NextSDS Logo
Safety Data Sheet NL

Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR®

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR®
Product Code
170362

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagens voor analyse

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-2440

Emergency Contacts

Merck KGaA

+49 6151 722440

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Waterige zoutzuuroplossing.

Chemical Name CAS Number Concentration Hazardous
Zoutzuur EC: 231-595-7 7647-01-0 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

frisse lucht.

Skin contact

met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.

Eye contact

geopende oogelden uitspoelen met ruim voldoende water. Oogarts raadplegen.

Ingestion

onmiddellijk veel water drinken. Bij onwel bevinden arts raadplegen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Op de omgeving afstemmen.

Specific hazards

Niet brandbaar. Door brand in de omgeving is het ontstaan van gevaarlijke dampen mogelijk. In geval van brand mogelijk ontstaan van: chloorwaterstof.

Firefighter Protection

Blijf niet in de gevaarlijke zone zonder beademingsapparatuur die onafhankelijk is van de omgevingslucht. Om huidcontact te vermeiden, houd een veilige afstand en draag geschikte beschermende kleding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Adem geen dampen/aerosolen in. Vermijd contact met de stof.

Environmental

Niet in riolering laten geraken.

Cleanup methods

Met vloeistofabsorberend en neutraliserend matriaal, b.v. Chemizorb® H+ (Art.Nr. 101595) opnemen.

Materials: vloeistofabsorberend en neutraliserend matriaal, b.v. Chemizorb® H+ (Art.Nr. 101595)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geen nadere eisen.

Storage

Goed afgesloten. Bij +15°C tot +25°C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
---
Colour
kleurloos
Lower Explosive Limit
niet beschikbaar
Odor
geurloos
Evaporation Rate
---
Crystallisation Point
---
Partition Coefficient
---
Form
---
Density
~ 1.034 g/cm³ (20 °C)
State Under Standard Conditions
---
Dynamic Viscosity
---
Flash Point
niet beschikbaar
Relative Evaporation Rate
---
Decomposition Temperature
---
Relative Density
---
Odor Threshold
---
Physical State Data
liquid
Physical State
vloeibaar
Auto Ignition Temperature
niet beschikbaar
Bulk Density
---
Colour Intensity
---
Voc Content
---
Flammability
---
Solubility In Water
niet beschikbaar
Upper Explosive Limit
niet beschikbaar
Boiling Point
niet beschikbaar
Kinematic Viscosity
---
Properties Status
---
Vapor Density
---
Metal Corrosion
---
Melting Point
niet beschikbaar
Solubility
---
Explosive Limits
---
Appearance
kleurloos
Cloud Point
---
Softening Point
---
Molecular Weight
---
Ph
~ 0 (20 °C)
Solubility In Fat
---
Solidification Point
---
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

Verhitting.

Incompatible

metalen (vorming van waterstof), metalen, metaallegeringen.

Decomposition

bij brand: Zie hoofdstuk 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Voor HCl geldt in het algemeen het volgende: Schadelijk effect voor waterorganismen. Schadelijke werking door pH-verschuiving. Biologische effecten: zoutzuur (en door reactie ontstane zoutzuur): dodelijk vanaf 25 mg/l voor vissen; Leuciscus idus LC50: 862 mg/l (1N oplossing). Schadelijke effecten treden op: planten 6 mg/l. Veroorzaakt geen biologisch zuurstof tekort.

Schadelijk effect voor waterorganismen door pH-verschuiving. Geen biologisch zuurstoftekort.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Chemicaliën moeten met inachtneming van de desbetreffende nationale voorschriften afgevoerd worden.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1789
Shipping Name
HYDROCHLORIC ACID
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Etikettering volgens EG richtlijnen

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR®?

The signal word is no signal word.

What is the physical form of Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR®?

Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR® is a vloeibaar appearing as kleurloos with kleurloos color. It has geurloos odor.

What is Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR® used for?

Reagens voor analyse

What is the melting point of Tin ICP standaard herleidbaar naar SRM van NIST SnCl4 in HCl 7% 1000 mg/l Sn CertiPUR®?

The melting point is niet beschikbaar and the boiling point is niet beschikbaar.