NextSDS Logo
Safety Data Sheet NL

Eco-Cip F (PR 056)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Eco-Cip F (PR 056)

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Voor het intern reinigen van machines in de levensmiddelenindustrie.

Manufacturers & Suppliers

E

Eco-Point Nederland B.V.

national supplier

Postbus 137 4660 AC Halsteren

+31-164-632555

E

Eco-Point b.v.b.a.

national supplier

Prins Boudewijnlaan 97 9100 Sint-Niklaas

+32-3-766.32.15

Emergency Contacts

NVIC (NL)

+31-30-2748888

Antigifcentrum (B)

+32-(0)70-245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 Veroorzaakt ernstige brandwonden.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

mengsel van detergenten, complexeermiddel en alkalische bestanddelen

Chemical Name CAS Number Concentration Hazardous
Natriumhydroxide EC: 215-185-5 1310-73-2 15 - 20% Yes
Alkylglucoside EC: 414-420-0 --- 1 - 5% Yes
Ontharders en water --- 80% No
Niet ionogene oppervlakteactieve stoffen --- 5% No
Fosonaat --- 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

niet van toepassing

Skin contact

Verwijder onmiddellijk alle verontreinigde kleding, was de huid met veel water en zeep. Raadpleeg altijd een arts. Reinig kleding voor gebruik.

Eye contact

Reinig ogen onmiddellijk en zo lang mogelijk met veel water. Oogleden moeten van de oogbal afgehouden worden om een zorgvuldige reiniging te verkrijgen. Raadpleeg altijd een arts.

Ingestion

mond spoelen met water, telkens uitspugen, drink enkele glazen water zonder braakneigingen op te wekken raadpleeg een arts.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Het product is niet brandbaar

Unsuitable media

Niet van toepassing

Specific hazards

Niet van toepassing

Firefighter Protection

Standaard uitrusting

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Vermijd dat product onverdund in het oppervlakte- en/of grondwater terecht komt

Cleanup methods

neutraliseren en opnemen met een absorptiemiddel of wegspoelen met water

Materials: absorptiemiddel

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

neem de gebruikelijke voorzorgsmaatregelen voor het werken met corrosieve reinigingsmiddelen

Storage

Verpakking goed gesloten houden. Opslaan conform nationale richtlijnen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

normale ventilatie

Hands

draag rubber handschoenen

Eyes

veiligheidsbril dragen

Respiratory

niet van toepassing/ normale ventilatie

Skin/Body

draag geschikte beschermende kleding

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
vloeibaar
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Licht geel
Colour Intensity
---
Form
---
Odor
neutraal
Odor Threshold
---
Ph
14
Melting Point
ca. 0 °C
Boiling Point
ca. 109 °C
Flash Point
niet brandbaar
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
niet bekend
Vapor Density
niet bekend
Relative Density
1,16 g/ml
Bulk Density
---
Density
---
Flammability
niet brandbaar
Upper Explosive Limit
geen
Lower Explosive Limit
geen
Explosive Limits
---
Auto Ignition Temperature
geen
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Afval van residuen/ niet- gebruikte producten

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1824
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Voor het intern reinigen van machines in de levensmiddelenindustrie.

Chemical Safety Assessment Not performed

Indeling gebaseerd op calculatiemethode. Bevat R35 (veroorzaakt ernstige brandwonden) en bijbehorende S-zinnen (S2, S26, S27, S37/39).

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Eco-Cip F (PR 056)?

The signal word is danger.

What is the physical form of Eco-Cip F (PR 056)?

Eco-Cip F (PR 056) is a vloeibaar with licht geel color. It has neutraal odor.

What is Eco-Cip F (PR 056) used for?

Voor het intern reinigen van machines in de levensmiddelenindustrie.

What are the hazard statements for Eco-Cip F (PR 056)?

This substance has 1 hazard statement:

  • H314: Veroorzaakt ernstige brandwonden.

What is the melting point of Eco-Cip F (PR 056)?

The melting point is ca. 0 °C and the boiling point is ca. 109 °C.