NextSDS Logo
Safety Data Sheet NL

MOLYKOTE(R) G-RAPID PLUS PASTE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOLYKOTE(R) G-RAPID PLUS PASTE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Smeermiddelen en toevoegingen

Manufacturers & Suppliers

D

Dow Corning S.A.

manufacturer

rue Jules Bordet - Parc Industriel - Zone C B-7180 Seneffe België

D

Dow Corning Central Europe

regional supplier

+49 6112371

D

Dow Corning Northern Europe

regional supplier

+44 1676528000

D

Dow Corning Southern Europe

regional supplier

+33 472841360

Emergency Contacts

Dow Corning (Barry U.K. 24h)

+44 1446732350

24h

Dow Corning (Wiesbaden 24h)

49 61122158

24h

Dow Corning (Seneffe 24h)

+32 64 888240

24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mengsel van anorganische en organische verbindingen.

Chemical Name CAS Number Concentration Hazardous
Witte paraffineolie (aardolie) EC: 232-455-8 8042-47-5 47% Yes
Calciumdihydroxide EC: 215-137-3 1305-62-0 20% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In frisse lucht brengen.

Skin contact

Spoelen met water.

Eye contact

Spoelen met water.

Ingestion

In normale omstandigheden is geen eerste hulp vereist.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Kooldioxide, schuim, droog poeder of waternevel. Water kan gebruikt worden om aan het vuur blootgestelde containers af te koelen.

Unsuitable media

Geen bekend.

Specific hazards

Geen bekend.

Instructions

Houd de containers koel door water te sproeien tot nog enige tijd nadat het vuur geblust is.

Firefighter Protection

Een onafhankelijk ademhalingstoestel en beschermende kleding dragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Laat geen grote hoeveelheden in de riool of in oppervlaktewater lopen.

Cleanup methods

Opschrapen en in een vuilnisvat met deksel deponeren. Het gemorste product veroorzaakt een uiterst glad oppervlak.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Aanraking met de huid en ogen vermijden.

Storage

Houdt buiten bereik van water of vocht.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Afzuiging : Zie sectie 7.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Pasta
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Pasta
Colour
Zwart
Colour Intensity
---
Form
Pasta
Odor
weinig
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
> 200 °C (Closed Cup)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
1,4
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale omstandigheden.

Avoid

Geen gegevens.

Incompatible

Kan met sterke oxidatiemiddelen reageren.

Decomposition

Bij thermische afbraak van deze stof tijdens brand of onder extreem hete omstandigheden kunnen de volgende ontledingsproducten vrijkomen: Kooldioxide en sporen van onvolledig verbrande koolstofproducten. Bij thermische ontbinding kan formaldehyde worden gevormd. Zwavelproducten.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOLYKOTE(R) G-RAPID PLUS PASTE?

The signal word is no signal word.

What is the physical form of MOLYKOTE(R) G-RAPID PLUS PASTE?

MOLYKOTE(R) G-RAPID PLUS PASTE is a pasta appearing as pasta with zwart color. It has weinig odor.

What is MOLYKOTE(R) G-RAPID PLUS PASTE used for?

Smeermiddelen en toevoegingen