FINASOL MF

NO SIGNAL WORD SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
FINASOL MF
Product Code
J86

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Oplosmiddel, ontvettingsmiddel, verdunningsmiddel, enz.....

Overview

FINASOL MF is a vloeistof substance commonly used oplosmiddel, ontvettingsmiddel, verdunningsmiddel, enz......

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Asp. Tox.
Skin Irrit.
Eye Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

TOTAL Belgium

undefined

Handelsstraat 93 Rue du Commerce B-1040 BRUSSEL - BRUXELLES BELGIE

BE

++32 (0)2 288 99 33

++32 (0)2 288 32 60

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

sa TOTAL BELGIUM nv

+32 (0) 16.271.261

BE

NVIC (National Vergiftiging Informatie Centrum) : Antigif centrum

+ 32 (0) 70.245.245

BE

Brandwondencentrum Brussel

02/2686200

BE

Brandwondencentrum Antwerpen

03/2177595

BE

Brandwondencentrum Gent

09/2403490

BE

Brandwondencentrum Leuven

016/348750

BE

Brandwondencentrum Wallonië

071/448000

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Product op basis van een oplosmiddel

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Kerosine (aardolie), met waterstof ontzwaveld
EC: 265-184-9
64742-81-0 95% Hazardous
N/A N/A 5% Hazardous
Calcium (C10-C14) alkylbenzolsulfonaat
EC: 290-635-1
90194-26-6 2% Hazardous

Composition Notes

Zie sectie 16 voor verklaringen van R-zinnen :

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Het slachtoffer in de frisse lucht brengen en laten rusten. Als wordt vermoed dat het product in de longen terecht is gekomen (bijv. tijdens het braken), met spoed naar ziekenhuis overbrengen.

Symptoms:

Het inademen van rook, dampen of aërosols kan een zwakke irritatie van de luchtwegen veroorzaken.

Skin Contact

Onmiddellijk alle besmette en bespatte kleding uitdoen. Wassen met ruim water en zeep.

Eye Contact

Onmiddellijk en gedurende tenminste 15 minuten met ruim water wassen, waarbij de oogleden worden opengesperd.

Ingestion/Swallowing

Niet laten braken om het risico te voorkomen dat het product in de luchtwegen terecht komt. Niets te drinken geven.

Symptoms:

Mogelijk gevaar voor overgeven en diarree.

Immediate Medical Attention Required

BIJ ERNSTIGE VERSCHIJNSELEN DIENT MEN, ONMIDDELLIJK DE HULP VAN EEN ARTS OF EERSTE HULP IN TE ROEPEN. Als wordt vermoed dat het product in de longen terecht is gekomen (bijv. tijdens het braken), met spoed naar ziekenhuis overbrengen.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

koolzuur (CO2), droge chemicaliën, schuim.

Unsuitable Extinguishing Media

gebruik nooit een waterstraal dit kan het vuur verspreiden.

Specific Fire Hazards

Bij onvolledige verbranding en pyrolyse kunnen min of meer giftige gassen ontstaan zoals CO, CO2, diverse koolwaterstoffen, aldehyden, etc. alsmede roet. Inademing ervan is zeer gevaarlijk.

Firefighter Protection Equipment

Het dragen van een goed isolerend ademhalingtoestel is verplicht vanwege de grote hoeveelheid rook en gevaarlijke gassen.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Maatregelen na morsen / lekkage: - op de grond: Voorkom lekkages van het materiaal naar afvoersystemen en riolering. Verzamelen en opnemen met fysische middelen (oppompen, afschuimen, etc.). - op het water: Drijvende absorptiemiddelen en vervolgens bijeenbrengen en verwijderen met mechanische middelen. Indien het materiaal in een waterstroom of riolering terecht gekomen is, dienen de autoriteiten te worden verwittigd.

Environmental Precautions

Voorkom lekkages van het materiaal naar afvoersystemen en riolering.

Cleanup Methods

Verzamelen en opnemen met fysische middelen (oppompen, afschuimen, etc.). bijeenbrengen en verwijderen met mechanische middelen.

Cleanup Materials:

Drijvende absorptiemiddelen

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Softening Point
Not available
Metal Corrosion
Not available
Relative Density
Not available
Solidification Point
Not available
Kinematic Viscosity
2,0 - 2,4 mm2/s
Properties Status
Not available
Flash Point
> 66 ° C CC gesloten kop
Critical Property
Vapor Pressure
Not available
Cloud Point
Not available
Upper Explosive Limit
Not available
Ph
6,5
State Under Standard Conditions
Not available
Bulk Density
Not available
Odor
Typisch.
Density
810 kg/m3
Critical Property
Form
Not available
Freezing Point
Not available
Partition Coefficient
Not available
Melting Point
Not available
Explosive Limits
Not available
Dynamic Viscosity
Not available
Voc Content
Not available
Molecular Weight
Not available
Auto Ignition Temperature
Not available
Appearance
Vloeistof
Evaporation Rate
Not available
Colour Intensity
Not available
Solubility
Oplosbaar in een groot aantal gangbare oplosmiddelen.
Solubility In Water
Oplosbaar in water.
Decomposition Temperature
Not available
Crystallisation Point
Not available
Physical State Data
liquid
Solubility In Fat
Not available
Boiling Point
Not available
Odor Threshold
Not available
Vapor Density
Not available
Physical State
Not available
Colour
Kleurloos tot lichtgeel.
Lower Explosive Limit
Not available
Relative Evaporation Rate
Not available
Flammability
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Zorg voor voldoende ventilatie bij risico van damp, rook of aerosol.

Neem alle maatregelen om risico's zo veel mogelijk te beperken; in het bijzonder voor gebruikte en in gebruik zijnde producten.

Houdt brandbare materialen uit de buurt; bewaar het product niet in de buurt van etenswaren en dranken.

Vermijd elektrostatische oplading.

De installatie is zo ontwerpen dat wegspattende olie (bijvoorbeeld door breken van aansluitingen) niet in aanraking kan komen met hete metalen delen of elektrische contacten.

Storage Conditions

Opslag bij omgevingstemperatuur, beschermd tegen water, vocht en onwillekeurig welke ontstekingsbron.

Te vermijden: Opslag in weer en wind.

General Hygiene Measures

Bewaar het product niet in de buurt van etenswaren en dranken.

Fire Prevention Measures

Houdt brandbare materialen uit de buurt. Lege verpakkingen kunnen ontvlambare of explosieve dampen bevatten. Lappen die doordrenkt zijn met het product, papier of materialen die gebruikt zijn voor het absorberen van het uitgevloeide product, zijn brandgevaarlijk. Zorg ervoor dat er geen opeenhoping ontstaat. Verwijder ze onmiddellijk na gebruik en neem de veiligheid in acht.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Gebruik het product in een goed geventileerde atmosfeer. Indien in een gesloten ruimte wordt gewerkt zal een goede ventilatie nodig zijn, of een geschikt ademhalingsbeschermingsmiddel dragen.

Hand Protection

Koolwaterstoffenbestendige handschoenen. Aanbevolen stof: nitril , neopreen. De levensduur van eenzelfde type handschoenen kan sterk verschillen van fabrikant tot fabrikant. Om deze redenen moet de levensduur van de handschoenen bepaald worden door de fabrikant zelf. Het type te gebruiken handschoenen wordt bepaald door de gebruiksomstandigheden (ttz veelvuldig gebruik, temperatuur, duur en type van contact, ...) Vooraleer een type te kiezen, wordt er aangeraden deze door de gebruikers te laten testen.

Eye Protection

Veiligheidsbril indien risico op spatten.

Respiratory Protection

Gebruik om binnen te gaan een ademhalingstoestel dat goedgekeurd is voor organische dampen en nevel.

Skin/Body Protection

Indien noodzakelijk, gezichtsbescherming, laarzen, koolwaterstoffenbestendige bedrijfskleding, veiligheidsschoenen. Het is aan te raden hemden met lange mouwen te dragen. Draag geen ring, polshorloge of iets gelijkaardigs dat het product kan vasthouden en een huidreactie kan veroorzaken.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Product is stabiel bij normale temperaturen voor opslag, hantering en gebruik.

Reactivity

Geen gevaarlijke reacties gekend onder normale gebruiksvoorwaarden, zie technische fiche.

Hazardous Reactions

Geen gevaarlijke reacties gekend onder normale gebruiksvoorwaarden, zie technische fiche.

Conditions to Avoid

Warmtebronnen (temperaturen boven het vlampunt), vonken, ontstekingsbronnen, vlammen, elektrostatische oplading.

Incompatible Materials

Contact met sterke oxydatiemiddelen vermijden.

Hazardous Decomposition Products

Bij onvolledige verbranding en pyrolyse kunnen min of meer giftige gassen ontstaan zoals CO, CO2, diverse koolwaterstoffen, aldehyden, enz. alsmede roet.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for FINASOL MF?

The signal word for this substance is "no signal word".

What is the solubility of FINASOL MF?

Oplosbaar in een groot aantal gangbare oplosmiddelen.

What is FINASOL MF used for?