NextSDS Logo
So

Soudaseal 250XF

NO SIGNAL WORD Vast SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Soudaseal 250XF
Product Form
Mengsel

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Afdichtingsmiddelen, Consumentengebruik, Professioneel gebruik

Overview

Soudaseal 250XF is a vaste stof. substance commonly used afdichtingsmiddelen, consumentengebruik, professioneel gebruik.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Soudal N.V. company logo - Safety Data Sheet supplier organization

Soudal N.V.

undefined

Everdongenlaan 18-20 2300 Turnhout Belgium

BE

+32 14 42 42 31

+32 14 42 65 14

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Militaire Reine Astrid

+32 70 245 245

BE

24/7

Alle dringende vragen over vergiftigingen: 070 245 245 (gratis, 24/7)

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Militaire Reine Astrid

02 264 96 30

BE

indien onbereikbaar tel. 02 264 96 30 (normaal tarief)

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
destillaten (aardolie), met waterstof behandelde lichte paraffinische
EC: 265-158-7
64742-55-8 1-5% Hazardous
trimethoxyvinylsilaan
EC: 220-449-8
2768-02-7 1% Hazardous
reactiemassa van N, N’-ethaan-1,2-diylbis(hexaanamide) en 12-hydroxy-N-[2-[(1-oxyhexyl)amino]ethyl]octadecaanamide en N, N’-ethaan-1,2-diylbis(12-hydroxyoctadecaanamide)
EC: 432-430-3
N/A 1-5% Hazardous
N-(3-(trimethoxysilyl)propyl)ethyleendiamine
EC: 217-164-6
1760-24-3 0.1-1% Hazardous
dioctylbis(pentaan-2,4-dionato-O,O')tin
EC: 483-270-6
54068-28-9 0.1-1% Hazardous

Composition Notes

Noot L: De geharmoniseerde indeling van de stof als kankerverwekkend is van toepassing, tenzij kan worden aangetoond dat zij minder dan 3 % dimethylsulfoxide-extract bevat, gemeten volgens IP 346 (Determination of polycyclic aromatics in unused lubricating base oils and asphaltene free petroleum fractions Dimethyl sulphoxide extraction refractive index method, Institute of Petroleum, Londen), in welk geval ook voor die gevarenklasse de stof overeenkomstig titel II van deze verordening wordt ingedeeld. Volledige tekst van H- en EUH-zinnen: zie sectie 16

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.

Skin Contact

De huid met overvloedig water wassen.

Symptoms:

Herhaalde blootstelling kan een droge of een gebarsten huid veroorzaken.

Eye Contact

Als voorzorgsmaatregel de ogen met water uitspoelen.

Ingestion/Swallowing

Bij onwel voelen een antigifcentrum of een arts raadplegen.

Medical Treatment

Symptomatische behandeling.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Verneveld water. Droog poeder. Schuim.

Firefighter Protection Equipment

Niet ingrijpen zonder geschikte veiligheidsmiddelen. Onafhankelijk werkend ademhalingsapparaat. Volledig beschermende kleding.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Verontreinigde omgeving ventileren.

Environmental Precautions

Voorkom lozing in het milieu.

Cleanup Methods

Het product mechanisch opruimen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

State Under Standard Conditions
Not available
Solubility In Fat
Not available
Odor Threshold
Niet beschikbaar
Evaporation Rate
Not available
Relative Evaporation Rate
Not available
Flash Point
Niet van toepassing
Critical Property
Vapor Density
Not available
Flammability
Niet brandbaar.
Physical State Data
solid
Vapor Pressure
Niet beschikbaar
Solubility In Water
Not available
Softening Point
Not available
Molecular Weight
Not available
Density
1,485 g/cm³ (20°C)
Critical Property
Cloud Point
Not available
Dynamic Viscosity
Not available
Metal Corrosion
Not available
Partition Coefficient
Niet beschikbaar
Crystallisation Point
Not available
Solubility
Niet beschikbaar
Properties Status
Not available
Solidification Point
Not available
Explosive Limits
Not available
Ph
Niet beschikbaar
Lower Explosive Limit
Niet van toepassing
Bulk Density
Not available
Voc Content
< 1 %
Boiling Point
Niet beschikbaar
Critical Property
Physical State
Vast
Critical Property
Auto Ignition Temperature
Niet van toepassing
Freezing Point
Niet van toepassing
Relative Density
Niet beschikbaar
Colour
Verschillende kleuren.
Melting Point
Niet beschikbaar
Critical Property
Form
Not available
Appearance
Vaste stof.
Kinematic Viscosity
Niet van toepassing
Colour Intensity
Not available
Odor
karakteristiek.
Upper Explosive Limit
Niet van toepassing
Decomposition Temperature
Niet beschikbaar
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Zorg voor een goede ventilatie van de werkplek.

Draag een persoonlijke beschermingsuitrusting.

Storage Conditions

Op een goed geventileerde plaats bewaren.

Koel bewaren.

General Hygiene Measures

Niet eten, drinken of roken tijdens het gebruik van dit product. Na hantering van dit product altijd handen wassen.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Zorg voor een goede ventilatie van de werkplek.

Hand Protection

Beschermende handschoenen

Eye Protection

Veiligheidsbril

Respiratory Protection

Bij ontoereikende ventilatie een geschikt ademhalingsapparaat gebruiken

Skin/Body Protection

Draag geschikte beschermende kleding

Environmental Exposure Controls

Voorkom lozing in het milieu.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stabiel onder normale omstandigheden.

Reactivity

Het product is onder normale gebruiks-, opslag- en transportcondities niet reactief.

Hazardous Reactions

Geen gevaarlijke reacties bekend onder normale gebruiksomstandigheden.

Conditions to Avoid

Geen onder aanbevolen opslag- en hanteringscondities (zie lid 7).

Incompatible Materials

Geen aanvullende informatie beschikbaar

Hazardous Decomposition Products

Onder normale opslag- en gebruiksvoorwaarden zullen er geen gevaarlijke ontledingsproducten ontstaan.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Inhoud/verpakking afvoeren conform de sorteerinstructies van een erkend inzamelbedrijf.

Product Disposal Recommendations

Inhoud/verpakking afvoeren conform de sorteerinstructies van een erkend inzamelbedrijf.

Waste Classification Codes

08 04 10 niet onder 08 04 09 vallend afval van lijm en kit EWC
15 01 02 kunststofverpakking EWC
Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

Niet van toepassing

Proper Shipping Name

Niet van toepassing

Transport Hazard Class

Niet van toepassing

Packing Group

Niet van toepassing

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Soudaseal 250XF?

The signal word for this substance is "no signal word".

What is the physical form of Soudaseal 250XF?

Soudaseal 250XF is a vast appearing as vaste stof. with verschillende kleuren. color. It has karakteristiek. odor.

What is the solubility of Soudaseal 250XF?

Niet beschikbaar

What is Soudaseal 250XF used for?

Afdichtingsmiddelen, Consumentengebruik, Professioneel gebruik

What is the melting point of Soudaseal 250XF?

The melting point is Niet beschikbaar and the boiling point is Niet beschikbaar.