NextSDS Logo
Le

Leak Detection Spray 500ml

WARNING vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Leak Detection Spray 500ml

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
/️
Uses Advised Against
/️

Overview

Leak Detection Spray 500ml is a kleurloos substance commonly used /️.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Waarschuwing)

Hazard Classifications

H229

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H229: Houder onder druk: kan openbarsten bij verhitting

Precautionary Statements

  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50°C/122°F.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Xeon International company logo - Safety Data Sheet supplier organization

Xeon International

manufacturer

Industrielaan 18 8770 Ingelmunster

BE

051336050

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Distikstofmonoxide
EC: 233-032-0
10024-97-2 3% Hazardous
Natriumnitriet
EC: 231-555-9
7632-00-0 1% Hazardous

Composition Notes

Voor de volledige tekst van de H-zinnen die worden genoemd in deze rubriek, zie rubriek 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Rechtop laten zitten, frisse lucht, rust en naar ziekenhuis vervoeren.

Symptoms:

geen

Skin Contact

Verontreinigde kleding uittrekken, eerst spoelen met veel water, dan zonodig naar arts vervoeren.

Symptoms:

geen

Eye Contact

Eerst langdurig spoelen met water (contactlenzen verwijderen mits makkelijk mogelijk), dan naar arts brengen.

Symptoms:

roodheid

Ingestion/Swallowing

Mond laten spoelen, GEEN braken opwekken en onmiddellijk naar ziekenhuis vervoeren.

Symptoms:

diarree, hoofdpijn, buikkrampen, slaperigheid, braken

Immediate Medical Attention Required

Steeds zo spoedig mogelijk medisch advies inwinnen in geval van ernstige of aanhoudende stoornissen. Na oogcontact naar arts brengen. Na inslikken onmiddellijk naar ziekenhuis vervoeren. Na inademing naar ziekenhuis vervoeren.

Medical Treatment

geen

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

verneveld water, poeder, schuim, CO2

Unsuitable Extinguishing Media

geen

Specific Fire Hazards

geen

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Niet in de gemorste stoffen lopen of ze aanraken. Vermijden om de uitwasemingen, de rook, het stof en de damp in te ademen door boven de wind te blijven. Elk bezoedeld kledingstuk en elke bezoedelde beschermingsuitrusting na gebruik uittrekken en er zich op een veilige manier van ontdoen.

Environmental Precautions

Niet in riolering of openbare wateren laten wegstromen.

Cleanup Methods

Gemorst product zorgvuldig verzamelen en opslaan in geschikte houders. Eventueel laten opzuigen door absorberend materiaal.

Cleanup Materials:

absorberend materiaal

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
vloeibaar
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
kleurloos
Colour
kleurloos
Colour Intensity
Not available
Form
Not available
Odor
kenmerkend
Odor Threshold
Not available
Ph
Not available
Melting Point
0 °C
Critical Property
Boiling Point
100 °C
Critical Property
Flash Point
Not available
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
0,300
Evaporation Rate
0,300
Vapor Pressure
2.332 Pa
Vapor Density
Technisch onmogelijk
Relative Density
1,0010 kg/l
Bulk Density
Not available
Density
Not available
Flammability
Technisch onmogelijk
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
Not available
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Technisch onmogelijk
Solubility In Water
niet oplosbaar
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
0,000 g/l
Metal Corrosion
Not available
Dynamic Viscosity
1 mPa.s
Kinematic Viscosity
1 mm²/s
Properties Status
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Voorzichtig behandelen om lekkages te vermijden.

Storage Conditions

Bewaren in goed gesloten verpakking in een gesloten, vorstvrije, geventileerde ruimte.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Het beschermingsniveau en soorten van maatregelen zijn afhankelijk van de omstandigheden op de werkplek. Er moet voor adequate ventilatie gezorgd worden zodat de blootstellingslimieten niet overschreden worden. Voor meer informatie, zie rubriek 7.

Hand Protection

Met Viton-handschoenen (EN 374) hanteren. Minimale doorbraaktijd van > 480 minuten, dikte 0,70mm. Handschoenen voor gebruik goed controleren. Handschoenen netjes uittrekken zonder de buitenkant aan te raken met de blote hand. De geschiktheid voor een specifeke werkplek moet worden overlegd met de fabrikant van de beschermhandschoenen.

Eye Protection

Gebruik een nauw aansluitende veiligheidsbril (EN 166). Een volgelaatsscherm en beschermend pak dragen bij uitzonderlijke verwerkingsproblemen.

Respiratory Protection

Ademhalingsbescherming niet nodig. Bij hinderlijke blootstelling gebruik type ABEK gasmaskers. Eventueel gebruiken met voldoende afzuigventilatie.

Skin/Body Protection

Gebruik niet doorlaatbare beschermende kleding die bestand is tegen dit product. De keuze van specifeke onderdelen zoals gelaatsmasker, handschoenen, laarzen, schort of volledig pak hangt af van de werkzaamheden.

Environmental Exposure Controls

Voldoe aan de relevante milieureglementeringen die het lozen in lucht, water en grond beperken. Bescherm het milieu door juiste controlemaatregelen toe te passen om uitstoot te voorkomen of te beperken. Voor meer informatie, zie rubrieken 6 en 13.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Extreem hoge of lage temperaturen vermijden.

Reactivity

Stabiel onder normale omstandigheden.

Hazardous Reactions

geen

Conditions to Avoid

Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50C

Incompatible Materials

Verwijderd houden van ontstekingsbronnen.

Hazardous Decomposition Products

Onder de aanbevolen gebruiksomstandigheden worden geen gevaarlijke ontledingsproducten verwacht.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Het product mag geloosd worden in de aangegeven gebruiksconcentraties vermeld in rubriek 1.2, indien nodig, na neutralisatie tot pH 7.

Product Disposal Recommendations

Het product mag geloosd worden in de aangegeven gebruiksconcentraties vermeld in rubriek 1.2, indien nodig, na neutralisatie tot pH 7.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1950

Proper Shipping Name

UN 1950 Spuitbussen (aërosolen), verstikkend, 5A, (E)

Transport Hazard Class

5A

Packing Group

niet van toepassing

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Leak Detection Spray 500ml?

The signal word for this substance is "warning".

What is the physical form of Leak Detection Spray 500ml?

Leak Detection Spray 500ml is a vloeibaar appearing as kleurloos with kleurloos color. It has kenmerkend odor.

What is Leak Detection Spray 500ml used for?

/️

What are the hazard statements for Leak Detection Spray 500ml?

This substance has 1 hazard statements: H229: Houder onder druk: kan openbarsten bij verhitting

What is the melting point of Leak Detection Spray 500ml?

The melting point is 0 °C and the boiling point is 100 °C.