NextSDS Logo
P3

P3

NO SIGNAL WORD vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
P3
Product Code
PK_0001_M

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Productiemiddel/smeermiddel voor vacumpompen

Overview

P3 commonly used productiemiddel/smeermiddel voor vacumpompen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PFEIFFER VACUUM GmbH company logo - Safety Data Sheet supplier organization

PFEIFFER VACUUM GmbH

manufacturer

๐Ÿ“

Berliner Strasse 43 D-35614 Asslar

๐ŸŒ

DE

๐Ÿ“ž

+49 6441 / 802-0

๐Ÿ“ 

+49 6441 / 802-1202

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Natonaal Vergiftigingen Informatie Centrum (NVIC)

๐Ÿ“ž

+31-30-274 88 88

๐ŸŒ

NL

๐Ÿ’ก

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mengsels

General Composition

Uiterst geraffineerde minerale olin en toevoegingen.

Additional Information

IP346 = "Institute of Petroleum" (IP) Testmethode nr. 346 voor de bepaling van polycyclische aromaten DMSO-extraheerbaar

Composition Notes

De uiterst geraffineerde minerale olie bevat volgens IP 346 een dimethylsulfoxide (DMSO)-extraheerbaar gehalte van minder dan 3 % (w/w).

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Frisse lucht toevoeren; bij klachten een arts opzoeken.

๐Ÿ–๏ธ Skin Contact

Vervuilde kleding en schoenen verwijderen. Met water en zeep afwassen. Wanneer de huid gerriteerd blijft, een dokter opzoeken.

๐Ÿ‘๏ธ Eye Contact

Ogen bij geopend ooglid een aantal minuten met stromend water spoelen

๐Ÿฝ๏ธ Ingestion/Swallowing

Na inslikken van aanmerkelijke hoeveelheden arts bezoeken.

Symptoms:

Misselijkheid. Overgeven diarree

Medical Treatment

Symptomatische behandeling

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Vapor Density
Not available
๐ŸงŠ Melting Point
-9 C
Critical Property
๐Ÿ“Š Relative Density
0,866
๐Ÿ’จ Evaporation Rate
Niet bepaald.
๐Ÿ“Š Kinematic Viscosity
95 mm/s
๐Ÿ“Š Decomposition Temperature
niet bepaald
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ“Š Dynamic Viscosity
Niet bepaald.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Upper Explosive Limit
10 Vol % (based on mineral oil)
๐Ÿ“Š Cloud Point
Not available
๐ŸŽจ Colour
geelachtig
๐Ÿ“Š Freezing Point
Not available
๐Ÿ”ฅ Flammability
Niet bruikbaar.
๐Ÿงช Physical State
vloeibaar
Critical Property
๐Ÿ‘ƒ Odor
licht naar koolwaterstoffen
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š Partition Coefficient
- 6 log POW (similar products)
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Lower Explosive Limit
1 Vol %
๐Ÿ”ฅ Flash Point
260 C (open cup)
Critical Property
โš–๏ธ Density
0,866 g/cm
Critical Property
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿงช Ph
niet bruikbaar
๐Ÿ“Š Properties Status
Not available
๐Ÿ’จ Vapor Pressure
Niet bepaald.
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Odor Threshold
Niet bepaald.
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Solubility In Water
niet resp. gering mengbaar
๐Ÿ’จ Boiling Point
- 280 C (estimated)
Critical Property
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Form
vloeibaar
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Auto Ignition Temperature
- 320 C
๐Ÿ“Š State Under Standard Conditions
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

๐Ÿงค Hand Protection

Chemicalinbestendige veiligheidshandschoenen (EN 374). Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Keuze van het materiaal voor de handschoenen op basis van de penetratietijd, graad van doordringbaarheid en de afbreekbaarheid. Aanbevolen handschoenmaterialen: Nitrielrubber, PVC, Neopreen. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vr het gebruik worden getest. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee. > 480 minuten.

๐Ÿ‘๏ธ Eye Protection

Veiligheidsbril. Volledig masker. Conform EN 166.

๐Ÿ˜ท Respiratory Protection

Niet vereist indien de gebruiksvoorwaarden in acht genomen worden. Bij overschrijding van de luchtgrenswaarde en ongecontroleerd vrijkomen van stof: Ademhalingsbescherming aanbevolen. Als normale filtersystemen geschikt zijn, zeker de gepaste combinatie van filter en masker kiezen. Een combinatiefilter voor deeltjes, gassen en dampen (kookpunt>65 C, 149F).

๐Ÿฆบ Skin/Body Protection

Draag geschikte beschermende arbeidskleding. Dragen van veiligheidsschoenen.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for P3?

The signal word for this substance is "no signal word".

What is the physical form of P3?

P3 is a vloeibaar with geelachtig color. It has licht naar koolwaterstoffen odor.

What is P3 used for?

Productiemiddel/smeermiddel voor vacumpompen

What is the melting point of P3?

The melting point is -9 C and the boiling point is - 280 C (estimated).