NextSDS Logo
GR

GRIFFON TRACEE-LAC AER 300ML*12 NLFR

DANGER Arosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GRIFFON TRACEE-LAC AER 300ML*12 NLFR

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Metaalbewerkingsmiddel
Uses Advised Against
Geen verdere relevante informatie verkrijgbaar.

Overview

GRIFFON TRACEE-LAC AER 300ML*12 NLFR commonly used metaalbewerkingsmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P261: Inademing van spuitnevel vermijden.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 /122 F.
  • P501: De inhoud/verpakking afvoeren overeenkomstig de nationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

NL

+31 88 3235700

+31 88 3235800

Bison International

manufacturer

Excelsiorlaan 27, B 3 B-1930 Zaventem

BE

+32 3 710 92 92

+32 3 710 92 90

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

070 245245

BE

Groothertogdom Luxemburg

8002 - 5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mengsels

General Composition

Metaalbewerkingsmiddel

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
METHYLETHYLCETONE
EC: 201-159-0
78-93-3 25-50% Hazardous
butane substance with national workplace exposure limit(s) (AT, BE, BG, DE, DK, ET, FI, FR, GB, GR, HU, IE, IT, LV. PL, PT)
EC: 203-448-7
106-97-8 25-50% Hazardous
opaan
EC: 200-827-9
74-98-6 2.5-10% Hazardous
Isobutan, rein
EC: 200-857-2
75-28-5 1-2.5% Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden. Geen speciale maatregelen noodzakelijk.

Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Arosol
Critical Property
Physical State Data
aerosol
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Volgens de productbeschrijving
Colour Intensity
Not available
Form
Arosol
Odor
Karakteristiek
Odor Threshold
Niet bepaald.
Ph
Niet bepaald.
Melting Point
Niet bepaald.
Critical Property
Boiling Point
79-80,5 C
Critical Property
Flash Point
-97 C
Critical Property
Freezing Point
Niet bepaald.
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Niet bruikbaar.
Vapor Pressure
2100 hPa
Vapor Density
Niet bepaald.
Relative Density
Niet bepaald.
Bulk Density
Not available
Density
0,712 g/cm
Critical Property
Flammability
Niet bruikbaar.
Upper Explosive Limit
11,5 Vol %
Lower Explosive Limit
1,5 Vol %
Explosive Limits
Not available
Auto Ignition Temperature
365 C
Decomposition Temperature
Niet bepaald.
Solubility
Niet resp. gering mengbaar.
Partition Coefficient
Niet bepaald.
Solubility In Water
Niet resp. gering mengbaar.
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Niet bepaald.
Kinematic Viscosity
Niet bepaald.
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Handschoenmateriaal Butylrubber. Aanbevolen materiaaldikte : > 0,7 mm. Voor het mengsel van de hieronder vermelde chemicalin moet de penetratietijd minstens 120 minuten bedragen (permeatie volgens EN 374 Deel 3: Level 4).

Eye Protection

Nauw aansluitende veiligheidsbril

Respiratory Protection

Bij onvoldoende ventilatie ademhalingsbescherming. Aanbevolen filter voor kortstondig gebruik: Filter A

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1950

Packing Group

Niet van toepassing

IMDG Maritime Transport Precautions

SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living SG69 For AEROSOLS with a maximum capacity quarters. of 1 litre: Segregation as for class 9. Stow "separated from" class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GRIFFON TRACEE-LAC AER 300ML*12 NLFR?

The signal word for this substance is "danger".

What is the physical form of GRIFFON TRACEE-LAC AER 300ML*12 NLFR?

GRIFFON TRACEE-LAC AER 300ML*12 NLFR is a arosol with volgens de productbeschrijving color. It has karakteristiek odor.

What is the solubility of GRIFFON TRACEE-LAC AER 300ML*12 NLFR?

Niet resp. gering mengbaar.

What is GRIFFON TRACEE-LAC AER 300ML*12 NLFR used for?

Metaalbewerkingsmiddel

What are the hazard statements for GRIFFON TRACEE-LAC AER 300ML*12 NLFR?

This substance has 3 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken.

What is the melting point of GRIFFON TRACEE-LAC AER 300ML*12 NLFR?

The melting point is Niet bepaald. and the boiling point is 79-80,5 C.