NextSDS Logo
Ma

MasterFinish RL 215

NO SIGNAL WORD vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
MasterFinish RL 215

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Product van bouwchemie

Overview

MasterFinish RL 215 commonly used product van bouwchemie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BASF Belgium Coordination Center Comm.V. Business Belux

distributor

๐Ÿ“

Drve Richelle 161 E/F 1410 WATERLOO, BELGIUM

๐ŸŒ

BE

๐Ÿ“ž

+32 2 373 27 77

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Antipoisons / Antigifcentrum

๐Ÿ“ž

+ 32 70 245 245

๐ŸŒ

BE

Emergency Contact

๐Ÿ“ž

+49 180 2273-112

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

op basis van: mineraalolie, plantaardige olien

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
destillaten (aardolie), met waterstof behandelde lichte paraffinehoudende; Basisolie - niet gespecificeerd
EC: 265-158-7
64742-55-8 3-7% โš ๏ธ Hazardous

Composition Notes

Indien in deze rubriek gevaarlijke inhoudsstoffen niet volledig worden vermeld, met inbegrip van de gevarenklassen en de gevarenaanduidingen, is de volledige tekst te vinden in rubriek 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Rust, frisse lucht. Bij aanhoudende klachten dokter raadplegen.

๐Ÿ–๏ธ Skin Contact

Na aanraking met de huid onmiddellijk wassen met veel water en zeep. In geen geval oplosmiddelen gebruiken. Indien irriterende effecten optreden, dokter raadplegen.

๐Ÿ‘๏ธ Eye Contact

15 minuten met opengesperde oogleden d.m.v. stromend water grondig spoelen, door oogarts laten controleren

๐Ÿฝ๏ธ Ingestion/Swallowing

Direct de mond spoelen en rijkelijk water drinken, doktershulp vragen. Braken enkel uitlokken wanneer dit door een antigifcentrum (BE) of vergiftigingeninformatiecentrum (NL) of een arts wordt opgedragen.

๐Ÿšจ Immediate Medical Attention Required

Behandeling: behandeling van de symptomen (verwijderen van de verontreinigende stof, controle van vitale functies).

Medical Treatment

behandeling van de symptomen (verwijderen van de verontreinigende stof, controle van vitale functies)

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ”ฅ Flammability
niet ontvlambaar
๐Ÿ’จ Vapor Pressure
niet van toepassing
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Properties Status
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Voc Content
Not available
โš–๏ธ Density
ca. 0,96 g/cm3
Critical Property
๐Ÿ’จ Boiling Point
ca. 100 C
Critical Property
๐Ÿ“Š Colour Intensity
Not available
๐ŸŽจ Colour
wit
๐Ÿ“Š Lower Explosive Limit
Not available
๐ŸงŠ Melting Point
ca. -4 C
Critical Property
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ”ฅ Flash Point
Het product is niet onderzocht.
Critical Property
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Odor Threshold
Geen relevante informatie beschikbaar.
๐Ÿ“Š Dynamic Viscosity
10 mPa.s
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ’ง Solubility
mengbaar met water
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ“Š Decomposition Temperature
Geen ontleding,wanneer de voorschriften/aanwijzingen voor opslag en gebruik in acht worden genomen.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Kinematic Viscosity
> 7 mm2/s
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Partition Coefficient
niet van toepassing voor mengsels
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Bulk Density
niet van toepassing
๐Ÿ“Š Physical State Data
liquid
๐Ÿ‘ƒ Odor
mild
๐Ÿ“Š Form
vloeibaar
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ“Š Solubility In Water
zwak oplosbaar
๐Ÿงช Physical State
vloeibaar
Critical Property
๐Ÿงช Ph
zwak basisch
๐Ÿ’จ Evaporation Rate
niet bepaald

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Adequate ventilation is required. Respiratory protection is needed in case of insufficient ventilation.

๐Ÿงค Hand Protection

Impermeable gloves made of synthetic rubber. Due to the wide variety of types, the manufacturer's instructions for use apply. Gloves must be checked regularly and before use, and replaced if necessary (e.g., small leaks).

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side shields (frame glasses) (e.g., EN 166).

๐Ÿ˜ท Respiratory Protection

Respiratory protection in case of insufficient ventilation. Combination filter for organic, inorganic, acidic inorganic, and alkaline gases/vapors (e.g., EN 14387 type ABEK).

๐Ÿฆบ Skin/Body Protection

Body protection should be chosen based on the handling and exposure. Wearing closed work clothing is recommended.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Niet van toepassing

๐Ÿ“ฆ Proper Shipping Name

Niet van toepassing

โš ๏ธ Transport Hazard Class

Niet van toepassing

๐Ÿ“‹ Packing Group

Niet van toepassing

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for MasterFinish RL 215?

The signal word for this substance is "no signal word".

What is the physical form of MasterFinish RL 215?

MasterFinish RL 215 is a vloeibaar with wit color. It has mild odor.

What is the solubility of MasterFinish RL 215?

mengbaar met water

What is MasterFinish RL 215 used for?

Product van bouwchemie

What is the melting point of MasterFinish RL 215?

The melting point is ca. -4 C and the boiling point is ca. 100 C.