NextSDS Logo
Co

Contact Cleaner Plus

DANGER Vloeistof. Aerosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Contact Cleaner Plus
Product Code
BDS002284AE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reinigers - precisie
Uses Advised Against
Niet bekend.

Overview

Contact Cleaner Plus commonly used reinigers - precisie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Skin Irrit. Category 2 H315
STOT SE Category 3 H336
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol.
  • H229: Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P271: Alleen buiten of in een goed geventileerde ruimte gebruiken.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 /122F.
  • P501: Inhoud/verpakking afvoeren overeenkomstig de plaatselijke/regionale/nationale/internationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe bv company logo - Safety Data Sheet supplier organization

CRC Industries Europe bv

manufacturer

πŸ“

Touwslagerstraat 1 9240 Zele Belgi

🌍

BE

πŸ“ 

+32(0)52/45.00.34

🌐 www.crcind.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CRC Industries Europe bv

πŸ“ž

+32(0)52/45.60.11

🌍

BE

πŸ•’

(office hours)

Algemeen in EU

πŸ“ž

112

πŸ•’

24 uur per dag bereikbaar

πŸ’‘

Veiligheidsinformatieblad/Productinformatie is mogelijk niet beschikbaar voor de hulpdiensten.

Nationaal vergiftigingencentrum

πŸ“ž

070 245 245

🌍

BE

πŸ•’

24 uur per dag bereikbaar

πŸ’‘

Veiligheidsinformatieblad/Productinformatie is mogelijk niet beschikbaar voor de hulpdiensten.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Alle concentraties worden uitgedrukt in massaprocent, tenzij het een gas betreft. Gasconcentraties worden uitgedrukt in volumeprocent.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
koolwaterstoffen ,C6,isoalkanen ,< 5% n-hexane N/A 25-50% ⚠️ Hazardous
pentaan stof met nationale blootstellingsgrenswaarde(n) op de werkvloer (BE); stof waarvoor binnen de Gemeenschap een blootstellingsgrens op de werkvloer geldt
EC: 203-692-4
109-66-0 25-50% ⚠️ Hazardous
Koolwaterstof , C6-C7, n-alkanen ,isoalkanen ,cyclische ,< 5% n-hexane N/A 10-25% ⚠️ Hazardous
5% CO2 IN AIR, HIGH LEVEL CALIBRANT GAS
EC: 204-696-9
124-38-9 1-5% ⚠️ Hazardous
Koolwaterstof , C11-C14, n-alkanen , isoalkanen , cyclische ,< 2% aromatics N/A 1-5% ⚠️ Hazardous

Composition Notes

De volledige tekst van alle H-zinnen wordt weergegeven in rubriek 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Het slachtoffer in de frisse lucht brengen en laten rusten in een houding die het ademen vergemakkelijkt. Bij onwel voelen een antigifcentrum of een arts raadplegen.

πŸ–οΈ Skin Contact

Besmette kleding verwijderen. Met veel water en zeep wassen. Bij huidirritatie: een arts raadplegen. Verontreinigde kleding wassen alvorens deze opnieuw te gebruiken.

πŸ‘οΈ Eye Contact

Met water afspoelen. Wanneer irritatie ontstaat en aanhoudt, dient u medische hulp in te roepen.

🍽️ Ingestion/Swallowing

In het onwaarschijnlijke geval van inslikken een arts of vergiftigingencentrum raadplegen. De mond spoelen.

🚨 Immediate Medical Attention Required

Zorg voor algemene ondersteunende maatregelen en behandel symptomatisch. Houd slachtoffer onder observatie. De symptomen kunnen met vertraging optreden.

Medical Treatment

Zorg voor algemene ondersteunende maatregelen en behandel symptomatisch.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ“Š Decomposition Temperature
Niet beschikbaar.
πŸ“Š Cloud Point
Not available
πŸ“Š Softening Point
Not available
πŸ’¨ Vapor Pressure
3645,9 hPa geschat
πŸ“Š Upper Explosive Limit
7,8 % geschat
πŸ“Š Odor Threshold
Not available
πŸ“Š Relative Density
0,67 g/cm3
πŸ“Š Bulk Density
Not available
πŸ”₯ Flammability
Niet beschikbaar.
πŸ“Š Form
Not available
πŸ“Š Solidification Point
Not available
🎨 Colour
Kleurloos.
πŸ§ͺ Ph
Niet van toepassing.
πŸ‘ƒ Odor
Oplosmiddel.
πŸ“Š Partition Coefficient
Not available
πŸ“Š Explosive Limits
Not available
πŸ“Š Molecular Weight
Not available
πŸ’§ Solubility
Not available
πŸ’¨ Boiling Point
Niet beschikbaar.
Critical Property
πŸ“Š Auto Ignition Temperature
> 200 (> 392 F)
πŸ’¨ Evaporation Rate
Not available
πŸ“Š Colour Intensity
Not available
βš–οΈ Density
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Physical State Data
liquid
πŸ§ͺ Physical State
Vloeistof. Aerosol
Critical Property
πŸ“Š Freezing Point
-129,7 (-201,5 F) geschat
πŸ“Š State Under Standard Conditions
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Solubility In Water
Onoplosbaar in water
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Lower Explosive Limit
1,5 % geschat
πŸ“Š Voc Content
700 g/l
πŸ“Š Kinematic Viscosity
Not available
πŸ‘οΈ Appearance
Not available
πŸ“Š Vapor Density
Niet beschikbaar.
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Properties Status
Not available
🧊 Melting Point
-129,7 (-201,5 F) geschat
Critical Property
πŸ”₯ Flash Point
< 0 (< 32,0 F) Gesloten beker (closed cup)
Critical Property

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Er moet een goede algehele ventilatie worden gebruikt. Ventiliatiesnelheden moeten zijn aangepast aan de omstandigheden. Gebruik, indien van toepassing, afgesloten procesruimten, plaatselijke afzuiging of andere technische middelen om de concentraties in de lucht onder de aanbevolen blootstellingslimieten te houden. Wanneer er geen blootstellingslimieten zijn vastgesteld, houd dan de concentraties in de lucht op een aanvaardbaar niveau. Oogspoelstation en veiligheidsdouche verschaffen.

🧀 Hand Protection

Draag bij gebruik van het product handschoenen die beschemen tegen chemicaliΓ«n (EN 374 norm). De doorbraaktijd van de handschoen moet langer zijn dan de totale duur van het gebruik van het product. Als de werkzaamheden met het product langer duurt dan de doorbraaktijd van de handschoen, moet die tussenin vervangen worden. Volledig contact: Handschoenmateriaal: nitril. Gebruik handschoenen met doorbraaktijd van 480 minuten. Minimum dikte van handschoenen 0.38 mm.

πŸ‘οΈ Eye Protection

Draag een veiligheidsbril met zij-afscherming (of een veiligheidsbril die geheel op het gezicht aansluit). Gebruik oogbescherming conform EN 166.

😷 Respiratory Protection

Bij ontoereikende ventilatie een geschikte adembescherming dragen. CCR met ademhalingsuitrusting die tegen organische damp beschermt en volledig gezichtsstuk. (Filter type AX)

🦺 Skin/Body Protection

Geschikte chemisch-resistente kleding dragen.

🌍 Environmental Exposure Controls

Breng het hiervoor aangewezen leidinggevend of toezichthoudend personeel altijd op de hoogte wanneer een stof onbedoeld vrijkomt. Emissies van ventilatie- of procesapparatuur moet worden gecontroleerd om na te gaan dat zij voldoen aan de vereisten van milieubeschermingswetten. Rookgaswassers, filters of technische aanpassingen aan de procesapparatuur kunnen nodig zijn om de emissies tot aanvaardbaar niveaus te brengen.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

πŸ“¦ Proper Shipping Name

AEROSOLEN

⚠️ Transport Hazard Class

2.1

πŸ“‹ Packing Group

Niet van toepassing

πŸš› ADR Transport Precautions

Lees voor gebruik de veiligheidsinstructies, het veiligheidsinformatieblad en de noodprocedures.

🚒 IMDG Maritime Transport Precautions

Read safety instructions, SDS and emergency procedures before handling.

✈️ IATA Air Transport Precautions

Read safety instructions, SDS and emergency procedures before handling.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Contact Cleaner Plus?

The signal word for this substance is "danger".

What is the physical form of Contact Cleaner Plus?

Contact Cleaner Plus is a vloeistof. aerosol with kleurloos. color. It has oplosmiddel. odor.

What is Contact Cleaner Plus used for?

Reinigers - precisie

What are the hazard statements for Contact Cleaner Plus?

This substance has 5 hazard statements: H222: Zeer licht ontvlambare aerosol. H229: Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of Contact Cleaner Plus?

The melting point is -129,7 (-201,5 F) geschat and the boiling point is Niet beschikbaar..