NextSDS Logo
Safety Data Sheet NL

Relca-TOP-3101 liq 0120

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Relca-TOP-3101 liq 0120
Product Code
252500

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industriele sector: Drukinkt- en coatingindustrie; Gebruikstype: Coating

Manufacturers & Suppliers

S

Stahl Leinfelden GmbH

manufacturer

Benzstraße 11, 70771 Leinfelden-Echterdingen

+49 711 90320

Emergency Contacts

Emergency Contact

+44 (0) 1235 239 670

24 h

Antigifcentrum

+32 70 245 245

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Polyacrylzuur derivaat, waterige dispersie

Chemical Name CAS Number Concentration Hazardous
Polyacrylzuur derivaat --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Slachtoffer in de frisse lucht brengen. Indien symptomen aanhouden, een arts raadplegen.

Skin contact

BIJ CONTACT MET DE HUID: met veel water en zeep wassen.

Eye contact

Bij aanraking met de ogen onmiddellijk grondig spoelen met veel water gedurende minstens 15 minuten.

Ingestion

Mond spoelen met water. Onmiddellijk medische hulp inroepen.

Immediate Medical Attention

Onmiddellijk medische hulp inroepen.

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Watersproeistraal, Droogpoeder, Kooldioxide (CO2), Alcoholbestendig schuim

Specific hazards

Door thermische ontbinding kunnen acrylmonomeren opleveren.

Firefighter Protection

Persluchtadembescherming

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Het product mag niet wegvloeien in riool, waterstroom of bodem.

Cleanup methods

Opnemen in inert absorberend materiaal

Materials: inert absorberend materiaal (b.v. zand, kiezelgur, zuurbindingsmiddel, universeel bindingsmiddel, zaagsel)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

De gebruikelijke voorzorgsmaatregelen bij omgang met chemicaliën zijn in acht te nemen

Storage

Tegen vorst beschermen. Na invriezen is het product niet meer bruikbaar. Verwijderd houden van warmte.

Hygiene

Handen wassen voor elke werkonderbreking en aan het einde van de werkdag. Verontreinigde kleding onmiddellijk uittrekken en wassen alvorens deze opnieuw te gebruiken.

Fire prevention

Het product is moeilijk brandbaar, niet oxiderend, niet zelfontbrandend, niet ontploffingsgevaarlijk.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gebruik CE goedgekeurde beschermingshandschoenen, bestendig tegen chemikalien

Eyes

Veiligheidsbril b.v. bij het vullen en bij het reinigen van toestellen.

Respiratory

Ademhalingsapparaat alleen nodig indien er aërosol of nevel gevormd is.

Skin/Body

Draag geschikte beschermende kleding.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Physical State Data
liquid
Dynamic Viscosity
niet bepaald.
Ph
6,0 - 8,0
Melting Point
Niet uitgevoerd
State Under Standard Conditions
---
Evaporation Rate
---
Relative Density
---
Physical State
vloeibaar
Decomposition Temperature
niet van toepassing
Solubility In Water
mengbaar
Molecular Weight
---
Kinematic Viscosity
---
Softening Point
---
Solidification Point
---
Form
---
Metal Corrosion
---
Odor Threshold
---
Auto Ignition Temperature
niet van toepassing
Appearance
---
Crystallisation Point
---
Colour Intensity
---
Vapor Density
---
Freezing Point
---
Explosive Limits
---
Bulk Density
---
Boiling Point
100 °C
Solubility In Fat
---
Lower Explosive Limit
niet van toepassing
Odor
kenmerkend
Vapor Pressure
niet bepaald.
Relative Evaporation Rate
---
Partition Coefficient
Deze eigenschap is niet van toepassing op mengsels.
Flammability
---
Voc Content
---
Properties Status
---
Flash Point
geen vlampunt tot aan het kookpunt
Upper Explosive Limit
niet van toepassing
Density
0,98 g/cm3 (20 °C)
Solubility
---
Colour
wit
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale omstandigheden.

Reactivity

zie paragraaf 10.3. "Kans op gevaarlijke reacties"

Hazardous reactions

Onder normale gebruiksomstandigheden zijn geen gevaarlijke reacties waargenomen.

Avoid

Niet bekend

Incompatible

Niet bekend

Decomposition

Bij beroepsmatige hantering en opslag zijn ons geen gevaarlijke ontledingsproducten bekend.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Relca-TOP-3101 liq 0120?

The signal word is no signal word.

What is the physical form of Relca-TOP-3101 liq 0120?

Relca-TOP-3101 liq 0120 is a vloeibaar with wit color. It has kenmerkend odor.

What is Relca-TOP-3101 liq 0120 used for?

Industriele sector: Drukinkt- en coatingindustrie; Gebruikstype: Coating

What is the melting point of Relca-TOP-3101 liq 0120?

The melting point is Niet uitgevoerd and the boiling point is 100 °C.