NextSDS Logo
EC

ECO Interior 10

NO SIGNAL WORD vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ECO Interior 10

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Interieurreiniger voor professioneel gebruik

Overview

ECO Interior 10 commonly used interieurreiniger voor professioneel gebruik.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (geen)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Greenspeed company logo - Safety Data Sheet supplier organization

Greenspeed

undefined

P.O.Box 1250 2280 CG Rijswijk (ZH), NL

NL

+31703458737

+31703458942

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 70 245 245

BE

Emergency Contact

+31 30 274 88 88

NL

Uitsluitend voor professionele hulpverleners

Emergency Contact

+ 33 (0)1 45 42 59 59

FR

Emergency Contact

(+352) 8002-5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Natriumlaurylethersulfaat
EC: 500-234-8
68891-38-3 5% Hazardous
3-Butoxypropaan-2-ol
EC: 225-878-4
5131-66-8 5% Hazardous

Additional Information

Voor de volledige tekst van de H & R-zinnen die worden genoemd in deze rubriek, zie rubriek 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Rechtop laten zitten, frisse lucht, rust en naar ziekenhuis vervoeren.

Symptoms:

geen

Skin Contact

Verontreinigde kleding uittrekken, eerst spoelen met veel water, dan zonodig naar arts vervoeren.

Symptoms:

geen

Eye Contact

Eerst langdurig spoelen met water (contactlenzen verwijderen mits makkelijk mogelijk), dan naar arts brengen.

Symptoms:

roodheid

Ingestion/Swallowing

Mond laten spoelen, GEEN braken opwekken en onmiddellijk naar ziekenhuis vervoeren.

Symptoms:

diarree, hoofdpijn, buikkrampen, slaperigheid, braken

Immediate Medical Attention Required

Steeds zo spoedig mogelijk medisch advies inwinnen in geval van ernstige of aanhoudende stoornissen. Bij inslikken: onmiddellijk naar ziekenhuis vervoeren. Bij inademing: naar ziekenhuis vervoeren. Bij huidcontact: zonodig naar arts vervoeren. Bij oogcontact: dan naar arts brengen.

Medical Treatment

geen

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Appearance
Not available
Metal Corrosion
Not available
Decomposition Temperature
/
Relative Evaporation Rate
2,000
Solubility
Not available
Solidification Point
Not available
Voc Content
4,00 %
Vapor Density
Technisch onmogelijk
Ph
10,5
Solubility In Water
volledig oplosbaar
Lower Explosive Limit
1,100 %
Flash Point
/
Critical Property
Physical State
vloeibaar
Critical Property
Relative Density
1,013 kg/l
Flammability
Technisch onmogelijk
Solubility In Fat
Not available
Evaporation Rate
2,000
Cloud Point
Not available
Kinematic Viscosity
1 mm²/s
Physical State Data
liquid
Softening Point
Not available
Colour Intensity
Not available
Freezing Point
Not available
Upper Explosive Limit
8,700 %
Form
Not available
Properties Status
Not available
Vapor Pressure
2 332 Pa
Melting Point
0 °C
Critical Property
Odor
kenmerkend
Explosive Limits
Not available
Bulk Density
Not available
Crystallisation Point
Not available
Odor Threshold
Technisch onmogelijk
Density
Not available
Dynamic Viscosity
1 mPa.s
Partition Coefficient
Technisch onmogelijk
Molecular Weight
Not available
State Under Standard Conditions
vloeibaar
Boiling Point
100 °C — 199 °C
Critical Property
Colour
Not available
Auto Ignition Temperature
207 °C
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Eventueel gebruiken met voldoende afzuigventilatie.

Hand Protection

Met nitril-handschoenen (EN 374) hanteren. Minimale doorbraaktijd van > 480 minuten, dikte 0,35mm. Handschoenen voor gebruik goed controleren. Handschoenen netjes uittrekken zonder de buitenkant aan te raken met de blote hand. De geschiktheid voor een specifieke werkplek moet worden overlegd met de fabrikant van de beschermhandschoenen.

Eye Protection

Oogspoelfles met zuiver water binnen bereik houden. Nauw aansluitende veiligheidsstofbril. Een gelaatsscherm en beschermend pak dragen bij uitzonderlijke verwerkingsproblemen.

Respiratory Protection

Ademhalingsbescherming niet nodig. Bij hinderlijke blootstelling gebruik type ABEK Inhalatiebescherming: gasmaskers.

Skin/Body Protection

Ondoordringbare kleding, Het type beschermingsmiddelen is afhankelijk van de concentratie en hoeveelheid gevaarlijke stoffen op de betreffende werkplek. Een beschermend pak dragen bij uitzonderlijke verwerkingsproblemen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

niet van toepassing

Proper Shipping Name

Niet onderworpen aan ADR, IMDG, ICAO/IATA

Transport Hazard Class

niet van toepassing

Packing Group

niet van toepassing

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ECO Interior 10?

The signal word for this substance is "no signal word".

What is the physical form of ECO Interior 10?

ECO Interior 10 is a vloeibaar . It has kenmerkend odor.

What is ECO Interior 10 used for?

Interieurreiniger voor professioneel gebruik

What is the melting point of ECO Interior 10?

The melting point is 0 °C and the boiling point is 100 °C — 199 °C.