NextSDS Logo
Safety Data Sheet NL

AMSTERDAM SPRAYPAINT

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AMSTERDAM SPRAYPAINT
Product Code
17.16.xxxx

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Kunstschildersverf

Manufacturers & Suppliers

R

Royal Talens

manufacturer

P.O.Box 4 NL-7300 AA Apeldoorn

+31 (0)55 5274700

Emergency Contacts

Nationaal Vergiftigingen Informatie Centrum (Bilthoven)

(31) 030 2748888

Antigifcentrum (Brussel)

(32) 070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aerosol Cat. 2 H223

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mengsel van hieronder genoemde stoffen met ongevaarlijke toevoegingen.

Chemical Name CAS Number Concentration Hazardous
dimethylether EC: 204-065-8 115-10-6 25 - 50% Yes
ethanol EC: 200-578-6 64-17-5 10 - 25% Yes

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

Notes

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Niet van toepassing.

Eye contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen

Ingestion

Geen braken teweegbrengen en onmiddellijk medische hulp raadplegen.

Immediate Medical Attention

Geen verdere relevante informatie verkrijgbaar.

Medical Treatment

Geen verdere relevante informatie verkrijgbaar.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Co2, bluspoeder, schuim, waternevel

Unsuitable media

Krachtige waterstraal

Specific hazards

Bij verhitting of brand is het ontstaan van giftige gassen/dampen mogelijk.

Firefighter Protection

Geen bijzondere maatregelen nodig.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ontstekingsbronnen verwijderd houden.

Environmental

Geen speciale maatregelen noodzakelijk.

Cleanup methods

Voor voldoende ventilatie zorgen.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Tanks vorzichtig openen en behandelen. Niet spuiten in de richting van een vlam of een gloeiend voorwerp. Ontstekingsbronnen op afstand houden - niet roken. Maatregelen treffen tegen ontlading van statische elektriciteit.

Storage

Op een koele plaats bewaren. De overheidsbepalingen m.b.t. de opslag van drukgaspakkingen moeten in acht genomen worden. Tanks niet gasdicht afsluiten. Koel en droog bewaren in goed gesloten vaten. Tegen hitte en directe zonnestralen beschermen.

Fire prevention

Niet spuiten in de richting van een vlam of een gloeiend voorwerp. Ontstekingsbronnen op afstand houden - niet roken.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handschoenmateriaal Butylrubber. Doordringingstijd van het handschoenmateriaal Niet van toepassing.

Eyes

Niet noodzakelijk.

Respiratory

Bij onvoldoende ventilatie ademhalingsbescherming.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aërosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
---
Colour
Volgens de produktbeschrijving
Colour Intensity
---
Form
Aërosol
Odor
Waarneembaar
Odor Threshold
---
Ph
Niet bruikbaar.
Melting Point
Niet bepaald.
Boiling Point
-24 °C
Flash Point
-42 °C
Freezing Point
Niet bepaald.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Niet bepaald.
Vapor Pressure
5.200 hPa
Vapor Density
Niet bruikbaar.
Relative Density
---
Bulk Density
---
Density
0,85 g/cm³
Flammability
Niet bruikbaar.
Upper Explosive Limit
18,6 Vol %
Lower Explosive Limit
3 Vol %
Explosive Limits
---
Auto Ignition Temperature
235 °C
Decomposition Temperature
Niet bepaald.
Solubility
Volledig mengbaar.
Partition Coefficient
Niet bepaald.
Solubility In Water
Volledig mengbaar.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Niet bruikbaar.
Kinematic Viscosity
Niet bruikbaar.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Bij opslag en gebruik zoals voorgeschreven (zie sectie 7) stabiel.

Reactivity

Bij gebruik overeenkomstig de bestemming zijn er geen gevaarlijke reacties te verwachten.

Hazardous reactions

Bij gebruik overeenkomstig de bestemming zijn er geen gevaarlijke reacties te verwachten.

Avoid

Verwijderd houden van ontstekingsbronnen - Niet roken.

Incompatible

Geen verdere relevante informatie verkrijgbaar.

Decomposition

Geen ontleding bij gebruik volgens voorschrift.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
Niet van toepassing.
Transport Class
2
Packing Group
vervalt
ADR

Waarschuwing: Gassen

IMDG

Waarschuwing: Gassen

IATA

Waarschuwing: Gassen

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AMSTERDAM SPRAYPAINT?

The signal word is no signal word.

What is the physical form of AMSTERDAM SPRAYPAINT?

AMSTERDAM SPRAYPAINT is a aërosol with volgens de produktbeschrijving color. It has waarneembaar odor.

What is the solubility of AMSTERDAM SPRAYPAINT?

Volledig mengbaar.

What is AMSTERDAM SPRAYPAINT used for?

Kunstschildersverf

What is the melting point of AMSTERDAM SPRAYPAINT?

The melting point is Niet bepaald. and the boiling point is -24 °C.