NextSDS Logo
Safety Data Sheet NL

GARDOBOND ADDITIVE H 7430

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GARDOBOND ADDITIVE H 7430

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Antischuimmiddel

Uses advised against

Niets bekend.

Manufacturers & Suppliers

C

Chemetall B.V.

manufacturer

Rue du Bosquet 9, B-1348 Louvain-la-Neuve

32 (0) 3.450.37.10

Emergency Contacts

Emergency Contact

+32(0)70 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Basis, Minerale olie.

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 80 - 100% Yes

Notes

Voor de volledige text van H-zinnen zoals vermeld in deze paragraaf, zie paragraaf 16. Voor de volledige tekst van de Nota's die worden genoemd in deze rubriek, zie rubriek 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In de frisse lucht brengen. Indien symptomen aanhouden, een arts raadplegen.

Skin contact

Onmiddellijk met veel water afwassen gedurende tenminste 15 minuten.

Eye contact

Onmiddellijk met veel water spoelen gedurende tenminste 15 minuten. Indien oogirritatie aanhoudt een specialist raadplegen.

Ingestion

Mond spoelen met water. Indien symptomen aanhouden, een arts raadplegen.

Immediate Medical Attention

Indien symptomen aanhouden, een arts raadplegen.

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Kooldioxide (CO2), Droogpoeder, Waternevel, Alcoholbestendig schuim

Unsuitable media

Sterke waterstraal

Specific hazards

Bij verhitting of bij brand kunnen giftige gassen worden gevormd.

Firefighter Protection

Bij brand een persluchtmasker dragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet naar het oppervlaktewater of de riolering laten afvloeien. Vermijd indringen in de bodem.

Cleanup methods

opnemen met een vonkvrije stofzuiger of door dweilen en overbrengen in een vat voor verwerking volgens plaatselijke voorschriften (zie sectie 13).

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Aanraking met de ogen en de huid vermijden.

Storage

Opslaan bij kamertemperatuur in de originele container. Op een koele en goed geventileerde plaats bewaren. Beschermen tegen vorst.

Hygiene

Zorg voor oogdouches of oogspoelvloeistof op de arbeidsplaats.

Fire prevention

Gebruik blusmiddelen die geschikt zijn voor de plaatselijke omstandigheden en de omgeving.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Zorg voor voldoende luchtverversing en/of afzuiging op de werkplaats.

Hands

Neopreen. Beschermhandschoenen volgens EN 374. De feitelijke doordrenkingstijd kan worden verkregen bij de fabrikant van de beschermhandschoenen en moet in acht worden genomen. Handschoenen moeten weggegooid en vervangen worden bij tekenen van degradatie of chemische doorbraak.

Eyes

Bescherming van de ogen (EN 166). Veiligheidsbril.

Respiratory

niet nodig bij normaal gebruik

Skin/Body

Chemicaliënbestendige kledij conform DIN EN 13034 (Type 6).

Environmental

Niet naar het oppervlaktewater of de riolering laten afvloeien. Vermijd indringen in de bodem.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
kenmerkend
Flash Point
> 200 °C
Solubility In Water
niet mengbaar
Ph
---
Boiling Point
> 200 °C
Vapor Density
---
Properties Status
---
Physical State
vloeibaar
Physical State Data
liquid
Softening Point
---
State Under Standard Conditions
---
Solubility In Fat
---
Form
---
Evaporation Rate
---
Crystallisation Point
---
Molecular Weight
---
Relative Evaporation Rate
---
Melting Point
Niet van toepassing
Decomposition Temperature
---
Relative Density
---
Cloud Point
---
Freezing Point
---
Metal Corrosion
---
Odor Threshold
---
Bulk Density
---
Solidification Point
---
Voc Content
---
Explosive Limits
---
Lower Explosive Limit
---
Kinematic Viscosity
---
Partition Coefficient
---
Dynamic Viscosity
circa250 mPas
Flammability
---
Colour Intensity
---
Density
0,82 - 0,86 g/cm³
Colour
beige
Vapor Pressure
Geen gegevens beschikbaar
Auto Ignition Temperature
niet zelfontvlambaar
Upper Explosive Limit
---
Solubility
---
Appearance
vloeibaar
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder de aanbevolen opslagomstandigheden.

Reactivity

Geen specifieke gevaren te noemen.

Hazardous reactions

Niets bekend.

Avoid

Niet oververhitten om thermische ontleding te voorkomen.

Incompatible

Sterke oxidatiemiddelen

Decomposition

Geen ontleding indien aanwijzingen worden gevolgd. Thermische ontleding : > 200 °C

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Verwijderen volgens plaatselijke voorschriften. Voor advies contact opnemen met Chemetall BV Afdeling Services (+31 412 681 891).

Waste Codes

national code
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Het product is geclassificeerd en geëtiketteerd volgens EG-richtlijnen of de respectievelijke landelijke wetgeving. Plaatselijke of landelijke implementaties van GHS implementeren mogelijk niet alle gevarenklassen en -categorieën.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GARDOBOND ADDITIVE H 7430?

The signal word is no signal word.

What is the physical form of GARDOBOND ADDITIVE H 7430?

GARDOBOND ADDITIVE H 7430 is a vloeibaar appearing as vloeibaar with beige color. It has kenmerkend odor.

What is GARDOBOND ADDITIVE H 7430 used for?

Antischuimmiddel

What is the melting point of GARDOBOND ADDITIVE H 7430?

The melting point is Niet van toepassing and the boiling point is > 200 °C.

Compliance Scanner

Scan your compliance