NextSDS Logo
Wh

White Ultra Lube 34403

NO SIGNAL WORD Aërosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
White Ultra Lube 34403
Product Form
Aerosol
Product Code
34403

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Professioneel en industrieel smeervet

Overview

White Ultra Lube 34403 commonly used professioneel en industrieel smeervet.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Aerosol H222
Skin Irrit. H315
Eye Irrit. H319
STOT SE H336
Aquatic Chronic H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P304 + P340: NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122 °F.
  • P501: De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

KENT Belux SPRL/BVBA

manufacturer

📍

Rue Emile Francqui 4 B-1435 Mont-Saint-Guibert

🌍

BE

KENT Nederland BV

distributor

📍

Claudius Prinsenlaan 128 NL-4818 CP Breda

🌍

NL

📞

+31 85 4868360

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+ 32 10 48 76 40

🌍

BE

🕒

tussen 08.15 en 16.45 uur

Antigifcentrum

📞

070 245 245

🌍

BE

🕒

24 uur op 24

Nationaal vergiftigingen informatie centrum (NVIC)

📞

+31 (0) 30 274 8888

🌍

NL

💡

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butaan, zuiver
EC: 203-448-7
106-97-8 25-50% ✓ Non-hazardous
Koolwaterstoffen, C6-C7, n-alkanen, isoalkanen, cyclische, <5% nhexane
EC: 921-024-6
N/A 10-25% ✓ Non-hazardous
pentaan
EC: 203-692-4
109-66-0 10-25% ✓ Non-hazardous
propaan vloeibaargemaakt
EC: 200-827-9
74-98-6 1-10% ✓ Non-hazardous
calciumdihydroxide
EC: 215-137-3
1305-62-0 2.5% ✓ Non-hazardous
2-propanol
EC: 200-661-7
67-63-0 2.5% ✓ Non-hazardous
1-methoxypropaan-2-ol
EC: 203-539-1
107-98-2 5% ✓ Non-hazardous

Additional Information

De vermelde indeling en etikettering voor deze stof geldt voor de gevaarlijke eigenschap (pen) aangegeven door de waarschuwingszin (nen) in combinatie met de categorie (ën) van gevaar De uiteindelijke etiketten moeten de voorschriften van punt 7 van bijlage VI van deze richtlijn aantonen. Nota: P is toepasbaar voor het product op één of meerdere van zijn componenten. De benzeenconcentratie is <0.1% (w/w%)

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Frisse lucht toevoeren; bij klachten arts opzoeken

🖐️ Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen.

👁️ Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

🍽️ Ingestion/Swallowing

Geen braken teweegbrengen en onmiddellijk bijstand van arts inroepen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Softening Point
Not available
👃 Odor
karakteristiek
👁️ Appearance
Not available
📊 Kinematic Viscosity
Not available
📊 Crystallisation Point
Not available
📊 Vapor Density
Not available
📊 Voc Content
527g/l VOC
📊 Partition Coefficient
Not available
🧊 Melting Point
niet bepaald
Critical Property
🧪 Physical State
Aërosol
Critical Property
💨 Evaporation Rate
Not available
📊 Solubility In Water
niet oplosbaar
📊 Relative Evaporation Rate
Not available
🔥 Flammability
Not available
📊 Properties Status
Not available
📊 Metal Corrosion
Not available
📊 Upper Explosive Limit
20.0 Vol %
📊 Bulk Density
Not available
📊 Dynamic Viscosity
Not available
🎨 Colour
witachtig
📊 Lower Explosive Limit
0.8 Vol %
⚖️ Density
0.637 g/cm³
Critical Property
📊 Solidification Point
Not available
📊 State Under Standard Conditions
Not available
📊 Relative Density
Not available
💧 Solubility
Not available
📊 Form
Aërosol
📊 Freezing Point
niet bepaald
📊 Explosive Limits
Not available
💨 Boiling Point
Vanwege aerosol niet bruikbaar
Critical Property
🧪 Ph
Not available
📊 Auto Ignition Temperature
Het produkt is niet uit zichzelf ontbrandend.
📊 Physical State Data
aerosol
📊 Molecular Weight
Not available
📊 Decomposition Temperature
Not available
📊 Solubility In Fat
Not available
📊 Cloud Point
Not available
📊 Colour Intensity
Not available
💨 Vapor Pressure
2100 hPa
📊 Odor Threshold
Not available
🔥 Flash Point
Vanwege aerosol niet bruikbaar
Critical Property

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Aanvullende gegevens m.b.t. de inrichting van technische installaties: Geen aanvullende gegevens. Zie 7.

🧤 Hand Protection

Veiligheidshandschoenen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Op grond van falende testen kan geen aanbeveling voor handschoenmateriaal voor het product / de bereiding / het chemicaliënmengsel afgegeven worden. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Handschoenmateriaal Nitrielrubber. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vóór het gebruik worden getest. Waarde voor de permeatie: Level 6 ≤ 480 minutes. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.

👁️ Eye Protection

Niet noodzakelijk.

😷 Respiratory Protection

Alleen bij spuiten zonder voldoende afzuiging. Filter A/P2.

🦺 Skin/Body Protection

Draag geschikte beschermende arbeidskleding.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Geen ontleding bij gebruik volgens voorschrift.

⚗️ Reactivity

Geen verdere relevante informatie verkrijgbaar.

⚠️ Hazardous Reactions

Geen gevaarlijke reacties bekend.

🚫 Conditions to Avoid

Geen verdere relevante informatie verkrijgbaar.

🧪 Incompatible Materials

Geen verdere relevante informatie verkrijgbaar.

💨 Hazardous Decomposition Products

Geen gevaarlijke ontbindingsprodukten bekend.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

📦 Proper Shipping Name

SPUITBUSSEN

📋 Packing Group

vervalt

🚛 ADR Transport Precautions

Waarschuwing: Gassen

🚢 IMDG Maritime Transport Precautions

Waarschuwing: Gassen

✈️ IATA Air Transport Precautions

Waarschuwing: Gassen

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for White Ultra Lube 34403?

The signal word for this substance is "no signal word".

What is the physical form of White Ultra Lube 34403?

White Ultra Lube 34403 is a aërosol with witachtig color. It has karakteristiek odor.

What is White Ultra Lube 34403 used for?

Professioneel en industrieel smeervet

What is the melting point of White Ultra Lube 34403?

The melting point is niet bepaald and the boiling point is Vanwege aerosol niet bruikbaar.