NextSDS Logo
Me

Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent

DANGER vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent
Product Code
20847
Chemical Name
Methanol, anhydrous
Synonyms
carbinol, MEOH, methyl hydroxide, monohydroxy methane

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2119433307-44

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
Chemische reagens Met inachtneming van de in de bijlage van dit veiligheidsblad opgenomen voorwaarden.
Uses Advised Against
Het product, als zodanig of als onderdeel van een mengsel, is niet bedoeld voor gebruik door consumenten (zoals gedefinieerd door de REACH-verordening).

Overview

Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent (CAS: 67-56-1 ) is a kleurloos substance commonly used chemische reagens met inachtneming van de in de bijlage van dit veiligheidsblad opgenomen voorwaarden..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 2 H225
Acute Tox. Category 3 H301 + H311 + H331
STOT SE Category 1 H370

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS06 GHS Hazard Pictogram: Acute toxicity hazard - Poisonous materials that can cause death or serious harm

GHS06

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Licht ontvlambare vloeistof en damp.
  • H301 + H311 + H331: Giftig bij inslikken, bij contact met de huid en bij inademing.
  • H370: Veroorzaakt schade aan organen.

Precautionary Statements

  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet<br>roken.
  • P260: Stof/rook/gas/nevel/damp/spuitnevel niet inademen.
  • P280: Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
  • P301 + P310: NA INSLIKKEN: onmiddellijk een ANTIGIFCENTRUM/arts/… raadplegen.
  • P403 + P233: Op een goed geventileerde plaats bewaren. In goed gesloten verpakking bewaren.
  • NA (mogelijke) blootstelling: Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

VWR International bv

distributor

Geldenaaksebaan 464 Postcode/plaats 3001 Leuven, Researchpark Haasrode 2020

BE

+32 (0) 16 385 011

+32 (0) 16 385 385

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

070/245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Methanol
EC: 200-659-6
67-56-1 Not specified Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Slachtoffer naar de frisse lucht brengen en warm en rustig houden. Bij irritatie van de ademhalingswegen arts consulteren. In elk geval van twijfel of indien symptomen optreden, medische hulp inroepen.

Symptoms:

Ademhalingsstoornissen.

Skin Contact

Vervuilde, gedrenkte kleding direct uittrekken. Huidverontreinigingen onmiddellijk afwassen.

Eye Contact

Direct voorzichtig en grondig met oogdouche of met water spoelen. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Oogarts consulteren. Een ANTIGIFCENTRUM/arts raadplegen.

Ingestion/Swallowing

Mond grondig met water spoelen. Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen. Nooit een bewustloze persoon of bij optredende krampen iets oraal toedienen.

Symptoms:

Misselijkheid, Acidose, Risico op blindheid.

Immediate Medical Attention Required

In elk geval van twijfel of indien symptomen optreden, medische hulp inroepen. Bij irritatie van de ademhalingswegen arts consulteren. Oogarts consulteren. Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen.

Medical Treatment

Symptomatische behandeling. Na inslikken: Dien 50 ml pure ethanol toe in een drinkbare concentratie.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

ABC-poeder, Kooldioxide (CO2), Droog zand, Stikstof

Unsuitable Extinguishing Media

Sterke waterstraal.

Specific Fire Hazards

Ontvlambare vloeibare stoffen. Risico op ontsteking. Brandbare giftige stoffen (vloeibaar) Bij brand kunnen irriterende, bijtende en/of giftige gassen ontstaan. Dampen kunnen met lucht een explosief mengsel vormen. Dampen kunnen zich over grote afstanden verspreiden en door onstekingbronnen tot ontsteking, vlaminslag of explosie worden gebracht. Gesloten containers kunnen barsten als druk en temperatuur stijgen.

Fire Fighting Instructions

Blusmaatregelen afstemmen op de omgeving. Op afstand blussen omwille van ontploffingsgevaar. Ter bescherming van personen en koeling van containers, in het gevarengebied watersproeistraal inzetten.

Firefighter Protection Equipment

In geval van brand en/of explosie inademen van rook vermijden. Ademhalingsapparatuur met perslucht en beschermingskleding dragen.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Het lek dichten als dat veilig gedaan kan worden. elementaire hulp, decontaminatie, symptomatische behandeling. Bij een grote brand en het vrijkomen van grote hoeveelheden: Evacueren. Op afstand blussen omwille van ontploffingsgevaar.

Small Spill Procedures

Laat verdampen als het veilig is om dit te doen of inperken en absorberen met aarde, zand of ander inert materiaal en breng dan over in geschikte containers voor terugwinning of verwijdering.

Large Spill Procedures

Indijken of afdammen voor latere verwijdering. Mechanisch opnemen en in geschikte containers verwijderen. Bij een grote brand en het vrijkomen van grote hoeveelheden: Evacueren. Op afstand blussen omwille van ontploffingsgevaar.

Environmental Precautions

Voorkom lozing in het milieu.

Cleanup Methods

Mechanisch opnemen en in geschikte containers verwijderen. Inperken en absorberen met aarde, zand of ander inert materiaal en breng dan over in geschikte containers voor terugwinning of verwijdering.

Cleanup Materials:

aarde, zand of ander inert materiaal

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

State Under Standard Conditions
Not available
Freezing Point
-98 °C
Decomposition Temperature
Niet van toepassing
Dynamic Viscosity
0,614 mPa*s (20 °C)
Relative Evaporation Rate
Not available
Odor Threshold
Not available
Upper Explosive Limit
36,5 % (v/v)
Vapor Pressure
128 hPa (20 °C)
Solidification Point
Not available
Partition Coefficient
-0,77 (20 °C)
Appearance
kleurloos
Voc Content
Not available
Flash Point
11 °C (closed cup)
Critical Property
Evaporation Rate
geen gegevens beschikbaar
Melting Point
-98 °C
Critical Property
Flammability
Licht ontvlambare vloeistof en damp.
Physical State
vloeibaar
Critical Property
Form
Not available
Solubility In Water
soluble (20 °C)
Density
0,7918 g/cm³ (20 °C)
Critical Property
Physical State Data
liquid
Crystallisation Point
Not available
Softening Point
Not available
Colour
kleurloos
Solubility
Not available
Relative Density
Not available
Lower Explosive Limit
5,5 % (v/v)
Cloud Point
Not available
Kinematic Viscosity
geen gegevens beschikbaar
Metal Corrosion
Not available
Ph
7 (20 °C)
Odor
karakteristiek
Properties Status
Not available
Bulk Density
geen gegevens beschikbaar
Molecular Weight
Not available
Colour Intensity
Not available
Vapor Density
Not available
Auto Ignition Temperature
455 °C (DIN 51794)
Solubility In Fat
Not available
Explosive Limits
Not available
Boiling Point
64,6 °C (1013 hPa)
Critical Property
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Persoonlijk beschermingsuitrusting gebruiken (zie rubriek 8).

Aanraking met de ogen en de huid vermijden.

vermijd inademing van het product.

Storage Conditions

Gesloten verpakking op een goed geventileerde plaats bewaren.

Van brandbare stoffen verwijderd houden/bewaren.

Tegen zonlicht beschermen.

Uit de buurt houden van warmtebronnen (b.

v.

hete oppervlakken), vonken en open vuur.

General Hygiene Measures

Voor werkpauze en werkeinde handen wassen. Aanraking met de ogen en de huid vermijden. Niet eten, drinken of roken tijdens gebruik. Oogdouche klaargezet en de plaats duidelijk gekenmerkt worden.

Fire Prevention Measures

Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Technische maatregelen en de toepassing van geschikte arbeidsmethoden hebben voorrang boven het gebruik van persoonlijke beschermingsuitrustingen. Bij open hanteren moeten installaties met plaatselijke afzuiging gebruikt worden.

Hand Protection

Bij de omgang met chemische werkstoffen mogen handschoenen die tegen chemicaliën beschermen met CE-kenmerk inclusief het viercijferige controlenummer, gedragen worden. Aanbevolen handschoenenfabrikaten DIN-/EN-normen: DIN EN 374 Bij gepland hergebruik handschoenen voor het uittrekken reinigen en goed geventileerd bewaren. Bij kortdurig huidcontact: Geschikt materiaal: NBR (Nitrilrubber), Dikte van het handschoenenmateriaal: 0,38 mm, Doordringtijd (maximale draagduur): -, Aanbevolen handschoenenfabrikaten: VWR 112-1381. Bij herhaald handcontact: Geschikt materiaal: Butylrubber, Dikte van het handschoenenmateriaal: 0,30 mm, Doordringtijd (maximale draagduur): > 480 min, Aanbevolen handschoenenfabrikaten: VWR 112-3779

Eye Protection

Bril met zijbescherming dragen DIN-/EN-normen: DIN EN 166. Aanbeveling: VWR 111-0432

Respiratory Protection

Adembescherming is noodzakelijk bij: aerosol- of nevelvorming. Geschikte ademhalingsapparatuur: Geheel-/half/kwartmasker (DIN EN 136/140). Aanbeveling: VWR 111-0206. Geschikt materiaal: AXP3. Aanbeveling: VWR 111-8932

Skin/Body Protection

Draag geschikte beschermende kleding. Bij het hanteren met chemische werkstoffen mag alleen beschermingskleding tegen chemicaliën met een CE-kermerk inclusief viercijferig controlenummer, gedragen worden.

Environmental Exposure Controls

geen gegevens beschikbaar

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Het product is chemisch stabiel onder standaard omgevingsvoorwaarden (kamertemperatuur).

Reactivity

Dit materiaal is onder normale omstandigheden niet reactief. Dampen kunnen met lucht een explosief mengsel vormen.

Hazardous Reactions

Vorming van explosieachtige mengsels met: Oxidatiemiddelen. Stikstofoxide (NOx) Chloraten Salpeterzuur Zwavelzuur. Exotherme reactie met: Reductiemiddel. Zuur Zuurhalogenide Alkaliën, geconcentreerd Heftige reactie met: Alkalimetalen Aardalkalimetaal Vorming van: Waterstof

Conditions to Avoid

UV-straling/zonlicht Hitte Vonken. Vlam

Incompatible Materials

Zuren Alkalimetalen Oxidatiemiddelen.

Hazardous Decomposition Products

Formaldehyde

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1230

Proper Shipping Name

METHANOL

Transport Hazard Class

3 (6.1)

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent known by?

Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent is also known as: carbinol, MEOH, methyl hydroxide, monohydroxy methane

What is the hazard signal word for Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?

The signal word for this substance is "danger".

What is the physical form of Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?

Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent is a vloeibaar appearing as kleurloos with kleurloos color. It has karakteristiek odor.

What is Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent used for?

Chemische reagens Met inachtneming van de in de bijlage van dit veiligheidsblad opgenomen voorwaarden.

What are the hazard statements for Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?

This substance has 3 hazard statements: H225: Licht ontvlambare vloeistof en damp. H301 + H311 + H331: Giftig bij inslikken, bij contact met de huid en bij inademing. H370: Veroorzaakt schade aan organen.

What is the melting point of Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?

The melting point is -98 °C and the boiling point is 64,6 °C (1013 hPa).