Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur
- Product Code
- 1.05680
- Chemical Name
- Lithiumcarbonaat
Regulatory Identifiers
- CAS Number
- 554-13-2 Check regulations →
- REACH No.
- 01-2119516034-53-XXXX
Identified Uses
Reagens voor analyse
Manufacturers & Suppliers
Millipore
distributor
Merck Life Science BV/SRL
distributor
Brusselsesteenweg 288, B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lithiumcarbonaat EC: 209-062-5 | 554-13-2 | 100% | Yes |
Voor de volledige text van H-zinnen zoals vermeld in deze paragraaf, zie paragraaf 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Na inhalatie: frisse lucht.
Bij aanraking met de huid: Verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/ afdouchen.
Na oog contact: uitspoelen met ruim voldoende water. Oogarts raadplegen. Contactlenzen uitnemen.
Na inslikken: slachtoffer onmiddellijk water laten drinken (niet meer dan twee glazen). Een arts raadplegen.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Gebruik blusmiddelen die geschikt zijn voor de plaatselijke omstandigheden en de omgeving.
Voor deze stof / dit mengsel gelden geen beperkingen voor blusmiddelen.
Niet brandbaar. Door brand in de omgeving is het ontstaan van gevaarlijke dampen mogelijk.
Firefighter Protection
Bij brand een persluchtmasker dragen.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Vermijd stofinhalatie. Vermijd contact met de stof. Zorg voor voldoende ventilatie. Gevarenzone ontruimen, noodprocedures volgen, een deskundige raadplegen.
Droog opnemen. Vervuild oppervlak schoonmaken.
Related Products
Similar products with comparable safety profiles
Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur
CAS: 554-13-2
Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur
CAS: 554-13-2
Kaliumcarbonaat voor analyse EMSURE® ACS, ISO, Reag. Ph Eur
CAS: 584-08-7
Kaliumcarbonaat voor analyse EMSURE® ACS,ISO,Reag. Ph Eur
---
Natriumwaterstofcarbonaat voor analyse EMSURE® ACS,Reag.Ph Eur
CAS: 144-55-8
Aceton voor analyse EMSURE® ACS, ISO, Reag. Ph Eur
---
Aceton voor analyse EMSURE® ACS, ISO, Reag. Ph Eur
CAS: 67-64-1
Lood(II)-carbonaat voor analyse EMSURE® ACS
CAS: 598-63-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Voor voorzorgsmaatregelen zie hoofdstuk 2.2
Goed afgesloten. Droog.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Materiaal: Nitrilrubber; Minimale laagdikte: 0,11 mm; Doorbraaktijd: 480 min; Getest materiaal: KCL 741 Dermatril® L; Normen: EN374
beschermbril; Normen: NIOSH (US) of EN166 (EU)
nodig indien stofvorming plaatsvindt; Aanbevolen filtertype: Filter type P2; Normen: DIN EN 143, DIN 14387
beschermende kleding
Product niet in de riolering laten komen.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Het product is chemisch stabiel onder standaard omgevingsvoorwaarden (ka mertemperatuur).
Geen gegevens beschikbaar
Kans op ontbranding of vorming van brandbare gassen of dampen met: Fluor, Aardalkalimetalen
geen informatie beschikbaar
Geen gegevens beschikbaar
In geval van brand: zie hoofdstuk 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Afvalmaterialen moeten worden afgevoerd in overeenstemming met de nation a stoffen in de origin ele verpakking en zorg ervoor dat deze niet worden gemengd met ander afv al.
Afvalmaterialen moeten worden afgevoerd in overeenstemming met de nation a stoffen in de origin ele verpakking en zorg ervoor dat deze niet worden gemengd met ander afv al.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Niet-gevaarlijke goederen
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Dit veiligheidsinformatieblad voldoet aan de eisen van Verordening (EG) Nummer 1907/2006. Werkrestricties gericht op de bescherming van werkneemsters tijdens de zw eventuele striktere nationale regelgeving in acht nemen.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur?
The signal word is warning.
What is the physical form of Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur?
Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur is a vast with wit color. It has reukloos odor.
What is Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur used for?
Reagens voor analyse
What are the hazard statements for Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur?
This substance has 2 hazard statements:
- H302: Schadelijk bij inslikken.
- H319: Veroorzaakt ernstige oogirritatie.
What is the melting point of Lithiumcarbonaat voor analyse EMSURE® ACS, Reag. Ph Eur?
The melting point is 722 °C and the boiling point is Geen gegevens beschikbaar.