NextSDS Logo
Safety Data Sheet NL

BUTYLGLYCOL

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BUTYLGLYCOL
Product Code
442021002

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Oplosmiddel

Manufacturers & Suppliers

C

Caldic Belgium n.v.

manufacturer

Terlochtweg 1, B-2620 Hemiksem-Belgium

+32 3 8704811

Emergency Contacts

Info centre of dangerous goods (BIG)

+32(0)14.58.45.45

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Xn Schadelijk

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
2-butoxyethanol EC: 203-905-0 111-76-2 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht toedienen, eventueel beademing, warmte. Wanneer de klachten niet ophouden, een arts raadplegen.

Skin contact

Met water en zure zeep wassen. Wanneer de huid geïrriteerd blijft, een dokter raadplegen.

Eye contact

Ogen met open ooglid een aantal minuten onder stromend water afspoelen en dokter raadplegen.

Ingestion

Mond spoelen en overvloedig water drinken. Geen braken teweegbrengen en onmiddellijk medische hulp.

Immediate Medical Attention

onmiddellijk medische hulp

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcoholbestendig schuim, Waternevel, Bluspoeder, Kooldioxyde

Unsuitable media

Krachtige waterstraal

Specific hazards

Koolmonoxyde (CO)

Instructions

De aan gevaar blootgestelde tanks met watersproeistraal koelen.

Firefighter Protection

Adembeschermingsapparaat dragen dat niet afhankelijk is van de omgevingslucht.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Cleanup methods

Met vloeistofbindend materiaal opnemen.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

Storage

Op een koele plaats bewaren.

Fire prevention

Maatregelen treffen tegen ontlading van statische elektriciteit. Onstekingsbronnen op afstand houden - niet roken.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Geen aanvullende gegevens. Zie 7.

Hands

Handschoenmateriaal: Butylrubber, Fluorrubber (Viton). Aanbevolen materiaaldikte: ≥ 0.5 mm. Doordringingstijd: >480 minuten (permeatie volgens EN 374 Deel 3: Level 6). Niet geschikt: Natuurrubber (latex), Handschoenen uit PVC, Nitrielrubber, Chloropreenrubber.

Eyes

Veiligheidsbril

Respiratory

Bij onvoldoende ventilatie ademhalingsbescherming.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
---
Evaporation Rate
---
Appearance
Olieachtig
Physical State Data
liquid
Vapor Density
4.1 g/cm3
Flash Point
67°C
Melting Point
-70.4°C
Solidification Point
---
Partition Coefficient
0.8 log POW
Metal Corrosion
---
Molecular Weight
---
Vapor Pressure
0.8 hPa
Solubility In Fat
---
Density
0.9 g/cm³
Colour Intensity
---
State Under Standard Conditions
---
Properties Status
---
Relative Evaporation Rate
---
Crystallisation Point
---
Physical State
Olieachtig
Explosive Limits
---
Cloud Point
---
Ph
---
Solubility In Water
Volledig mengbaar.
Relative Density
---
Kinematic Viscosity
---
Dynamic Viscosity
3.3 mPas
Upper Explosive Limit
10.6 Vol %
Freezing Point
---
Form
Olieachtig
Voc Content
---
Colour
Kleurloos
Bulk Density
---
Auto Ignition Temperature
240°C
Softening Point
---
Solubility
---
Flammability
---
Boiling Point
168-173°C
Lower Explosive Limit
1.1 Vol %
Decomposition Temperature
---
Odor
Karakteristiek
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen afbraak bij gebruik volgens voorschrift.

Hazardous reactions

Reacties met sterke oxydatiemiddelen. Reacties met zuren. Reacties met sterke alkaliën. Reacties met lichtmetalen onder vorming van waterstof. Peroxydevorming mogelijk.

Avoid

Geen afbraak bij gebruik volgens voorschrift.

Incompatible

sterke oxydatiemiddelen, zuren, sterke alkaliën, lichtmetalen

Decomposition

Koolmonoxyde en kooldioxyde

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Het product is volgens de EG-richtlijnen/GefStoffV (de verordening inzake gevaarlijke stoffen) geclassificeerd en gekenmerkt.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BUTYLGLYCOL?

The signal word is na: r-phrases.

What is the physical form of BUTYLGLYCOL?

BUTYLGLYCOL is a olieachtig appearing as olieachtig with kleurloos color. It has karakteristiek odor.

What is BUTYLGLYCOL used for?

Oplosmiddel

What is the melting point of BUTYLGLYCOL?

The melting point is -70.4°C and the boiling point is 168-173°C.