NextSDS Logo
Safety Data Sheet NL

Zinc

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Zinc
Product Form
Spuitbus

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Verven

Manufacturers & Suppliers

C

CRC Industries Europe bvba

manufacturer

Touwslagerstraat 1, 9240 Zele, Belgium

C

CRC Industries Finland Oy

distributor

Asemanrinne 13, 08500 Lohja

+358/(19)32.921

C

CRC Industries France

distributor

6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex

01.34.11.20.00

C

CRC Industries Deutschland GmbH

distributor

Sdring 9, D-76473 Iffezheim

(07229) 303.0

C

CRC INDUSTRIES IBERIA S.L.U.

distributor

GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA

0034/921.427.546

C

CRC Industries Sweden

distributor

Kryptongatan 14, 431 53 Mlndal

0046/31 706 84

Emergency Contacts

CRC Industries Europe

+32(0)52/45.60.11

kantooruren

Nationaal vergiftigingen informatie centrum

030 274 88 88

Antigifcentrum

070 - 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

STOT RE
STOT SE
Flam. Liq.
Aquatic Acute
Aquatic Chronic

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
dimethylether EC: 204-065-8 115-10-6 30 - 60% Yes
zinkpoeder - zinkstof(gestabiliseerd) EC: 231-175-3 7440-66-6 10 - 30% Yes
Koolwaterstoffen, C6-7, n-alkanen, isoalkanene, cyclische, < 5% n- hexaan EC: 921-024-6 --- 5 - 10% Yes
butanon; ethylmethylketon EC: 201-159-0 78-93-3 10% Yes
zinkoxide EC: 215-222-5 1314-13-2 1 - 5% Yes
nafta (aardolie), met waterstof behandeld licht EC: 265-151-9 64742-49-0 1 - 5% Yes
nafta (aardolie), met waterstof ontzwaveld zwaar EC: 265-185-4 64742-82-1 1 - 5% Yes
1,2,4-trimethylbenzeen EC: 202-436-9 95-63-6 1% Yes
2-(3-heptyl)-N-butyl-1,3-oxazolane EC: 425-660-0 165101-57-5 1% Yes
butaan-1-ol EC: 200-751-6 71-36-3 2.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht, warm en rustig houden. Een arts raadplegen als er nadelige gevolgen optreden.

Symptoms: Overmatige inademing van dampen van oplosmiddel kan misselijkheid, hoofdpijn en duizeligheid veroorzaken.

Skin contact

Wassen met water en zeep. Als irritatie niet verdwijnt, een arts raadplegen.

Symptoms: Kan irritatie veroorzaken. Symptomen: roodheid en pijn.

Eye contact

Als de stof in de ogen komt, onmiddellijk met veel water uitspoelen. Als irritatie niet verdwijnt, een arts raadplegen.

Symptoms: Kan irritatie veroorzaken. Symptomen: roodheid en pijn.

Ingestion

Bij inslikken niet laten braken vanwege het risico van inademing in de longen. Als u vermoedt dat dit gebeurd is, onmiddellijk een arts raadplegen.

Symptoms: Bij inname niet doen braken. Gevaar voor chemische pneumonie. Symptomen: pijnlijke keel, buikpijn, misselijkheid, braken.

Immediate Medical Attention

Als u vermoedt dat inslikken gebeurd is, onmiddellijk een arts raadplegen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Voor voldoende ventilatie zorgen. Uit de buurt van warmte en van ontstekingsbronnen houden. Maatregelen treffen tegen ontladingen van statische elektriciteit.

Hands

Draag geschikte handschoenen

Eyes

Draag een veiligheidsbril.

Respiratory

Bij ontoereikende ventilatie een geschikt ademhalingsbeschuttingsmiddel dragen. Luchtzuiverend organisch gas/dampmasker (type A of AX)

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Vloestof in spuitbus met DME drijfgas.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Vloestof in spuitbus met DME drijfgas.
Colour
Grijs.
Colour Intensity
---
Form
---
Odor
Karakteristieke geur.
Odor Threshold
---
Ph
Niet van toepassing.
Melting Point
---
Boiling Point
Niet gekend.
Flash Point
< 0 C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
Niet gekend.
Evaporation Rate
---
Vapor Pressure
Niet gekend.
Vapor Density
---
Relative Density
1.45 g/cm3 (@ 20C)
Bulk Density
---
Density
1.45 g/cm3 (@ 20C)
Flammability
---
Upper Explosive Limit
Niet gekend.
Lower Explosive Limit
Niet gekend.
Explosive Limits
---
Auto Ignition Temperature
- 200 C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Niet oplosbaar in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
640 g/l
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
SPUITBUSSEN (AROSOLEN)
Transport Class
2.1
Packing Group
Niet van toepassing.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Zinc?

The signal word is na: r-phrases.

What is the physical form of Zinc?

Zinc is a vloestof in spuitbus met dme drijfgas. appearing as vloestof in spuitbus met dme drijfgas. with grijs. color. It has karakteristieke geur. odor.

What is Zinc used for?

Verven

Compliance Scanner

Scan your compliance