NextSDS Logo
Ru

Rusty Shock Spray

DANGER Aërosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Rusty Shock Spray
Product Code
84599

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
M69J-C7PP-E00N-E1K1

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Kruipolie

Overview

Rusty Shock Spray commonly used kruipolie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
STOT SE Category 3 H336
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H412: Schadelijk voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P260: Nevel/damp/spuitnevel niet inademen.
  • P280: Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
  • P302 + P352: BIJ CONTACT MET DE HUID: Met veel water en zeep wassen.
  • P304 + P340: NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122 °F.
  • P501: De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

KENT Belux SPRL/BVBA

manufacturer

Rue Emile Francqui 4 B-1435 Mont-Saint-Guibert

BE

KENT Nederland BV

manufacturer

Claudius Prinsenlaan 128 NL-4818 CP Breda

NL

+31 85 4868360

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+ 32 10 48 76 40

BE

tussen 08.15 en 16.45 uur

Antigifcentrum

070 245 245

BE

24 uur op 24

Nationaal vergiftigingen informatie centrum (NVIC)

+31 (0) 30 274 8888

NL

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butaan, zuiver
EC: 203-448-7
106-97-8 50-75% Hazardous
propaan vloeibaargemaakt
EC: 200-827-9
74-98-6 10-25% Hazardous
N/A N/A 10-25% Hazardous
kerosine(aardolie)
EC: 232-366-4
8008-20-6 2.5% Hazardous
Aceton
EC: 200-662-2
67-64-1 5% Hazardous
Imidazoline 21652-27-7 0.5% Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16. Nota: P is toepasbaar voor het product op één of meerdere van zijn componenten. De benzeenconcentratie is <0.1% (w/w%)

Composition Notes

Nota: P is toepasbaar voor het product op n of meerdere van zijn componenten. De benzeenconcentratie is <0.1% (w/w%)

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Frisse lucht toevoeren; bij klachten arts opzoeken

Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen. Wanneer de huid geïrriteerd blijft, een dokter opzoeken.

Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Ingestion/Swallowing

Geen braken teweegbrengen en onmiddellijk bijstand van arts inroepen.

Immediate Medical Attention Required

Geen verdere relevante informatie verkrijgbaar.

Medical Treatment

Geen verdere relevante informatie verkrijgbaar.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

CO2, bluspoeder of waternevel. Grotere brand met waternevel of met schuim dat tegen alcohol bestand is bestrijden.

Unsuitable Extinguishing Media

Krachtige waterstraal.

Fire Fighting Instructions

De aan gevaar blootgestelde tanks met watersproeistraal koelen.

Firefighter Protection Equipment

Ontploffings- en brandgassen niet inademen. Adembeschermingsapparaat dragen dat niet afhankelijk is van de omgevingslucht.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Beschermende kleding aantrekken. Niet beschermde personen op afstand houden.

Environmental Precautions

Bij indringen in afvalwater of riolering is de bevoegde instantie te waarschuwen. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Cleanup Methods

Met vloeistofbindend materiaal (zand, bergmeel, zuurbinder, universele binder, zaagmeel) opnemen. Besmet materiaal zoals afval volgens punt 13 verwijderen.

Cleanup Materials:

vloeistofbindend materiaal (zand, bergmeel, zuurbinder, universele binder, zaagmeel)

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solidification Point
Not available
Bulk Density
Not available
Decomposition Temperature
Not available
Relative Evaporation Rate
Not available
Solubility In Fat
Not available
Physical State
Aërosol
Critical Property
Solubility
Not available
Vapor Pressure
8300 hPa
Form
Aërosol
Relative Density
Not available
Odor
karakteristiek
Evaporation Rate
Not available
Density
0,6 g/cm³
Critical Property
State Under Standard Conditions
Not available
Melting Point
niet bepaald
Critical Property
Properties Status
Not available
Voc Content
566g/l VOC
Colour
zwart
Appearance
Not available
Ph
Not available
Auto Ignition Temperature
Het produkt is niet uit zichzelf ontbrandend.
Upper Explosive Limit
10.9 Vol %
Physical State Data
aerosol
Vapor Density
Not available
Molecular Weight
Not available
Odor Threshold
Not available
Crystallisation Point
Not available
Lower Explosive Limit
0.8 Vol %
Metal Corrosion
Not available
Flash Point
Vanwege aerosol niet bruikbaar
Critical Property
Colour Intensity
Not available
Softening Point
Not available
Kinematic Viscosity
Not available
Solubility In Water
niet resp. gering mengbaar
Partition Coefficient
Not available
Freezing Point
niet bepaald
Dynamic Viscosity
Not available
Boiling Point
Vanwege aerosol niet bruikbaar
Critical Property
Flammability
Het produkt is niet uit zichzelf ontbrandend.
Cloud Point
Not available
Explosive Limits
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Voor goede ventilatie/afzuiging op de arbeidsplaatsen zorgen.

Tanks voorzichtig openen en behandelen.

Storage Conditions

Op een koele plaats bewaren.

De overheidsbepalingen m.

b.

t.

de opslag van drukgaspakkingen moeten in acht genomen worden.

Tegen hitte en directe zonnestralen beschermen.

Tank op een goed geventileerde plaats bewaren.

Fire Prevention Measures

Onststekingsbronnen op afstand houden - niet roken. Maatregelen treffen tegen ontlading van statische elektriciteit. Attentie: De tank staat onder druk. Beschermen tegen directe zonbestaling en temperaturen boven 50°C. Zelfs na het verbruik niet met geweld openen of verbranden. Niet in open vuur of op gloeiende voorwerpen sproeien.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Voor goede ventilatie/afzuiging op de arbeidsplaatsen zorgen. Alleen bij spuiten zonder voldoende afzuiging is ademhalingsbescherming nodig.

Hand Protection

Veiligheidshandschoenen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Op grond van falende testen kan geen aanbeveling voor handschoenmateriaal voor het product / de bereiding / het chemicaliënmengsel afgegeven worden. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Handschoenmateriaal: Nitrielrubber. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vóór het gebruik worden getest. Waarde voor de permeatie: Level 6 ≤ 480 minutes. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.

Eye Protection

Niet noodzakelijk.

Respiratory Protection

Alleen bij spuiten zonder voldoende afzuiging. Short term filter device: filter AX

Skin/Body Protection

Draag geschikte beschermende kleding.

Environmental Exposure Controls

Bij indringen in afvalwater of riolering is de bevoegde instantie te waarschuwen. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen. Het besmette bluswater afzonderlijk verzamelen, mag niet in de riolering terechtkomen.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Geen ontleding bij gebruik volgens voorschrift.

Reactivity

Geen verdere relevante informatie verkrijgbaar.

Hazardous Reactions

Geen gevaarlijke reacties bekend.

Conditions to Avoid

Geen verdere relevante informatie verkrijgbaar.

Incompatible Materials

Geen verdere relevante informatie verkrijgbaar.

Hazardous Decomposition Products

Geen gevaarlijke ontbindingsprodukten bekend.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Product Disposal Recommendations

Mag niet tesamen met huisvuil gestort worden of in de riolering komen.

Waste Classification Codes

15 01 04 metalen verpakking EWC
HP 3 Ontvlambaar HP code
HP 14 Ecotoxisch HP code
Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1950

Proper Shipping Name

SPUITBUSSEN

Transport Hazard Class

2

Packing Group

vervalt

ADR Transport Precautions

Waarschuwing: Gassen

IMDG Maritime Transport Precautions

Waarschuwing: Gassen

IATA Air Transport Precautions

Waarschuwing: Gassen

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Rusty Shock Spray?

The signal word for this substance is "danger".

What is the physical form of Rusty Shock Spray?

Rusty Shock Spray is a aërosol with zwart color. It has karakteristiek odor.

What is Rusty Shock Spray used for?

Kruipolie

What are the hazard statements for Rusty Shock Spray?

This substance has 6 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H412: Schadelijk voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of Rusty Shock Spray?

The melting point is niet bepaald and the boiling point is Vanwege aerosol niet bruikbaar.