NextSDS Logo
Safety Data Sheet NL

BYK-028

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BYK-028

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Defoamer

Manufacturers & Suppliers

B

BYK-Chemie GmbH

manufacturer

Abelstrasse 45, 46483 Wesel

+49 281 670-0

Emergency Contacts

Emergency Contact

+31 10 713 8195

NL, EN

Emergency Contact

+44 1235 239670

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 (0)88 755 8000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Compound of modified polysiloxanes, polyether and hydrophobic particles

Notes

Geen gevaarlijke ingrediënten

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bij bewusteloosheid stabiele zijligging toepassen en medische hulp inroepen. Indien symptomen aanhouden, een arts raadplegen.

Eye contact

Contactlenzen uitnemen. Onbeschadigd oog beschermen. Indien oogirritatie aanhoudt een specialist raadplegen.

Ingestion

Ademhalingswegen vrijhouden. Geen melk of alcoholische dranken geven. Nooit een bewusteloos persoon laten drinken (of eten). Indien symptomen aanhouden, een arts raadplegen.

Medical Treatment

Geen gegevens beschikbaar.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Schuim, Kooldioxide (CO2), Droogpoeder, watersproeistraal

Unsuitable media

Sterke waterstraal

Instructions

Gebruik blusmiddelen die geschikt zijn voor de plaatselijke omstandigheden en de omgeving.

Firefighter Protection

Draag indien nodig een persluchtmasker bij brandbestrijding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Persoonlijke beschermingsmiddelen gebruiken.

Environmental

Niet naar het oppervlaktewater of de riolering laten afvloeien.

Cleanup methods

Opnemen met absorberend materiaal (bv. doek, vlies). In geschikte en gesloten containers bewaren voor verwijdering.

Materials: absorberend materiaal (bv. doek, vlies)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Voor persoonlijke bescherming zie paragraaf 8. Niet roken, eten en drinken op de werkplek.

Storage

Elektrische installaties/werkmaterialen moeten voldoen aan de technische veiligheidsnormen. Geen ontleding indien bewaard en toegepast zoals aangegeven.

Hygiene

Algemene industriële hygiëne toepassen.

Fire prevention

Normale maatregelen voor preventieve brandbeveiliging.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Materiaal: Nitrilrubber, Doorbraaktijd: > 480 min, Handschoendikte: 0,4 mm

Eyes

beschermbril

Respiratory

Geen persoonlijke adembescherming vereist bij normaal gebruik.

Skin/Body

Beschermingskleding

Environmental

Niet naar het oppervlaktewater of de riolering laten afvloeien.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Odor
licht
Solubility In Fat
---
Physical State
vloeibaar
Flammability
---
Bulk Density
---
Kinematic Viscosity
---
Solidification Point
---
State Under Standard Conditions
---
Solubility In Water
emulgeerbaar
Relative Density
Geen gegevens beschikbaar
Explosive Limits
---
Density
1,0450 g/cm3 (20,00 °C, 1.013,000000 hPa)
Cloud Point
---
Ph
7, Concentratie: 10 % (20 °C)
Dynamic Viscosity
circa 2.660 mPa.s (20 °C)
Molecular Weight
---
Crystallisation Point
---
Evaporation Rate
Geen gegevens beschikbaar
Physical State Data
liquid
Decomposition Temperature
Geen gegevens beschikbaar
Partition Coefficient
Geen gegevens beschikbaar
Softening Point
---
Upper Explosive Limit
Geen gegevens beschikbaar
Vapor Density
---
Freezing Point
< -30 °C
Properties Status
---
Boiling Point
> 250 °C
Melting Point
---
Odor Threshold
Geen gegevens beschikbaar
Voc Content
---
Flash Point
169 °C
Form
---
Appearance
gray - light yellow, troebel
Colour
gray - light yellow
Auto Ignition Temperature
> 200,00 °C
Lower Explosive Limit
Geen gegevens beschikbaar
Vapor Pressure
< 0,1000000 hPa (20,00 °C)
Solubility
emulgeerbaar
Colour Intensity
---
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen ontleding indien bewaard en toegepast zoals aangegeven.

Reactivity

Geen ontleding indien bewaard en toegepast zoals aangegeven.

Hazardous reactions

Stabiel onder de aanbevolen opslagomstandigheden. Geen specifieke gevaren te noemen.

Avoid

Geen gegevens beschikbaar

Incompatible

Sterke oxidatiemiddelen

Decomposition

Geen ontleding indien bewaard en toegepast zoals aangegeven.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BYK-028?

The signal word is no signal word.

What is the physical form of BYK-028?

BYK-028 is a vloeibaar appearing as gray - light yellow, troebel with gray - light yellow color. It has licht odor.

What is the solubility of BYK-028?

emulgeerbaar

What is BYK-028 used for?

Defoamer