Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
PTFE-spray E-COLL commonly used su21 consumentengebruik: particuliere huishoudens / algemeen publiek / consumenten su22 professioneel gebruik: publiek domein (administratie, onderwijs, amusement, dienstverlening, ambachtslieden) glijmiddel/smeermiddel.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
E/D/E - Einkaufsbuero Deutscher Eisenhaendler GmbH
manufacturer
EDE Platz 1 D-42389 Wuppertal Germany
DE
+49 202 6096-0
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Giftinformationszentrum Mainz
+49 (6131) 19240
DE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| butaan EC: 203-448-7 | 106-97-8 | 25-50% | Hazardous |
| propaan EC: 200-827-9 | 74-98-6 | 10-25% | Hazardous |
| isobutaan EC: 200-857-2 | 75-28-5 | 2.5-10% | Hazardous |
Additional Information
De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
Voor verse lucht zorgen.
Skin Contact
Onmiddellijk met water en zeep afwassen en goed naspoelen.
Eye Contact
De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.
Ingestion/Swallowing
Drink zeer veel water en voer verse lucht aan. Onmiddellijk een dokter waarschuwen.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
Suitable Extinguishing Media
CO2, bluspoeder of waterstraal. Grotere brand met waterstraal bestrijden of met schuim, dat tegen alcohol bestand is.
Unsuitable Extinguishing Media
Krachtige waterstraal
Specific Fire Hazards
Geen verdere relevante informatie verkrijgbaar.
Fire Fighting Instructions
De aan gevaar blootgestelde tanks met watersproeistraal koelen.
Firefighter Protection Equipment
Ontploffings- en brandgassen niet inademen.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
Emergency Procedures
Beschermende kleding aantrekken. Niet beschermde personen op afstand houden. Voor voldoende ventilatie zorgen.
Environmental Precautions
Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
Handling Precautions
• Tanks vorzichtig openen en behandelen.
Storage Conditions
• Op een koele plaats bewaren.
• De overheidsbepalingen m.
• b.
• t.
• de opslag van drukgaspakkingen moeten in acht genomen worden.
• Tegen hitte en directe zonnestralen beschermen.
Fire Prevention Measures
Onststekingsbronnen op afstand houden - niet roken.
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Hand Protection
Aanbeveling: Veiligheidshandschoenen. Handschoenmateriaal: Nitrielrubber. Aanbevolen materiaaldikte: ≥ 0,4 mm. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.
Eye Protection
Nauw aansluitende veiligheidsbril
Respiratory Protection
Bij goede ventilatie niet noodzakelijk.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
Chemical Stability
Geen afbraak bij gebruik volgens voorschrift.
Reactivity
Geen verdere relevante informatie verkrijgbaar.
Hazardous Reactions
Geen gevaarlijke reacties bekend.
Conditions to Avoid
Geen verdere relevante informatie verkrijgbaar.
Incompatible Materials
Geen verdere relevante informatie verkrijgbaar.
Hazardous Decomposition Products
Geen gevaarlijke ontbindingsprodukten bekend.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
UN Number
UN1950
Packing Group
Niet van toepassing
ADR Transport Precautions
Waarschuwing: Gassen
IMDG Maritime Transport Precautions
Waarschuwing: Gassen
IATA Air Transport Precautions
Waarschuwing: Gassen
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for PTFE-spray E-COLL?
The signal word for this substance is "no signal word".
What is the physical form of PTFE-spray E-COLL?
PTFE-spray E-COLL is a aërosol with kleurloos color. It has karakteristiek odor.
What is PTFE-spray E-COLL used for?
SU21 Consumentengebruik: Particuliere huishoudens / algemeen publiek / consumenten SU22 Professioneel gebruik: Publiek domein (administratie, onderwijs, amusement, dienstverlening, ambachtslieden) Glijmiddel/smeermiddel
What is the melting point of PTFE-spray E-COLL?
The melting point is Niet bepaald. and the boiling point is Vanwege aerosol niet bruikbaar..