NextSDS Logo
Se

Sencys Houtlijm Universeel

NO SIGNAL WORD Vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Sencys Houtlijm Universeel
Product Form
Mengsel

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Dispersie Lijm Coating
Uses Advised Against
Geen aanvullende informatie beschikbaar

Overview

Sencys Houtlijm Universeel is a vloeibaar. substance commonly used dispersie lijm coating.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Soudal N.V. company logo - Safety Data Sheet supplier organization

Soudal N.V.

distributor

Everdongenlaan 18-20 2300 Turnhout Belgium

BE

+32 14 42 42 31

+32 14 42 65 14

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 88 755 80 00

NL

24 uur per dag en 7 dagen in de week

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
propyleencarbonaat
EC: 203-572-1
108-32-7 5% Hazardous
reactiemassa (3:1) van 5-chloor-2-methyl-2H-isothiazool-3-on en 2-methyl-2H-isothiazool-3-on 55965-84-9 0.0015% Hazardous

Composition Notes

Volledige tekst van H- en EUH-zinnen: zie sectie 16

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.

Symptoms:

ademhalingsproblemen

Skin Contact

De huid met overvloedig water wassen.

Symptoms:

huidirritatie of uitslag

Eye Contact

Als voorzorgsmaatregel de ogen met water uitspoelen. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen.

Symptoms:

irritatie

Ingestion/Swallowing

Mond met water spoelen.

Symptoms:

onwel voelen

Medical Treatment

Symptomatische behandeling.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Dynamic Viscosity
10000 – 40000 mPa·s (DIN EN ISO 2555)
Melting Point
≈ 0 °C
Critical Property
Relative Evaporation Rate
Not available
Solubility
Niet beschikbaar
Upper Explosive Limit
Niet beschikbaar
Odor
Milde geur.
Relative Density
1,1
Decomposition Temperature
Niet beschikbaar
State Under Standard Conditions
Not available
Vapor Pressure
23 hPa (20°C)
Cloud Point
Not available
Solidification Point
Not available
Colour
Niet beschikbaar
Auto Ignition Temperature
Niet beschikbaar
Properties Status
Not available
Lower Explosive Limit
Niet beschikbaar
Evaporation Rate
Not available
Solubility In Fat
Not available
Physical State
Vloeibaar
Critical Property
Partition Coefficient
Niet beschikbaar
Vapor Density
Not available
Voc Content
0 %
Form
Not available
Softening Point
Not available
Molecular Weight
Not available
Flammability
Niet van toepassing
Odor Threshold
Niet beschikbaar
Appearance
Vloeibaar.
Bulk Density
Not available
Kinematic Viscosity
Niet beschikbaar
Freezing Point
Niet beschikbaar
Ph
2,5 – 6 (DIN ISO 976)
Boiling Point
≈ 100 °C (1013 hPa)
Critical Property
Density
1,1 g/cm³ (20°C)
Critical Property
Colour Intensity
Not available
Solubility In Water
Not available
Flash Point
Niet beschikbaar
Critical Property
Explosive Limits
Not available
Metal Corrosion
Not available
Physical State Data
liquid
Crystallisation Point
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Zorg voor een goede ventilatie van de werkplek.

Hand Protection

Beschermende handschoenen tegen chemicaliën (EN 374)

Eye Protection

Veiligheidsbril (EN 166)

Respiratory Protection

Bij ontoereikende ventilatie een geschikt ademhalingsapparaat gebruiken

Skin/Body Protection

Beschermende kleding (EN 14605 of EN 13034)

Environmental Exposure Controls

Voorkom lozing in het milieu.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stabiel onder normale omstandigheden.

Reactivity

Het product is onder normale gebruiks-, opslag- en transportcondities niet reactief.

Hazardous Reactions

Geen gevaarlijke reacties bekend onder normale gebruiksomstandigheden.

Conditions to Avoid

Geen onder aanbevolen opslag- en hanteringscondities (zie lid 7).

Incompatible Materials

Geen aanvullende informatie beschikbaar

Hazardous Decomposition Products

Onder normale opslag- en gebruiksvoorwaarden zullen er geen gevaarlijke ontledingsproducten ontstaan.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

Niet gereglementeerd

Proper Shipping Name

Niet gereglementeerd

Transport Hazard Class

Niet gereglementeerd

Packing Group

Niet gereglementeerd

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Sencys Houtlijm Universeel?

The signal word for this substance is "no signal word".

What is the physical form of Sencys Houtlijm Universeel?

Sencys Houtlijm Universeel is a vloeibaar appearing as vloeibaar. with niet beschikbaar color. It has milde geur. odor.

What is the solubility of Sencys Houtlijm Universeel?

Niet beschikbaar

What is Sencys Houtlijm Universeel used for?

Dispersie Lijm Coating

What is the melting point of Sencys Houtlijm Universeel?

The melting point is ≈ 0 °C and the boiling point is ≈ 100 °C (1013 hPa).