NextSDS Logo
Safety Data Sheet NL

Lastek 61

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lastek 61

Regulatory Identifiers

CAS Number
N/A

Identified Uses

beklede elektrode voor lassen van koper en koperlegeringen

Manufacturers & Suppliers

L

Lastek Belgium n.v.

manufacturer

Industriepark Wolfslee, Toekomstlaan 50 – 2200 Herentals

014/22.57.67

Emergency Contacts

Emergency Contact

014/22.57.67

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Kerndraad: koper, tin Bekleding: basisch, bevat fluoride

Chemical Name CAS Number Concentration Hazardous
koper --- --- No
tin --- --- No
bekleding --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bij overmatig inademen van lasrook de persoon in frisse lucht brengen.

Skin contact

Bij verbranding overvloedig met koud water spoelen.

Immediate Medical Attention

Bij aanhouden van irritatie of optreden van andere symptomen arts raadplegen. Bij verbranding eventueel arts opzoeken.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

nvt

Unsuitable media

nvt

Firefighter Protection

nvt

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

nvt

Cleanup methods

nvt

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

nvt

Storage

nvt

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

bij het lassen moeten gepaste voorzorgen getroffen worden zoals: zorgen voor een efficiënte en voldoende lasrookafzuiging, verluchting van de werkplaats

Skin/Body

geschikte laskleding en -uitrusting

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
bronzen draad met donkere bekleding
Colour
bronzen draad met donkere bekleding
Colour Intensity
---
Form
vaal
Odor
geen
Odor Threshold
---
Ph
nv
Melting Point
ca. 1050°C
Boiling Point
nv
Flash Point
nv
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
nv
Vapor Density
---
Relative Density
8.3 g/cm³
Bulk Density
---
Density
8.3 g/cm³
Flammability
---
Upper Explosive Limit
nv
Lower Explosive Limit
nv
Explosive Limits
---
Auto Ignition Temperature
nv
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
n/h
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

stabiel

Avoid

geen

Incompatible

vermijd contact met sterke zuren, basen en oxiderende reagentia

Decomposition

deze elektroden vormen geen schadelijke dampen of rook bij normale omgevingstemperatuur. Tijdens hun gebruik wordt lasrook ontwikkeld (zie sect. 8)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lastek 61?

The signal word is no signal word.

What is the physical form of Lastek 61?

Lastek 61 is a solid appearing as bronzen draad met donkere bekleding with bronzen draad met donkere bekleding color. It has geen odor.

What is Lastek 61 used for?

beklede elektrode voor lassen van koper en koperlegeringen

What is the melting point of Lastek 61?

The melting point is ca. 1050°C and the boiling point is nv.