NextSDS Logo
Xy

Xyleen pro analyse ACS, ISO, Reag. Ph Eur

NA: R-PHRASES vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Xyleen pro analyse ACS, ISO, Reag. Ph Eur
Product Code
108681

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagens voor analyse Chemische productie Farmaceutische productie en analyse

Overview

Xyleen pro analyse ACS, ISO, Reag. Ph Eur commonly used reagens voor analyse chemische productie farmaceutische productie en analyse.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

na: r-phrases

Hazard Classifications

Ontvlambaar
Acute Tox.
Acute Tox.
Skin Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA

manufacturer

64271 Darmstadt * Duitsland

DE

+49 6151 72-2440

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Merck KGaA

+49 6151 722440

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Dimethylbenzenes
EC: 215-535-7
1330-20-7 Not specified Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

frisse lucht. Bij ademlistland: mond-op-mond-beademing of mechanische beademing. Indien nodig zuurstofmasker.

Skin Contact

met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.

Eye Contact

geopende oogleden uitspoelen met ruim voldoende water.

Ingestion/Swallowing

voorzichtig bij braken. Luchtwegen vrijhouden. Toedienen: actieve kool (norit) (20-40 g in 10 % suspensie).

Symptoms:

Gevaar voor aspiratie!

Immediate Medical Attention Required

Direct arts waarschuwen. Indien nodig oogarts raadplegen. Meteen arts waarschuwen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
vloeibaar
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
kleurloos
Colour Intensity
Not available
Form
Not available
Odor
aromatisch
Odor Threshold
Not available
Ph
niet van toepassing
Melting Point
> -34 °C
Critical Property
Boiling Point
137-143 °C
Critical Property
Flash Point
25 °C c.c.
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
(20 °C) 10 hPa
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
(20 °C) 0.86 g/cm³
Critical Property
Flammability
Not available
Upper Explosive Limit
7.0 Vol%
Lower Explosive Limit
1.0 Vol%
Explosive Limits
Not available
Auto Ignition Temperature
~ 465 °C (DIN 51794)
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
3.12
Solubility In Water
(20 °C) 0.2 g/l
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
(20 °C) ~ 0.6 mPa*s
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Bij vol contact: Handschoen materiaal: Viton, Dikte van de laag: 0.70 mm, Doorbraaktijd: >480 Min. Bij sproei contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.40 mm, Doorbraaktijd: >30 Min. De te gebruiken beschermende handschoenen, moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 890 Vitoject (volledig contact), 730 Camatril -Velours (spat contact). De bovengenoemde doorbraak tijden, werden met materiaalproeven van de aanbevolen handschoenen door KCL in laboratoriummetingen vlgs. EN374 onderzocht. Deze aanbeveling heeft alleen betrekking op het in het veilgheidsinformatieblad genoemde product, dat door ons geleverd wordt voor de door ons aangegeven gebruiksdoeleinden. Wanneer het middel wordt opgelost in of vermengd met andere substanties en onder andere condities dan vermeld in EN374 neemt u dan svp contact op met de leverancier van de CE-goedgekeurde handschoenen (b.v. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eye Protection

Bescherming van de ogen benodigd

Respiratory Protection

Bescherming van de ademhalingswegen nodig indien dampen/aerosolen gevormd worden. Filter A (volgens DIN 3181) voor dampen van organische verbindingen.

Skin/Body Protection

Het soort lichaamsbescherming moet al naargelang van de concentratie en de hoeveelheid gevaarlijke stoffen op de werkplek gekozen worden. De chemische weerstand van de bescherming moet met de leverancier geregeld worden.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1307

Transport Hazard Class

3

Packing Group

III

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Xyleen pro analyse ACS, ISO, Reag. Ph Eur?

The signal word for this substance is "na: r-phrases".

What is the physical form of Xyleen pro analyse ACS, ISO, Reag. Ph Eur?

Xyleen pro analyse ACS, ISO, Reag. Ph Eur is a vloeibaar with kleurloos color. It has aromatisch odor.

What is Xyleen pro analyse ACS, ISO, Reag. Ph Eur used for?

Reagens voor analyse Chemische productie Farmaceutische productie en analyse

What is the melting point of Xyleen pro analyse ACS, ISO, Reag. Ph Eur?

The melting point is > -34 °C and the boiling point is 137-143 °C.