NextSDS Logo
DY

DYK CLEANER TI 1L*12 NLFR

DANGER Vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DYK CLEANER TI 1L*12 NLFR
Product Code
606-002-00-3
Chemical Name
Methylethyl ketone

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Reinigingsmiddel

Overview

DYK CLEANER TI 1L*12 NLFR (CAS: 78-93-3 ) commonly used reinigingsmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Licht ontvlambare vloeistof en damp.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P261: Inademing van damp vermijden.
  • P403 + P233: Op een goed geventileerde plaats bewaren. In goed gesloten verpakking bewearen.
  • P501: De inhoud/verpakking afvoeren overeenkomstig de nationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

DYKA

manufacturer

๐Ÿ“

Produktieweg 7 NL-8331 LJ STEENWIJK PO Box 33 NL-8330 AA STEENWIJK

๐ŸŒ

NL

๐Ÿ“ž

+31 521 534911

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

๐Ÿ“ž

070 245245

๐ŸŒ

BE

Emergency Contact

๐Ÿ“ž

8002 - 5500

๐ŸŒ

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N/A N/A Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden.

๐Ÿ‘๏ธ Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Als de klachten niet minderen, een arts raadplegen

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Waternevel, Alcoholbestendig schuim, Bluspoeder, Kooldioxyde

โŒ Unsuitable Extinguishing Media

Krachtige waterstraat

โš ๏ธ Specific Fire Hazards

Geen verdere relevante informatie verkrijgbaar.

๐Ÿ”ฅ Fire Fighting Instructions

De aan gevaar blootgestelde tanks met watersproeistraal koelen.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Geen bijzondere maatregelen nodig.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

Beschernende kleding aantrekken. Niet beschermde personen op afstand houden.

๐ŸŒ Environmental Precautions

Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

๐Ÿงน Cleanup Methods

In special tanks voor terugwinning of berging verzamelen. Met vloeistofbindend materiaal (zand, bergmeel, zuurbinder, universele binder, zaagmeel) opnemen.

Cleanup Materials:

vloeistofbindend materiaal (zand, bergmeel, zuurbinder, universele binder, zaagmeel)

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Relative Density
Niet bepaald.
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,804-0,807 g/cm
Critical Property
๐Ÿ‘ƒ Odor
Ketonachtig
๐Ÿ“Š Auto Ignition Temperature
514 C
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Form
Vloeibaar
๐Ÿ“Š Upper Explosive Limit
11,5 Vol %
๐Ÿ“Š Lower Explosive Limit
1,8 Vol %
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿงช Physical State
Vloeibaar
Critical Property
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Dynamic Viscosity
0,4 mPas
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Odor Threshold
Niet bepaald.
๐Ÿ“Š Crystallisation Point
Not available
๐ŸŽจ Colour
Kleurloos
๐Ÿ“Š Metal Corrosion
Niet van toepassing
๐Ÿ“Š Properties Status
Not available
๐Ÿ’จ Vapor Pressure
105 hPa
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Molecular Weight
72,11 g/mol
๐Ÿ“Š Solubility In Water
290 g/l
๐Ÿ“Š Partition Coefficient
Niet bepaald.
๐Ÿ”ฅ Flammability
Licht ontvlambaar.
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š Vapor Density
Niet bepaald.
๐Ÿ“Š Kinematic Viscosity
Niet bepaald.
๐ŸงŠ Melting Point
-86,3 C
Critical Property
๐Ÿ“Š Decomposition Temperature
Niet bepaald.
๐Ÿ”ฅ Flash Point
-9 C
Critical Property
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ’จ Boiling Point
79-80,5 C
Critical Property
๐Ÿ“Š Voc Content
Not available
๐Ÿ’จ Evaporation Rate
Niet bepaald.
๐Ÿงช Ph
Niet bepaald.

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Voor een goede ventilatie zorgen (ook voor de vloeren) (dampen zijn zwaarder dan lucht).

โ€ข Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

โ€ข Arosolvorming vermijden.

โ€ข Onststekingsbronnen op afstand houden - niet roken.

โ€ข Maatregelen treffen tegen ontlading van statische elektriciteit.

๐Ÿช Storage Conditions

โ€ข Op een koele plaats bewaren.

โ€ข Tanks ondoordringbaar gesloten houden.

โ€ข Koel en droog bewaren in goed gesloten vaten.

๐Ÿ”ฅ Fire Prevention Measures

Onststekingsbronnen op afstand houden - niet roken.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Geen aanvullende gegevens. Zie 7.

๐Ÿงค Hand Protection

Handschoenen / bestand tegen oplosmiddelenHet handschoenmaterialaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding.Kies handschoenmaterialaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie.HandschoenmaterialaalAanbevolen materiaaldikte : > 0,12 mmButylrubberNitrilrubber Aanbevolen materiaaldikte : > 0,7 mm Doordringingstijd van het handschoenmaterial Voor het mengsel van de hieronder vermelde chemicalien moet de penetratietijd minstens 10 minuten bedragen (permeatie volgens EN 374 Deal 3: Level 1). Voor het mengsel van de hieronder vermelde chemicalien moet de penetratietijd minstens 120 minuten bedragen (permeatie volgens EN 374 Deal 3: Level 4).

๐Ÿ‘๏ธ Eye Protection

Nauw aansluitende veiligheidsbril Bij het omgieten is het gebruik van een veiligheidsbril aan te bevelen.

๐Ÿ˜ท Respiratory Protection

Bij onvoldoende ventilatie ademshalingsbescherming.Aanbevolen filter voor kortstondig gebruik: Filter A

๐Ÿฆบ Skin/Body Protection

Tegen oplosmiddelen bestande beschermingskleding

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

Geen afbraak bij gebruik volgens voorschrift.

โš—๏ธ Reactivity

Geen verdere relevante informatie verkrijgbaar.

โš ๏ธ Hazardous Reactions

Geen gevaarlijke reacties bekend.

๐Ÿšซ Conditions to Avoid

Geen verdere relevante informatie verkrijgbaar.

๐Ÿงช Incompatible Materials

Geen verdere relevante informatie verkrijgbaar.

๐Ÿ’จ Hazardous Decomposition Products

Gevaar voor vorming van toxische pyrolyseprodukten.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

๐Ÿ—‚๏ธ Product Disposal Recommendations

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen. Afvalverwijdering volgens overheidsbepalingen.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1193

๐Ÿ“ฆ Proper Shipping Name

ETHYL METHYL KETONE (METHYL ETHYL KETONE)

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

II

๐Ÿš› ADR Transport Precautions

Waarschuwing: Brandbare vloeistoffen

๐Ÿšข IMDG Maritime Transport Precautions

Waarschuwing: Brandbare vloeistoffen

โœˆ๏ธ IATA Air Transport Precautions

Waarschuwing: Brandbare vloeistoffen

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DYK CLEANER TI 1L*12 NLFR?

The signal word for this substance is "danger".

What is the physical form of DYK CLEANER TI 1L*12 NLFR?

DYK CLEANER TI 1L*12 NLFR is a vloeibaar with kleurloos color. It has ketonachtig odor.

What is DYK CLEANER TI 1L*12 NLFR used for?

Reinigingsmiddel

What are the hazard statements for DYK CLEANER TI 1L*12 NLFR?

This substance has 3 hazard statements: H225: Licht ontvlambare vloeistof en damp. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken.

What is the melting point of DYK CLEANER TI 1L*12 NLFR?

The melting point is -86,3 C and the boiling point is 79-80,5 C.