NextSDS Logo
Bi

Biomix ATM

NO SIGNAL WORD Vloeistof SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Biomix ATM
Product Code
BIO 5

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reinigingsmiddel

Overview

Biomix ATM is a vloeistof, groen substance commonly used reinigingsmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P102: Buiten het bereik van kinderen houden.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

NV Bionova company logo - Safety Data Sheet supplier organization

NV Bionova

manufacturer

Evangeliestraat 66A 9220 Hamme Belgium

BE

0032 35 55 43 93

0032 52 55 47 21

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Bionova NV

+32(0) 52 55 43 93

BE

During normal opening times

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
dipropyleenglycolmonomethylether
EC: 252-104-2
34590-94-8 1-5% Hazardous
niet-ionogene oppervlakteactieve stoffen N/A 5% Non-hazardous
amfotere oppervlakteactieve stoffen N/A 5% Non-hazardous
enzymen N/A Not specified Non-hazardous

Additional Information

Verordening (EG) Nr. 648/2004 betreffende detergentia / Etikettering van gehalten

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden.

Eye Contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen

Ingestion/Swallowing

Als de klachten niet minderen, een arts raadplegen

Immediate Medical Attention Required

Geen verdere relevante informatie verkrijgbaar.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State Data
liquid
Flash Point
Niet bruikbaar.
Critical Property
Appearance
Vloeistof, Groen
Solidification Point
Not available
Solubility In Fat
Not available
State Under Standard Conditions
Not available
Bulk Density
Not available
Decomposition Temperature
Niet bepaald.
Colour Intensity
Not available
Upper Explosive Limit
Niet bepaald.
Boiling Point
100 C
Critical Property
Cloud Point
Not available
Odor Threshold
Niet bepaald.
Melting Point
Niet bepaald.
Critical Property
Explosive Limits
Not available
Voc Content
Not available
Lower Explosive Limit
Niet bepaald.
Metal Corrosion
Not available
Vapor Pressure
Niet bepaald.
Odor
Karakteristiek
Freezing Point
Not available
Auto Ignition Temperature
Het produkt ontbrandt niet uit zichzelf.
Vapor Density
Niet bepaald.
Dynamic Viscosity
Niet bepaald.
Physical State
Vloeistof
Critical Property
Solubility In Water
Volledig mengbaar.
Colour
Groen
Flammability
Niet bruikbaar.
Form
Vloeistof
Relative Evaporation Rate
Not available
Relative Density
Niet bepaald.
Properties Status
Not available
Softening Point
Not available
Ph
10,5 (dilution 10 %) bij 20 C
Molecular Weight
Not available
Kinematic Viscosity
Niet bepaald.
Crystallisation Point
Not available
Partition Coefficient
Niet bepaald.
Evaporation Rate
Niet bepaald.
Solubility
Not available
Density
1,02 g/cm bij 20 C
Critical Property
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Op grond van falende testen kan geen aanbeveling voor handschoenmateriaal voor het product / de bereiding / het chemicalinmengsel afgegeven worden. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vr het gebruik worden getest. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.

Eye Protection

Bij het omgieten is het gebruik van een veiligheidsbril aan te bevelen.

Respiratory Protection

Niet noodzakelijk.

Skin/Body Protection

Draag geschikte beschermende kleding

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Biomix ATM?

The signal word for this substance is "no signal word".

What is the physical form of Biomix ATM?

Biomix ATM is a vloeistof appearing as vloeistof, groen with groen color. It has karakteristiek odor.

What is Biomix ATM used for?

Reinigingsmiddel

What is the melting point of Biomix ATM?