slachtoffer in de frisse lucht brengen en laten rusten in een houding die het ademen vergemakkelijkt.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P312: Bij onwel voelen een ANTIGIFCENTRUM of een arts raadplegen.
  • P331: GEEN braken opwekken.
  • P501: De inhoud en / verpakking verwerken volgens de plaatselijke / regionale / nationale / internationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Copagro CV..

distributor

Pachtgoedstraat 1 9140 Temse.Belgique.

BE

+32(0)37600010

+32(0)37600019

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum België, centre anti-poison.

070 245 245.

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Samenstelling :

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
TOLUEEN
EC: 203-625-9
108-88-3 50-100% Hazardous
ACETON
EC: 200-662-2
67-64-1 25-50% Hazardous

Composition Notes

[1] Stof waarvoor grenswaarden voor blootstelling op de werkplek bestaan. [2] Kankerverwekkende, mutagene of reproductietoxische stof (CMR).

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

De persoon van de verontreinigde atmosfeer onmiddellijk verwijderen en een arts noemen.

Symptoms:

De inademing van stoom met sterke concentratie heeft een narcotische reactie op het centrale zenuwstelsel tot gevolg.

Skin Contact

Verwijder verontreinigde kleding en was de huid grondig met water en zeep.

Symptoms:

Irriterend voor de huid. Irritatie.

Eye Contact

Onmiddellijk en zich overvloedig aan het water wassen, door de oogleden te verwijderen, gedurende verschillende minuten.

Symptoms:

Irriterend voor de ogen. Irritatie.

Ingestion/Swallowing

Onmiddellijk een dokter bellen, wijzend op het productlabel.

Symptoms:

In geval van inname gevolgd door braken, kan het product in de longen doordringen. In geval van toevallige inname, kan het product in de longen door zijn geringe viscositeit gestreefd worden en een ernstig longletsel in de uren veroorzaken die volgen.

Immediate Medical Attention Required

In het algemeen, ingeval van twijfel of indien de verschijnselen aanhouden, altijd een arts waarschuwen. Als een irritatie, ophtalmologiste raadplegen voortduurt. Als irritatie optreedt of als de verontreiniging is op grote schaal en langdurig, een arts raadplegen. Onmiddellijk een dokter bellen, wijzend op het productlabel.

Medical Treatment

Geen gegevens beschikbaar.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

schuim, kooldioxide (CO2), poeder droog

Unsuitable Extinguishing Media

waterspuit

Specific Fire Hazards

In geval van brand, kan zich vormen: koolmonoxide (CO), kooldioxide (CO2).

Fire Fighting Instructions

Koel de containers / vuilwatertank, sproeistraal van water.

Firefighter Protection Equipment

De sprekers zullen worden uitgerust met autonome ademhaling isolerende bescherming. Draag beschermende kleding en uitrusting voor brandvertragend.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Raadpleeg de beschermingsmaatregelen die in de rubrieken 7 en 8 vermeld staan

Environmental Precautions

Vermijd het binnendruipen in de rioleringen en waterlopen. de stortingen aan de bevoegde instanties aanduiden, overeenkomstig de reglementering geldend.

Cleanup Methods

Verwijderen met inachtneming van de voorschriften.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Upper Explosive Limit
Not available
Dynamic Viscosity
Not available
Molecular Weight
Not available
Ph
niet van toepassing.
Freezing Point
Not available
Solubility
Not available
Colour Intensity
Not available
Form
Not available
Melting Point
niet nader uiteengezet.
Critical Property
Colour
Not available
Solidification Point
Not available
Softening Point
Not available
Flammability
Not available
Odor
Not available
Properties Status
Not available
Density
Not available
Cloud Point
Not available
Auto Ignition Temperature
niet nader uiteengezet.
Physical State
Vloeibare vloeistof.
Critical Property
Vapor Pressure
lager dan 110kPa(1,10 bar)
Metal Corrosion
Not available
Kinematic Viscosity
v < 7 mm2/s(40°C)
Physical State Data
liquid
Bulk Density
Not available
Relative Evaporation Rate
Not available
Lower Explosive Limit
Not available
Partition Coefficient
Not available
Vapor Density
Not available
Crystallisation Point
Not available
Decomposition Temperature
niet nader uiteengezet.
State Under Standard Conditions
Not available
Relative Density
< 1
Boiling Point
> 35°C
Critical Property
Appearance
Not available
Solubility In Fat
Not available
Voc Content
Not available
Explosive Limits
Not available
Flash Point
PE > 23°C
Critical Property
Solubility In Water
Onoplosbaar.
Evaporation Rate
Not available
Odor Threshold
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

De voorschriften met betrekking tot de opslagruimtes zijn van toepassing op de werkplaatsen waar het mengsel verwerkt wordt.

Zwangere vrouwen mogen niet aan dergelijke producten blootgesteld worden; verwittig alle vrouwen van de mogelijke risicos.

Hanteren in goed geventileerde plaatsen gebruiken.

Zie onderdeel 8 voor persoonlijke beschermingsmiddelen.

Storage Conditions

Bewaar het vat goed gesloten in een koele, goed geventileerde ruimte.

Verwijderd houden van elke ontsteking en warmtebron alsmede tegen elke rechtstreekse bestraling door de zon.

Fire Prevention Measures

Verwijderd houden van elke ontsteking en warmtebron

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Gebruik geschikte beschermende handschoenen die bestand zijn tegen chemische stoffen en voldoen aan de norm EN374.

Eye Protection

Voor het hanteren moet een veiligheidsbril met zijbescherming worden opgezet die voldoet aan de norm EN166. Veiligheidsbrillen met zijbeschermingen dragen.

Respiratory Protection

Als de arbeiders te maken krijgen met concentraties die de blootstellingsgrenzen overschrijden moeten ze een geschikte en goedgekeurd ademhalingsbeschermingsmiddel dragen. Filter(s) tegen gas en dampen (gecombineerde filters) volgens de norm EN14387

Skin/Body Protection

Draag een gepaste werkkleding.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Dit mengsel is stabiel onder de in onderdeel 7 aanbevolen omstandigheden voor verwerking en opslag.

Reactivity

Zie de rubrieken hieronder.

Hazardous Reactions

Geen gegevens beschikbaar.

Conditions to Avoid

Voorkom : - zelfverhitting - warmte - vlammen en warme oppervlakken -sparks

Incompatible Materials

Buiten bereik houden van : - zuren - sterke oxideermiddelen

Hazardous Decomposition Products

De thermische ontleding kan ontwikkelen/vormen : - koolmonoxide (CO) - kooldioxide (CO2)

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Niet in de rioleringen of de waterlopen lozen. Volgens de geldende wetgeving laten recycleren of vernietigen, bij voorkeur door een erkende inzamelaar of onderneming.

Product Disposal Recommendations

Het afvalbeheer vindt plaats zonder de menselijke gezondheid of het milieu te schaden, en met name zonder gevaar op te leveren voor het water, de lucht, de bodem, de fauna of flora. De grond of het water niet met het afval vervuilen, deze niet vernietigen in het milieu.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1993

Proper Shipping Name

BRANDBARE VLOEISTOF, N.E.G.

Transport Hazard Class

3

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Copagro Cellulose thinner?

The signal word for this substance is "danger".

What is the physical form of Copagro Cellulose thinner?

Copagro Cellulose thinner is a vloeibare vloeistof. .

What are the hazard statements for Copagro Cellulose thinner?

This substance has 7 hazard statements: H225: Licht ontvlambare vloeistof en damp. H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt. H315: Veroorzaakt huidirritatie. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H361: Wordt ervan verdacht het ongeboren kind te schaden. H373: Kan schade aan organen veroorzaken bij langdurige of herhaalde blootstelling (door inademing).

What is the melting point of Copagro Cellulose thinner?

The melting point is niet nader uiteengezet. and the boiling point is > 35°C.