NextSDS Logo
Safety Data Sheet NL

RADGLO RS-13 ORANGE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADGLO RS-13 ORANGE

Regulatory Identifiers

CAS Number
N/A
REACH No.
Componenten zijn gepreregistreerd volgens 1907/2006/EC

Identified Uses

Fluorescerend pigment voor de aanmaak van verven, drukinkten en coatings.

Manufacturers & Suppliers

R

RADIANT COLOR NV

manufacturer

Europark 1046 B-3530 HOUTHALEN België

Emergency Contacts

Emergency Contact

+32 11 52 07 40

maandag tot vrijdag 09h00 -17h00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Polycondensatiehars opgebouwd uit melamine, paraformaldehyde en tolueensulfonamide, ingekleurd met synthetische kleurstoffen.

Chemical Name CAS Number Concentration Hazardous
Formaldehyde EC: 200-001-8 50-00-0 0.1% Yes
Xanthene dye EC: 221-326-1 3068-39-1 0.1 - 0.5% Yes
Benzophenone compound EC: 205-031-5 131-57-7 1 - 1.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In de frisse lucht brengen. Raadpleeg een arts na een belangrijke blootstelling.

Skin contact

Wassen met water en zeep.

Eye contact

Spoelen met water terwijl men het ooglid open houdt. Een arts raadplegen wanneer de irritatie aanhoudt.

Ingestion

Mond spoelen met water. Een arts raadplegen bij belangrijke blootstelling.

Immediate Medical Attention

Een arts raadplegen wanneer de irritatie aanhoudt. Raadpleeg een arts na een belangrijke blootstelling.

Medical Treatment

Behandel de symptomen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Waterstraal / Waternevel / Schuim / Poeder / CO2

Unsuitable media

Geen specifieke beperkingen

Specific hazards

Fijn verdeeld product in de lucht kan een stofexplosie veroorzaken. De rook die bij verbranding vrijkomt kan toxisch zijn.

Firefighter Protection

Autonome adembeschermingsapparatuur dragen in geval van brand.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet in het afvalwater laten komen.

Cleanup methods

Opnemen met zand of een ander absorberend middel. Verwijderen als ander stofafval.

Materials: zand of een ander absorberend middel

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

De normale voorzorgen bij het omgaan met chemicalïen in acht nemen.

Storage

Droog en koel bewaren. De verpakking gesloten houden.

Fire prevention

Voorzorgen nemen tegen electrostatische ontladingen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

NBR-handschoenen conform EN 388

Eyes

Veiligheidsbril volgens EN 166

Respiratory

Stofmasker klasse 2, confrom EN 149

Skin/Body

Goed gesloten kledij

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
---
Vapor Density
Niet van toepassing
Voc Content
---
Molecular Weight
---
Vapor Pressure
Niet van toepassing
Partition Coefficient
Niet van toepassing (niet onlosbaar in water en n-octanol)
Kinematic Viscosity
---
Dynamic Viscosity
---
Freezing Point
---
Ph
7,0-10,5 (5g in 100 cc water met benattingsmiddel)
Relative Density
1.38 g/ml
Evaporation Rate
Niet van toepassing (vaste stof)
Decomposition Temperature
Geen gegevens bekend.
Physical State
Poeder
Bulk Density
---
Solubility In Fat
Niet oplosbaar
Metal Corrosion
---
Lower Explosive Limit
---
Physical State Data
solid
Cloud Point
---
Boiling Point
Niet van toepassing
Melting Point
Geen gegevens bekend.
Explosive Limits
---
Density
---
State Under Standard Conditions
---
Odor
Lichte aldehyde geur
Relative Evaporation Rate
---
Solidification Point
---
Odor Threshold
---
Flash Point
Niet van toepassing
Auto Ignition Temperature
Geen gegevens bekend.
Solubility In Water
Niet oplosbaar
Properties Status
---
Crystallisation Point
---
Appearance
Poeder
Solubility
a) in water Niet oplosbaar b) in vet Niet oplosbaar
Softening Point
---
Flammability
Niet van toepassing
Colour
Oranje
Colour Intensity
---
Form
Poeder
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen gegevens bekend.

Reactivity

Geen gegevens bekend.

Hazardous reactions

Geen gegevens bekend.

Avoid

Overmatige stofvorming in de buurt van open vlam/vonken. Overmatige warmte.

Incompatible

Contact met sterke oxidantia

Decomposition

Verbrandingsproducten bevatten stikstof, zwavel - en koolstofoxiden.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADGLO RS-13 ORANGE?

The signal word is no signal word.

What is the physical form of RADGLO RS-13 ORANGE?

RADGLO RS-13 ORANGE is a poeder appearing as poeder with oranje color. It has lichte aldehyde geur odor.

What is the solubility of RADGLO RS-13 ORANGE?

a) in water Niet oplosbaar b) in vet Niet oplosbaar

What is RADGLO RS-13 ORANGE used for?

Fluorescerend pigment voor de aanmaak van verven, drukinkten en coatings.

What is the melting point of RADGLO RS-13 ORANGE?

The melting point is Geen gegevens bekend. and the boiling point is Niet van toepassing.