PO

POWER SPRAY

DANGER Aërosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
POWER SPRAY
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
N4YU-WEND-F4DX-W1U5

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Kleefmiddel

Overview

POWER SPRAY is a arosol substance commonly used kleefmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aquatic Chronic Category 2 H411
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P210: Verwijderd houden van open vuur en hete oppervlakken. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P271: Alleen buiten of in een goed geventileerde ruimte gebruiken.
  • P273: Voorkom lozing in het milieu.
  • P304 + P340: NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P312: Bij onwel voelen een ANTIGIFCENTRUM/arts raadplegen.
  • P321: Specifieke behandeling vereist (zie op dit etiket).
  • P362 + P364: Verontreinigde kleding uittrekken en wassen alvorens deze opnieuw te gebruiken.
  • P405: Achter slot bewaren.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122 °F.
  • P501: De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

CAIROX BELGIUM company logo - Safety Data Sheet supplier organization

CAIROX BELGIUM

manufacturer

Hoogstraat 180, 1930 Zaventem, BELGIUM

BE

+32 (0)2 725 31 80

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NVIC-Nederland

+31 (0)88 755 8000

NL

(alleen voor artsen)

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van onderstaande stoffen met ongevaarlijke bijmengingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
dimethylether
EC: 204-065-8
115-10-6 50-80% Hazardous
nafta (aardolie), met waterstof behandeld licht (< 0.1% Benzeen CAS nr. 71-43-2)
EC: 265-151-9
64742-49-0 20-40% Hazardous
aceton
EC: 200-662-2
67-64-1 20-40% Hazardous
zinkbis(dibutyldithiocarbamaat)
EC: 205-232-8
136-23-2 0.5% Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Als het slachtoffer niet ademt: Voer mond-op-mond of mond-op-neus reanimatie uit, neem onmiddellijk contact op met noodarts

Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen. Onmiddellijk met water afwassen.

Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Ingestion/Swallowing

Mond spoelen met water. Als de klachten niet minderen, een arts raadplegen

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

CO2, bluspoeder of waterstraal. Grotere brand met waterstraal bestrijden of met schuim.

Unsuitable Extinguishing Media

Krachtige waterstraal

Specific Fire Hazards

Onder bepaalde brandomstandigheden mogen sporen van giftige stoffen niet worden uitgesloten

Firefighter Protection Equipment

Adembeschermingsapparaat dragen dat niet afhankelijk is van de omgevingslucht. Volledig beschermende overall aantrekken.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Beschermende kleding aantrekken. Niet beschermde personen op afstand houden.

Environmental Precautions

Mag niet in riolering of afvalwater terechtkomen. Bij indringen in afvalwater of riolering moet de bevoegde instantie gewaarschuwd worden. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Cleanup Methods

Besmet materiaal zoals afval volgens punt 13 verwijderen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Upper Explosive Limit
13 Vol %
Voc Content
Not available
Molecular Weight
Not available
Appearance
Arosol
Dynamic Viscosity
275 mPas
Form
Aërosol
State Under Standard Conditions
Not available
Solubility In Fat
Not available
Relative Evaporation Rate
Not available
Auto Ignition Temperature
370 °C
Solubility
Not available
Partition Coefficient
Niet bepaald.
Physical State Data
aerosol
Colour Intensity
Not available
Bulk Density
Not available
Softening Point
Not available
Flammability
Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
Ph
Niet bruikbaar
Solidification Point
Not available
Crystallisation Point
Not available
Boiling Point
55,8-56,6 °C
Critical Property
Flash Point
<-30 °C
Critical Property
Explosive Limits
Not available
Metal Corrosion
vervalt
Odor Threshold
Niet bepaald.
Physical State
Aërosol
Critical Property
Properties Status
Not available
Decomposition Temperature
Niet bepaald.
Odor
Oplosmiddelachtig
Cloud Point
Not available
Evaporation Rate
Niet bepaald.
Vapor Density
Niet bepaald.
Freezing Point
Niet bepaald.
Kinematic Viscosity
Not available
Relative Density
Not available
Colour
Geelachtig
Vapor Pressure
233 hPa (67-64-1 aceton) bij 20 °C; 800 hPa bij 50 °C
Lower Explosive Limit
2,6 Vol %
Melting Point
Niet bepaald.
Critical Property
Solubility In Water
Niet resp. gering mengbaar.
Density
0,84 g/cm³
Critical Property
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

Niet spuiten in de richting van een vlam of een gloeiend voorwerp.

Ontstekingsbronnen op afstand houden - niet roken.

Houder onder druk.

Beschermen tegen de zon en niet blootstellen aan een hogere temperatuur dan 50°C, bijv.

door gloeilampen.

Ook na gebruik niet doorboren of verbranden.

Storage Conditions

Beschermen tegen de zon en niet blootstellen aan een hogere temperatuur dan 50°C.

De overheidsbepalingen m.

b.

t.

de opslag van drukgaspakkingen moeten in acht genomen worden.

Tanks ondoordringbaar gesloten houden.

Fire Prevention Measures

Niet spuiten in de richting van een vlam of een gloeiend voorwerp. Ontstekingsbronnen op afstand houden - niet roken.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Veiligheidshandschoenen. Handschoenen uit butyl rubber(EN374, EN388:4101). Permeatiedoorbraaktijden volgens EN374-3:2003(minuten) > 480 minuten. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Tijdens het dragen van beschermende handschoenen is het aan te bevelen om katoenen onderhandschoenen(voor éénmalig gebruik) te dragen. Deze onderhandschoenen dienen na gebruik weggegooid te worden ter voorkoming van potentiële blootstelling aan geabsorbeerd product. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vóór het gebruik worden getest. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee. Voor een langdurig contact zijn handschoenen uit de volgende materialen geschikt: Butylrubber. Voor een contact van maximaal 15 minuten zijn handschoenen uit de volgende materialen geschikt: Butylrubber.

Eye Protection

Nauw aansluitende veiligheidsbril. Veiligheidsbril (EN166)

Respiratory Protection

Bij onvoldoende ventilatie ademhalingsbescherming. Het zuurstofgehalte van de ingeademde lucht moet voldoende zijn > 17%. Bij korte of geringe belasting ademfiltertoestel; bij intensieve resp. langdurige expositie een van de omringende lucht onafhankelijk ademhalingstoestel gebruiken. Filter AXP3(EN371)

Skin/Body Protection

Draag geschikte beschermende arbeidskleding(EN 340, 463, 468, 943-1, 943-2).

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Geen afbraak bij opslag en handling volgens voorschrift.

Reactivity

Geen verdere relevante informatie verkrijgbaar.

Hazardous Reactions

Geen gevaarlijke reacties bekend.

Conditions to Avoid

Geen verdere relevante informatie verkrijgbaar.

Incompatible Materials

Oxiderende stoffen

Hazardous Decomposition Products

Geen gevaarlijke ontbindingsprodukten bekend.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Product Disposal Recommendations

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1950

Proper Shipping Name

SPUITBUSSEN

Transport Hazard Class

2.1

Packing Group

vervalt

ADR Transport Precautions

Waarschuwing: Gassen

IMDG Maritime Transport Precautions

Waarschuwing: Gassen

IATA Air Transport Precautions

Waarschuwing: Gassen

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for POWER SPRAY?

The signal word for this substance is "danger".

What is the physical form of POWER SPRAY?

POWER SPRAY is a aërosol appearing as arosol with geelachtig color. It has oplosmiddelachtig odor.

What is POWER SPRAY used for?

Kleefmiddel

What are the hazard statements for POWER SPRAY?

This substance has 5 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of POWER SPRAY?

The melting point is Niet bepaald. and the boiling point is 55,8-56,6 °C.