NextSDS Logo
Safety Data Sheet NL

GRAFLOSCON C-SG 0 ULTRA

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GRAFLOSCON C-SG 0 ULTRA
Product Code
039067

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

K

Klüber Lubrication München KG

manufacturer

Geisenhausenerstr. 7, D 81379 München

++49 - 89 - 7876 - 0

K

KLÜBER LUBRICATION BENELUX SA/NV

distributor

Rue Cardinal Mercier 100, B-7711 DUYTRENDES

++32/(0)56 48 33 11

Emergency Contacts

Klüber Lubrication München KG

++49 - 89 - 7876 - 0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

minerale olie, aluminium-zeep, grafiet

Chemical Name CAS Number Concentration Hazardous
minerale olie --- --- No
aluminium-zeep --- --- No
grafiet --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Niet van toepassing

Skin contact

Met zeep en overvloedig water afwassen.

Eye contact

Met overvloedig water spoelen.

Ingestion

Geen braken opwekken.

Immediate Medical Attention

Medische verzorging is vereist.

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

verneveld water, schuim, poeder, kooldioxide (CO2)

Unsuitable media

sterke waterstraal

Specific hazards

Bij brand kan vrijgesteld worden: Koolmonoxide, koolwaterstoffen

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet naar het oppervlaktewater of de riolering laten afvloeien

Cleanup methods

Mechanische apparatuur gebruiken.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geen speciale gebruiksaanwijzingen vereist

Storage

Opslaan bij kamertemperatuur in de originele verpakking.

Fire prevention

Geen speciale voorzorgsmaatregelen vereist.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

niet van toepassing

Hands

Geen speciale beschermingsmiddelen nodig.

Eyes

Geen speciale beschermingsmiddelen nodig.

Respiratory

Geen speciale beschermingsmiddelen nodig.

Skin/Body

Geen speciale beschermingsmiddelen nodig.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
---
Explosive Limits
---
Melting Point
---
Decomposition Temperature
---
Metal Corrosion
---
Boiling Point
---
Colour
zwart
Upper Explosive Limit
niet van toepassing
Softening Point
---
Voc Content
---
Molecular Weight
---
Properties Status
---
Relative Evaporation Rate
---
Lower Explosive Limit
niet van toepassing
Vapor Pressure
niet van toepassing
Dynamic Viscosity
---
Freezing Point
---
Auto Ignition Temperature
niet van toepassing °C
Odor
kenmerkend
Density
ca. 0,96 g/cm³
Flammability
---
Partition Coefficient
---
Solubility In Fat
---
Appearance
---
Evaporation Rate
---
Physical State
pasta
Kinematic Viscosity
niet van toepassing
Bulk Density
---
Solubility
---
Solubility In Water
onoplosbaar
Vapor Density
---
Form
pasta
Ph
niet van toepassing
Cloud Point
---
Physical State Data
liquid
Crystallisation Point
---
Relative Density
---
Colour Intensity
---
Flash Point
niet van toepassing
Solidification Point
---
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

Geen

Incompatible

sterke oxidatiemiddelen

Decomposition

geen bij normaal gebruik

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Kan verbrand worden, onder controle van de voorschriften van de lokale autoriteiten.

Disposal

De toekenning van de afvalcode dient overeenkomstig de richtlijn 75/442/EEG, sector- en processspecifiek, te gebeuren.

Waste Codes

120112 Afval van de machinale bewerking en oppervlaktebehandeling van metalen en kunststoffen; afval van machinale bewerking (smeden, lassen, persen, trekken, draaien, boren, snijden en vijlen); afgewerkte wassen en vetten EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Etiketteren is niet nodig volgens EG-richtlijnen.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GRAFLOSCON C-SG 0 ULTRA?

The signal word is no signal word.

What is the physical form of GRAFLOSCON C-SG 0 ULTRA?

GRAFLOSCON C-SG 0 ULTRA is a pasta with zwart color. It has kenmerkend odor.