Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Unique Formula Identifier - for poison centres and emergency response
Uses Information
Overview
Rusty Shock Spray commonly used kruipolie.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
- H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
- H315: Veroorzaakt huidirritatie.
- H319: Veroorzaakt ernstige oogirritatie.
- H336: Kan slaperigheid of duizeligheid veroorzaken.
- H412: Schadelijk voor in het water levende organismen, met langdurige gevolgen.
Precautionary Statements
- P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
- P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
- P251: Ook na gebruik niet doorboren of verbranden.
- P260: Nevel/damp/spuitnevel niet inademen.
- P280: Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
- P302 + P352: BIJ CONTACT MET DE HUID: Met veel water en zeep wassen.
- P304 + P340: NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
- P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
- P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122 °F.
- P501: De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
KENT Belux SPRL/BVBA
manufacturer
Rue Emile Francqui 4 B-1435 Mont-Saint-Guibert
BE
KENT Nederland BV
manufacturer
Claudius Prinsenlaan 128 NL-4818 CP Breda
NL
+31 85 4868360
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+ 32 10 48 76 40
BE
tussen 08.15 en 16.45 uur
Antigifcentrum
070 245 245
BE
24 uur op 24
Nationaal vergiftigingen informatie centrum (NVIC)
+31 (0) 30 274 8888
NL
Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| butaan, zuiver EC: 203-448-7 | 106-97-8 | 50-75% | Hazardous |
| propaan vloeibaargemaakt EC: 200-827-9 | 74-98-6 | 10-25% | Hazardous |
| N/A | N/A | 10-25% | Hazardous |
| kerosine(aardolie) EC: 232-366-4 | 8008-20-6 | 2.5% | Hazardous |
| Aceton EC: 200-662-2 | 67-64-1 | 5% | Hazardous |
| Imidazoline | 21652-27-7 | 0.5% | Hazardous |
Additional Information
De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16. Nota: P is toepasbaar voor het product op één of meerdere van zijn componenten. De benzeenconcentratie is <0.1% (w/w%)
Composition Notes
Nota: P is toepasbaar voor het product op n of meerdere van zijn componenten. De benzeenconcentratie is <0.1% (w/w%)
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
Frisse lucht toevoeren; bij klachten arts opzoeken
Skin Contact
Onmiddellijk met water en zeep afwassen en goed naspoelen. Wanneer de huid geïrriteerd blijft, een dokter opzoeken.
Eye Contact
De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.
Ingestion/Swallowing
Geen braken teweegbrengen en onmiddellijk bijstand van arts inroepen.
Immediate Medical Attention Required
Geen verdere relevante informatie verkrijgbaar.
Medical Treatment
Geen verdere relevante informatie verkrijgbaar.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
Suitable Extinguishing Media
CO2, bluspoeder of waternevel. Grotere brand met waternevel of met schuim dat tegen alcohol bestand is bestrijden.
Unsuitable Extinguishing Media
Krachtige waterstraal.
Fire Fighting Instructions
De aan gevaar blootgestelde tanks met watersproeistraal koelen.
Firefighter Protection Equipment
Ontploffings- en brandgassen niet inademen. Adembeschermingsapparaat dragen dat niet afhankelijk is van de omgevingslucht.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
Emergency Procedures
Beschermende kleding aantrekken. Niet beschermde personen op afstand houden.
Environmental Precautions
Bij indringen in afvalwater of riolering is de bevoegde instantie te waarschuwen. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.
Cleanup Methods
Met vloeistofbindend materiaal (zand, bergmeel, zuurbinder, universele binder, zaagmeel) opnemen. Besmet materiaal zoals afval volgens punt 13 verwijderen.
Cleanup Materials:
vloeistofbindend materiaal (zand, bergmeel, zuurbinder, universele binder, zaagmeel)
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
Handling Precautions
• Voor goede ventilatie/afzuiging op de arbeidsplaatsen zorgen.
• Tanks voorzichtig openen en behandelen.
Storage Conditions
• Op een koele plaats bewaren.
• De overheidsbepalingen m.
• b.
• t.
• de opslag van drukgaspakkingen moeten in acht genomen worden.
• Tegen hitte en directe zonnestralen beschermen.
• Tank op een goed geventileerde plaats bewaren.
Fire Prevention Measures
Onststekingsbronnen op afstand houden - niet roken. Maatregelen treffen tegen ontlading van statische elektriciteit. Attentie: De tank staat onder druk. Beschermen tegen directe zonbestaling en temperaturen boven 50°C. Zelfs na het verbruik niet met geweld openen of verbranden. Niet in open vuur of op gloeiende voorwerpen sproeien.
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Voor goede ventilatie/afzuiging op de arbeidsplaatsen zorgen. Alleen bij spuiten zonder voldoende afzuiging is ademhalingsbescherming nodig.
Hand Protection
Veiligheidshandschoenen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Op grond van falende testen kan geen aanbeveling voor handschoenmateriaal voor het product / de bereiding / het chemicaliënmengsel afgegeven worden. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Handschoenmateriaal: Nitrielrubber. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vóór het gebruik worden getest. Waarde voor de permeatie: Level 6 ≤ 480 minutes. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.
Eye Protection
Niet noodzakelijk.
Respiratory Protection
Alleen bij spuiten zonder voldoende afzuiging. Short term filter device: filter AX
Skin/Body Protection
Draag geschikte beschermende kleding.
Environmental Exposure Controls
Bij indringen in afvalwater of riolering is de bevoegde instantie te waarschuwen. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen. Het besmette bluswater afzonderlijk verzamelen, mag niet in de riolering terechtkomen.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
Chemical Stability
Geen ontleding bij gebruik volgens voorschrift.
Reactivity
Geen verdere relevante informatie verkrijgbaar.
Hazardous Reactions
Geen gevaarlijke reacties bekend.
Conditions to Avoid
Geen verdere relevante informatie verkrijgbaar.
Incompatible Materials
Geen verdere relevante informatie verkrijgbaar.
Hazardous Decomposition Products
Geen gevaarlijke ontbindingsprodukten bekend.
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
Product Disposal Recommendations
Mag niet tesamen met huisvuil gestort worden of in de riolering komen.
Waste Classification Codes
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
UN Number
UN1950
Proper Shipping Name
SPUITBUSSEN
Transport Hazard Class
2
Packing Group
vervalt
ADR Transport Precautions
Waarschuwing: Gassen
IMDG Maritime Transport Precautions
Waarschuwing: Gassen
IATA Air Transport Precautions
Waarschuwing: Gassen
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Rusty Shock Spray?
The signal word for this substance is "danger".
What is the physical form of Rusty Shock Spray?
Rusty Shock Spray is a aërosol with zwart color. It has karakteristiek odor.
What is Rusty Shock Spray used for?
Kruipolie
What are the hazard statements for Rusty Shock Spray?
This substance has 6 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H412: Schadelijk voor in het water levende organismen, met langdurige gevolgen.
What is the melting point of Rusty Shock Spray?
The melting point is niet bepaald and the boiling point is Vanwege aerosol niet bruikbaar.